INSTALLATION

INSTALLATION OPTIONS

Freestanding Unit - 

supported by pedestal/legs 

and  placed  on  a  non-combustible  floor  surface 

in  compliance  with  clearance  requirements  for  a 

freestanding stove installation.

Alcove Unit - 

supported by pedestal/legs and 

placed  on  a  non-combustible  floor  surface  in 

compliance  with  clearance  requirements  for  an 

alcove installation.

IMPROPER INSTALLATION

The  use  of  other  components  other  than  stated 

herein  could  cause  bodily  harm,  heater  damage, 

and void your warranty. The manufacturer will not 

be held responsible for damage caused by the 

malfunction of a stove due to improper venting or 

installation.

FLOOR PROTECTION

This  unit  must  be  installed  on  a  non-combustible 

floor  surface.  If  a  floor  pad  is  used,  it  should  be 

certified or equal. The floor pad or non-combustible 

surface  should  be  large  enough  to  extend  a 

minimum  of  6”  (153  mm)  in  front,  6”  (153  mm)  on 

each  side,  and  1”  (26  mm)  behind  the  stove.  Floor 

protection  must  extend  under  and  2”  (51  mm)  to 

each side of the chimney tee for an interior vertical 

installation. A Floor Protector of 1” (26 mm) thick is 

recommended for this installation.

D

B

C

B

A

A

Rear (through wall)

1”

25 mm

B

Side

6”

152 mm

C

Front

6”

152 mm

D

Rear (interior 

vertical)

2”

50 mm

CLEARANCES

Your  pellet  stove  has  been  tested  and  listed  for 

installation in residential, mobile home, and alcove 

applications in accordance with the clearances 

given in this manual. NOTE: The distance on the side 

of your pellet stove may need to be greater than the 

minimum required clearance for suitable access to 

the control panel. For safety reasons, please adhere 

to the installation clearances and restrictions. Any 

reduction in clearance to combustibles may only be 

done by means approved by a regulatory authority.

F

G

E

H

F

G

J

J

J

J

K

PARALLEL

E Backwall to unit

9.5” 241 mm

F Sidewall to flue

14” 330 mm

G Sidewall to top edge 

of unit

8” 203 mm

H Backwall to flue

3”

76.2mm

CORNER J Adjacent wall to unit 8” 203 mm

ALCOVE

K Alcove depth

36” 914 mm

Содержание KP5522

Страница 1: ...2 P AP5622 L AP5622 W VG5722 VG5722 P VG5722 L VG5722 W SP1100 SP1100 W Type Pellet Fired Room Heater March 29 2022 Revised Date May 17 2022 ASTM E2779 Standard Test Method for Determining Particulate...

Страница 2: ...Date March 29 2022 Original Issue Date May 17 2022 The following changes were made per request from EPA B415 Calculations page was included in Appendix A see page 73 of Non CBI report Adjusted CO emis...

Страница 3: ...Conditions Summary 8 Appliance Operation and Test Settings 8 Settings Run Notes 8 Appliance Description 9 Appliance Dimensions 9 Test Fuel Properties 12 Pellet Fuel Analysis 13 Sampling Location and...

Страница 4: ...vironmental Protection Agency for the certification and auditing of wood heaters pursuant to subpart AAA of 40 CFR Part 60 New Source Performance Standards for Residential Wood Heaters and subpart QQQ...

Страница 5: ...n Button Notes Prior to start of testing 50 hours of conditioning was performed by US Stove personnel at a medium burn setting per ASTM E2779 Prior to start of testing the dilution tunnel was cleaned...

Страница 6: ...Stove Company Catalyst No Heat exchange blower Integral Type Pellet Stove Style Free Standing Date Received Monday February 14 2022 Testing Period Start Friday February 18 2022 Finish Friday February...

Страница 7: ...Equipment ID Equipment Description 190 Mettler Toledo 3 x3 floor scale w digital weight indicator 129 APEX XC 50 DIR Digital Emissions Sampling Box A 130 APEX XC 50 DIR Digital Emissions Sampling Box...

Страница 8: ...ter meets the 2020 PM emission standard of 2 0 g hr per CFR 40 part 60 60 532 b Detailed individual run data can be found in Appendix A submitted with this report Summary Table EPA Application Table R...

