CLEARANCES TO COMBUSTIBLES 6039(T)
The stove must be installed with the following minimum clearances to side and back wall combustible materials.
NOTE: These are minimum clearances to combustible walls established by the testing lab.
PARALLEL - A - Sidewall to Top Edge of Unit
8 in./203mm
B - Sidewall to Flue
13 in./330mm
C - Backwall to Flue
3 in./75mm
D - Backwall to Unit
9 in./228mm
CORNER - E - Adjacent Wall to Flue
3 in./75mm
F - Adjacent Wall to Unit
4 in./100mm
BACK WALL
SIDE WALL
SIDE WALL
Backwall / Sidewall
Parallel
BACK WALL
Corner Installation
NOTE:
Allow sufficient space to remove the left and right side panels for maintenance purposes.
6”
min.
HEARTH PROTECTION