Страница 9: ...or all runs fell within allowable specifications of ASTM E2779 and ASTM E2515 A summary of facility conditions fuel burned and run times is listed below Runs Ambient F Relative Humidity Average Barome...

Страница 10: ...exception of the brand names Appliance Type Pellet Fired Room Heater Air Introduction System Air enters the burn chamber by being pulled though the firepot via the exhaust blower see air flow diagram...

Страница 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...

Страница 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...

Страница 13: ...53 Model KP5522 Page 12 Test Fuel Properties Test fuel used was Bear Mountain Wood Pellet Fuel a PFI Certified Premium Pellet Brand A sample of pellets was sent to Twin Ports Testing for analysis see...

Страница 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...

Страница 15: ...16 5 feet downstream from any disturbances and 2 feet upstream from any disturbances Flow rate traverse data was collected 8 feet downstream from any disturbances and 4 feet upstream from any disturba...

Страница 16: ...hours and then weighed at 6 hour intervals to a constant weight per ASTM E2515 11 Section 10 Calibration Quality Control and Assurances Calibration procedures and results were conducted per EPA Method...

Страница 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...

Страница 18: ...e been submitted electronically in conjunction with this report Appendix A Test Run Data Technician Notes and Sample Analysis Appendix B Labels and Manuals Appendix C Equipment Calibration Records App...

Страница 19: ...32 369 N A 33 368 N A 34 373 N A 35 369 N A 36 375 N A 37 378 N A 38 372 N A 39 373 N A 40 371 N A 41 366 N A 42 369 N A 43 366 N A 44 378 N A 45 376 N A 46 387 N A 47 387 N A 48 380 N A 49 380 N A 5...

Страница 20: ...O R H E E S V P P R O D U C T C O M P L I A N C E C 503 887 4566 E johnv usstove com U N I T E D S T A T E S S T O V E C O M P A N Y 227 Industrial Park Road South Pittsburg Tennessee 37380 USA usstov...

Страница 21: ...PELLET TEST DATA PACKET ASTM E2779 E2515 Run 1 Data Summary Client USSC Test Date Tracking Job Model Techician Signature Date 3 9 2022 KP5522 22 753 121 2 18 2022 PFS TECO...

Страница 22: ...urn Rate Target TEST RESULTS ASTM E2779 ASTM E2515 Average Gas Meter Temperature F Total Sample Volume dscf Average Tunnel Temperature F Total Sample Volume ft3 Average Gas Velocity in Dilution Tunnel...

Страница 23: ...08 Btu h Burn Rate kg h 1 39 3 06 lb h Input kJ h 27 248 25 848 Btu h Test Load Weight dry kg 8 32 18 35 dry lb MC wet 4 19 MC dry 4 37 Particulate g 8 99 CO g 55 Test Duration h 6 00 Emissions Partic...

Страница 24: ...91 Btu h Burn Rate kg h 2 26 4 99 lb h Input kJ h 44 480 42 194 Btu h Test Load Weight dry kg 2 26 4 99 dry lb MC wet 4 19 MC dry 4 37 Particulate g N A CO g 12 Test Duration h 1 00 Emissions Particul...

Страница 25: ...Btu h Burn Rate kg h 1 58 3 47 lb h Input kJ h 30 948 29 357 Btu h Test Load Weight dry kg 3 15 6 95 dry lb MC wet 4 19 MC dry 4 37 Particulate g N A CO g 21 Test Duration h 2 00 Emissions Particulat...

Страница 26: ...0 Btu h Burn Rate kg h 0 97 2 14 lb h Input kJ h 19 038 18 060 Btu h Test Load Weight dry kg 2 91 6 41 dry lb MC wet 4 19 MC dry 4 37 Particulate g N A CO g 22 Test Duration h 3 00 Emissions Particula...

Страница 27: ...n 11 0 020 68 12 0 014 68 Center 0 030 68 Static Pressure 0 043 in H2O Fuel Type D Fir Oak Pellet Brand HHV kJ kg 19 810 19 887 Pellet Fuel Grade C 48 73 50 HHV BTU lb H 6 87 6 6 C O 43 9 42 9 H Ash 0...

Страница 28: ...0 070 301 67 22 42 0 0 13 0 080 301 67 23 41 9 0 11 0 070 303 67 24 41 8 0 09 0 080 304 67 25 41 7 0 08 0 070 306 67 26 41 6 0 12 0 070 306 67 27 41 6 0 06 0 070 306 67 28 41 5 0 1 0 070 309 68 29 41...

Страница 29: ...6 0 070 316 68 49 39 6 0 11 0 070 315 68 50 39 6 0 07 0 070 315 68 51 39 5 0 08 0 070 314 68 52 39 4 0 08 0 080 315 68 53 39 3 0 1 0 070 316 68 54 39 2 0 1 0 070 316 68 55 39 1 0 08 0 070 315 68 56 39...

Страница 30: ...2 14 2 636 0 187 0 030 1 47 68 7 1 52 99 17 9 0 1 87 317 72 67 7 15 2 824 0 188 0 029 1 48 68 5 1 49 102 17 9 0 0 87 316 72 67 3 16 3 011 0 187 0 031 1 48 68 2 1 57 98 17 8 0 1 88 316 72 67 4 17 3 19...

Страница 31: ...5 1 0 1 88 317 74 69 1 47 8 779 0 186 0 031 1 45 67 4 1 54 98 15 1 0 1 88 316 74 69 3 48 8 964 0 185 0 031 1 45 67 3 1 5 97 15 0 0 0 88 315 74 69 2 49 9 150 0 186 0 030 1 46 67 4 1 45 99 14 9 0 1 88 3...

Страница 32: ...12 8 0 1 85 276 72 69 6 81 15 190 0 190 0 030 1 50 65 7 1 36 101 12 7 0 1 85 275 72 69 4 82 15 380 0 190 0 031 1 49 65 8 1 52 100 12 6 0 1 85 276 72 69 5 83 15 569 0 189 0 031 1 49 65 7 1 46 99 12 6 0...

Страница 33: ...10 7 0 1 85 273 73 70 1 115 21 648 0 190 0 031 1 50 65 1 1 58 100 10 6 0 1 85 273 73 69 8 116 21 838 0 190 0 031 1 50 65 1 37 100 10 6 0 1 85 273 73 69 8 117 22 029 0 191 0 031 1 50 64 8 1 58 100 10 5...

Страница 34: ...5 1 36 101 8 7 0 1 85 270 73 69 9 149 28 099 0 189 0 032 1 49 64 4 1 42 98 8 6 0 1 85 271 73 69 9 150 28 288 0 189 0 031 1 49 64 4 1 63 99 8 5 0 1 85 272 73 69 9 151 28 477 0 189 0 031 1 49 64 3 1 46...

Страница 35: ...61 5 1 62 98 6 6 0 0 84 253 73 68 4 183 34 535 0 189 0 032 1 49 61 3 1 46 98 6 6 0 0 83 249 73 68 1 184 34 724 0 189 0 031 1 46 61 1 1 58 100 6 6 0 0 83 244 73 68 185 34 913 0 189 0 031 1 49 60 9 1 3...

Страница 36: ...1 47 102 5 3 0 1 80 212 71 67 2 217 40 962 0 189 0 032 1 49 59 1 59 98 5 3 0 1 80 213 71 67 1 218 41 150 0 188 0 031 1 48 59 1 63 100 5 3 0 0 80 213 71 67 1 219 41 339 0 189 0 031 1 48 58 9 1 66 100 5...

Страница 37: ...4 1 0 0 81 213 70 67 1 251 47 366 0 188 0 031 1 47 59 4 1 44 99 4 1 0 0 81 208 71 67 2 252 47 556 0 190 0 031 1 47 59 4 1 59 101 4 0 0 1 81 207 70 67 2 253 47 744 0 188 0 031 1 47 59 4 1 56 99 4 0 0...

Страница 38: ...1 58 103 2 9 0 0 81 209 71 67 2 285 53 853 0 191 0 031 1 52 59 7 1 68 101 2 8 0 0 81 208 71 67 2 286 54 045 0 192 0 031 1 51 59 8 1 48 102 2 8 0 0 81 208 71 67 3 287 54 236 0 191 0 031 1 51 59 7 1 66...

Страница 39: ...102 1 6 0 0 81 213 71 67 7 319 60 343 0 191 0 030 1 49 60 1 64 103 1 5 0 0 81 211 71 67 5 320 60 535 0 192 0 030 1 49 59 8 1 59 103 1 5 0 0 81 209 71 67 4 321 60 725 0 190 0 030 1 50 60 1 52 102 1 5 0...

Страница 40: ...100 0 5 0 0 81 212 71 67 5 347 65 663 0 189 0 031 1 49 60 3 1 67 100 0 5 0 0 81 210 71 67 5 348 65 853 0 190 0 030 1 49 60 5 1 6 102 0 5 0 0 81 208 71 67 5 349 66 042 0 189 0 030 1 47 60 5 1 63 101 0...

Страница 41: ...175 1 47 71 2 1 54 104 70 0 070 9 03 0 05 15 2 630 0 173 1 45 71 4 1 32 104 70 0 070 6 49 0 04 16 2 803 0 173 1 47 71 6 1 32 101 70 0 080 7 69 0 03 17 2 978 0 175 1 48 71 9 1 31 102 71 0 080 7 69 0 0...

Страница 42: ...16 0 04 45 7 814 0 172 1 47 79 7 1 55 100 71 0 080 7 06 0 04 46 7 987 0 173 1 45 80 1 51 99 71 0 080 7 07 0 04 47 8 159 0 172 1 42 80 2 1 36 99 70 0 080 6 27 0 04 48 8 331 0 172 1 45 80 5 1 31 99 70 0...

Страница 43: ...03 78 13 642 0 179 1 56 87 1 49 101 70 0 070 5 11 0 03 79 13 823 0 181 1 55 87 2 1 35 102 69 0 060 4 63 0 04 80 14 001 0 178 1 54 87 4 1 43 102 70 0 070 6 72 0 04 81 14 181 0 180 1 55 87 5 1 42 103 7...

Страница 44: ...111 19 575 0 179 1 52 91 2 1 35 99 70 0 070 6 32 0 06 112 19 756 0 181 1 52 91 4 1 56 101 70 0 070 4 85 0 03 113 19 935 0 179 1 53 91 4 1 46 100 71 0 070 6 22 0 04 114 20 114 0 179 1 53 91 5 1 54 102...

Страница 45: ...25 511 0 179 1 54 93 4 1 35 100 70 0 080 6 96 0 05 145 25 690 0 179 1 53 93 5 1 6 102 71 0 070 4 61 0 03 146 25 871 0 181 1 54 93 5 1 51 101 69 0 070 5 98 0 04 147 26 050 0 179 1 55 93 6 1 45 101 70...

Страница 46: ...03 177 31 436 0 179 1 56 94 6 1 47 100 70 0 070 7 27 0 05 178 31 615 0 179 1 53 94 6 1 56 98 70 0 070 4 93 0 03 179 31 796 0 181 1 53 94 6 1 54 102 69 0 070 5 01 0 03 180 31 974 0 178 1 51 94 6 1 39 9...

Страница 47: ...210 37 357 0 179 1 55 94 6 1 54 98 70 0 060 3 48 0 01 211 37 538 0 181 1 52 94 6 1 51 99 70 0 050 3 66 0 01 212 37 716 0 178 1 53 94 6 1 43 97 70 0 050 3 70 0 03 213 37 896 0 180 1 53 94 7 1 54 100 70...

Страница 48: ...02 243 43 269 0 178 1 52 94 3 1 59 100 70 0 050 4 48 0 03 244 43 448 0 179 1 51 94 3 1 37 99 68 0 060 3 90 0 02 245 43 627 0 179 1 52 94 3 1 41 99 69 0 050 3 27 0 03 246 43 805 0 178 1 54 94 4 1 39 9...

Страница 49: ...02 276 49 162 0 180 1 51 94 2 1 38 100 70 0 050 4 70 0 04 277 49 339 0 177 1 50 94 1 1 59 98 69 0 050 2 95 0 03 278 49 517 0 178 1 49 94 2 1 62 97 69 0 050 3 50 0 02 279 49 696 0 179 1 52 94 1 1 43 9...

Страница 50: ...55 034 0 177 1 49 94 1 57 98 69 0 060 3 88 0 02 310 55 211 0 177 1 52 94 1 4 100 69 0 050 3 11 0 02 311 55 390 0 179 1 50 94 1 1 39 99 69 0 050 3 67 0 03 312 55 566 0 176 1 48 94 1 1 58 98 69 0 060 3...

Страница 51: ...94 3 1 44 100 69 0 060 3 48 0 01 342 60 885 0 175 1 50 94 3 1 5 99 69 0 060 3 94 0 03 343 61 064 0 179 1 50 94 3 1 4 99 70 0 050 3 70 0 02 344 61 239 0 175 1 49 94 3 1 59 99 69 0 050 3 82 0 02 345 61...

Страница 52: ...5 1 3615 1 3615 2 0 1 Filters A 1st Hour 247 6 2 21 11 18 247 7 2 22 9 20 B 251 6 2 21 11 18 251 4 2 22 9 20 C Post 1st Hour 249 6 2 21 11 18 249 6 2 22 9 20 Amb 124 1 2 21 11 18 124 1 2 22 9 20 Probe...

Страница 53: ...Start Time 8 35 Time Notes N A N A Test Notes Test Burn Start Time 9 35 Time Notes 0 min 60 min 180 min 360 min Started sampling at high fire setting Changed out 1st hr filter train switched to the m...

Страница 54: ......

Страница 55: ......

Страница 56: ......

Страница 57: ...TM D5373 wt 8 59 8 23 Nitrogen ASTM D5373 wt 0 20 0 20 Oxygen ASTM D3176 wt 43 98 42 13 Note As received values do not include hydrogen and oxygen in the total moisture Chlorine ASTM D6721 mg kg Fluor...

Страница 58: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...

Страница 59: ...basis kg BR Average dry burn rate over full integrated test run kg hr BRSi Average dry burn rate over test run segment i kg hr Vs Average gas velocity in the dilution tunnel ft sec PR Proportional Ra...

Страница 60: ...moisture of test fuel dry basis MSwb weight of test fuel in hopper at start of test run wet basis kg MEwb weight of test fuel in hopper at end of test run wet basis kg Sample Calculation FM 4 37 MSwb...

Страница 61: ...t of test fuel in hopper at start of test run segment i wet basis kg MESiwb weight of test fuel in hopper at end of test run segment i wet basis kg Sample Calculation from medium burn rate segment FM...

Страница 62: ...y burn rate over full integrated test run kg hr ASTM E2779 equation 3 60 MBdb Where Total length of full integrated test run min Sample Calculation MBdb 8 32 kg 360 min 60 x 8 32 BR 1 39 kg hr 360 BR...

Страница 63: ...er test run segment i kg hr ASTM E2779 equation 4 60 MBSidb Si Where Si Total length of test run segment i min Sample Calculation from medium burn rate segment MBSidb 3 15 kg 120 min 60 x 3 15 BR 1 58...

Страница 64: ...Hg Pg Static pressure of tunnel in H20 in Hg in H20 13 6 Ms The dilution tunnel wet molecular weight Ms 28 78 assuming a dry weight of 29 lb lb mole Sample calculation 8 93 11 38 83 4 1 2 Vs 0 785 x 8...

Страница 65: ...ectional area of dilution tunnel ft2 Tstd Standard absolute temperature 528 R Ps Absolute average gas static pressure in dilution tunnel Pbar Pg in Hg Ts Absolute average gas temperature in the diluti...

Страница 66: ...e pressure differential across the orifice meter in H2O Tm Absolute average dry gas meter temperature R Sample Calculation Using equation for Train A 1 49 Vm std 17 64 x 68 125 x 0 994 x 13 6 62 8 460...

Страница 67: ...iculate matter from filters mg mg mass of particulate matter from filter seals mg Sample Calculation Using equation for Train A first hour mn 0 1 1 1 0 1 mn 1 3 mg Using equation for Train A remainder...

Страница 68: ...mn Total mass of particulate matter collected in the sampling train mg Vm std Volume of gas sampled corrected to dry standard conditions dscf Sample calculation For Train A 4 0 69 87 Cs 0 00006 g dsc...

Страница 69: ...gas flow rate dscf hr Total time of test run minutes Sample calculation For Train A ET 0 000057 0 000002 x 25194 6 x 360 60 ET 8 39 g For Train B ET 0 000065 0 000002 x 25194 6 x 360 60 ET 9 58 g Aver...

Страница 70: ...verage gas velocity in the dilution tunnel ft sec Tmi Absolute average dry gas meter temperature during the ith time interval o R Tm Absolute average dry gas meter temperature o R Tsi Absolute average...

Страница 71: ...ntegrated test run g hr ASTM E2779 equation 5 PMR 60 ET Where ET Total particulate emissions grams Total length of full integrated test run min Sample Calculation ET Dual train average 8 99 g 360 min...

Страница 72: ...un g dry kg of fuel burned ASTM E2779 equation 6 PMF ET MBdb Where ET Total particulate emissions grams MBdb Weight of test fuel burned during test run dry basis kg Sample Calculation ET Dual train av...

Страница 73: ...99 9 78 5 78 4 14 3 7 89 9 14 7 56 9 14 21 7 86 0 03 6 74 168 1 19 90 13 14 157 1 19 6 100 3 76 6 76 8 16 9 7 86 9 56 7 53 9 56 22 7 83 0 04 7 23 149 6 19 82 12 57 157 4 19 5 100 1 77 4 77 5 15 7 7 8...

Страница 74: ...83 5 70 0 03 5 80 211 4 20 04 14 23 135 1 20 8 100 4 77 3 77 6 19 6 5 70 34 36 5 55 33 33 84 5 68 0 03 5 73 215 1 20 05 14 31 134 8 20 8 100 4 77 2 77 5 19 8 5 68 34 67 5 52 33 64 85 5 65 0 03 6 08 19...

Страница 75: ...74 55 04 153 3 79 0 03 5 11 252 7 20 15 15 02 131 6 21 1 100 4 76 3 76 6 22 2 3 79 56 34 3 72 55 36 154 3 77 0 02 5 76 213 8 20 05 14 28 132 0 21 1 100 5 77 6 78 0 19 8 3 77 56 61 3 69 55 62 155 3 73...

Страница 76: ...33 73 16 2 29 72 44 223 2 32 0 01 3 16 472 9 20 45 17 29 97 4 19 4 101 5 74 9 76 1 36 1 2 32 73 32 2 28 72 60 224 2 29 0 01 3 10 483 6 20 46 17 36 97 7 19 4 101 5 74 6 75 8 36 8 2 29 73 63 2 25 72 92...

Страница 77: ...14 86 35 293 1 13 0 02 4 31 319 0 20 27 15 95 97 5 19 6 100 8 78 7 79 3 26 4 1 13 86 95 1 12 86 56 294 1 12 0 02 3 16 470 9 20 45 17 28 96 9 19 6 101 2 75 1 76 0 35 9 1 12 87 10 1 11 86 72 295 1 12 0...

Страница 78: ...28 96 61 344 0 27 0 02 3 82 372 6 20 35 16 52 99 0 19 8 101 0 77 2 77 9 29 7 0 27 96 87 0 27 96 77 345 0 25 0 02 3 03 494 7 20 47 17 43 99 6 19 7 101 3 74 0 75 0 37 4 0 25 97 08 0 25 96 98 346 0 24 0...

Страница 79: ...9 37 598 3 88 8 59 2 77 19639 20 4 19 80 09 21 24 1 74 7 51 0 02 0 17 38 94 75 96 0 17 0 11 462 88 43 42 2 43 430 26 598 3 88 8 59 2 77 19639 20 4 19 80 16 21 26 1 87 8 06 0 02 0 19 38 88 67 61 0 22 0...

Страница 80: ...77 19639 20 4 19 79 94 21 21 1 50 6 47 0 02 0 15 38 95 95 60 0 20 0 14 537 08 43 48 2 43 408 26 466 3 88 8 59 2 77 19639 20 4 19 79 93 21 20 1 48 6 39 0 02 0 15 38 95 97 32 0 20 0 14 543 58 43 49 2 4...

Страница 81: ...2 77 19639 20 4 19 79 84 21 18 1 32 5 72 0 02 0 13 38 95 114 38 0 23 0 17 608 06 43 54 2 43 404 71 561 3 88 8 59 2 77 19639 20 4 19 79 94 21 20 1 48 6 42 0 02 0 15 39 02 96 72 0 14 0 15 541 52 43 51...

Страница 82: ...2 77 19639 20 4 19 79 54 21 10 0 81 3 53 0 03 0 08 39 25 214 98 0 12 0 37 989 05 43 94 2 43 370 59 436 3 88 8 59 2 77 19639 20 4 19 79 53 21 10 0 79 3 47 0 03 0 08 39 26 219 89 0 13 0 38 1007 61 43 9...

Страница 83: ...2 77 19639 20 4 19 79 72 21 15 1 11 4 82 0 03 0 11 39 06 144 57 0 18 0 23 722 44 43 67 2 43 370 65 175 3 88 8 59 2 77 19639 20 4 19 79 54 21 10 0 81 3 54 0 03 0 08 39 11 214 02 0 25 0 35 985 03 43 90...

Страница 84: ...2 77 19639 20 4 19 79 64 21 13 0 98 4 28 0 03 0 10 39 08 169 03 0 20 0 28 814 91 43 75 2 43 372 15 352 3 88 8 59 2 77 19639 20 4 19 79 52 21 09 0 78 3 40 0 03 0 08 39 12 224 93 0 26 0 37 1026 26 43 9...

Страница 85: ...83 3948 16 5293 10 4775 99 292 82 213 13 281 85 46 73 1717 83 88 38 2115 22 118 43 4404 82 134 04 5477 60 4111 16 3995 07 3951 36 5297 40 4779 87 292 76 212 96 275 84 61 46 1695 87 78 26 2114 29 118 4...

Страница 86: ...1 54 4357 85 3983 77 293 98 176 79 327 11 57 71 1767 82 126 77 2084 97 116 51 4404 14 113 94 4525 61 3411 57 3318 90 3281 82 4344 08 3972 04 293 98 176 26 332 00 58 41 1783 92 129 22 2084 72 116 48 44...

Страница 87: ...17 64 3181 59 4203 48 3851 02 294 21 170 75 378 24 65 39 1934 58 153 53 2082 06 116 18 4593 69 111 00 4402 35 3320 47 3230 72 3194 53 4221 76 3866 65 294 21 171 80 321 15 38 78 1729 91 138 40 2081 12...

Страница 88: ...48 2237 19 2889 14 2710 43 292 59 119 89 499 14 35 47 2212 70 333 39 2051 23 113 41 4698 45 93 84 3063 14 2328 47 2269 97 2243 61 2897 86 2718 20 292 59 120 26 512 01 36 14 2260 69 341 07 2052 37 113...

Страница 89: ...260 30 2234 05 2885 51 2706 62 292 76 119 13 335 19 51 70 1613 97 209 71 2038 13 113 40 4061 81 63 47 3029 82 2303 45 2245 66 2219 57 2865 66 2689 11 292 71 118 49 492 99 70 65 2186 34 313 52 2048 21...

Страница 90: ...9 36 2272 71 2938 60 2753 33 292 93 121 30 398 71 58 38 1852 06 246 29 2044 00 113 52 4341 68 68 09 3128 74 2377 21 2317 21 2290 36 2962 39 2774 68 292 87 122 39 534 70 73 64 2350 50 329 85 2053 68 11...

Страница 91: ...2 195 94 660 2 0 20 0 07 1 183 80 669 1 0 30 0 05 1 140 02 459 1 0 15 0 05 1 135 27 463 1 0 18 0 04 1 135 31 464 1 0 14 0 05 1 192 05 662 1 0 26 0 06 2 189 23 666 2 0 19 0 06 1 134 29 465 1 0 14 0 05...

Страница 92: ...401 1 0 17 0 04 1 19 126 23 425 1 0 21 0 06 1 63 120 85 431 2 0 15 0 06 1 79 115 73 394 2 0 15 0 06 1 68 106 59 361 2 0 14 0 05 1 62 112 93 397 1 0 14 0 05 0 10 119 84 431 0 0 24 0 05 0 34 117 25 392...

Страница 93: ...35 409 0 0 21 0 04 1 56 105 08 371 2 0 13 0 05 2 17 114 05 363 2 0 16 0 07 2 13 113 13 364 2 0 15 0 07 2 84 126 26 438 2 0 11 0 07 0 14 121 56 440 0 0 25 0 05 1 09 133 20 472 1 0 22 0 06 1 45 141 13...

Страница 94: ...86 239 2 0 08 0 06 2 94 72 22 192 4 0 16 0 08 2 11 50 50 169 2 0 06 0 05 5 93 99 77 298 4 0 07 0 12 6 75 112 25 330 8 0 08 0 14 1 62 45 71 174 3 0 05 0 04 2 50 43 03 134 1 0 03 0 05 1 23 78 98 315 1...

Страница 95: ...81 271 3 0 11 0 09 2 81 89 42 308 3 0 17 0 08 4 20 96 99 258 4 0 22 0 12 2 46 65 94 243 3 0 08 0 06 2 16 44 28 133 3 0 06 0 05 3 39 67 30 199 1 0 10 0 08 4 02 97 37 345 4 0 12 0 09 1 01 70 06 282 1 0...

Страница 96: ...54 169 1 0 04 0 06 3 05 99 57 343 2 0 19 0 09 3 95 93 26 307 5 0 12 0 09 2 94 71 03 240 3 0 09 0 07 4 58 92 74 264 5 0 13 0 11 3 07 72 60 238 4 0 09 0 07 1 81 59 54 206 2 0 11 0 05 5 02 101 85 299 3...

Страница 97: ...od for Determining Particulate Matter Emissions from Pellet Heaters ASTM E2779 10 for a pellet fuel appliance This request seeks an alternative to section 9 4 1 2 of ASTM E2779 10 which specifies test...

Страница 98: ...0 of the span between the high and low burn rates Additionally this approval is based on the understanding that the lowest heat output Btu hr setting available to the user and corresponds to the lowes...

Страница 99: ...me this alternative will be reconsidered and possibly withdrawn If you have additional questions regarding this approval please contact Angelina Brashear of my staff at 919 541 4746 or brashear angeli...

Страница 100: ...test reports the Measurement Technology Group has uncovered an error in determining the appropriate Medium Burn Rate Category when using ASTM E 2779 for compliance pursuant to 40 CFR 60 subpart AAA Sp...

Страница 101: ...ible compliance requirement Applying the equation laid out above the value of 1 51 is derived and therefore presents an appropriate and likely attainable emissions test requirement for the Medium Burn...

Страница 102: ......

Страница 103: ......

Страница 104: ......

Страница 105: ...lding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or u...

Страница 106: ...et fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Method 28R a...

Страница 107: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 108: ...ires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed...

Страница 109: ...SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL C...

Страница 110: ...e of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm thick is recommended for this installation D B C B A A Rear through wall 1 25 mm B Side 6 152 mm C Front 6 152 m...

Страница 111: ...rate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certif...

Страница 112: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 113: ...nd void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the hous...

Страница 114: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 115: ...system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6...

Страница 116: ...ypically very blue at the bottom and resembles a blow torch If this situation continues the fuel in the burn pot will be consumed and the fire will go out Matching the amount of air required for prope...

Страница 117: ...d by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the arrows again to adjust fan speed When the heater is in the manual mode the...

Страница 118: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 119: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 120: ...tove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 Adju...

Страница 121: ...rswitch shuttingthefuelfeedoff Thestove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean...

Страница 122: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 123: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 124: ...d or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearof...

Страница 125: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 126: ...ass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869...

Страница 127: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 128: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 129: ...2022 United States Stove Company 25 NOTES...

Страница 130: ...de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s r...

Страница 131: ...1 4 69762 Assemblage Burnpot 1 5 80780 Ir distance 1 6 80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 8086...

Страница 132: ...nt deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chale...

Страница 133: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 134: ...rait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gan...

Страница 135: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 136: ...int et la mention E2 s affiche sur l cran deux chiffres Le po le doit s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le...

Страница 137: ...le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t...

Страница 138: ...inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit...

Страница 139: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 140: ...de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuy...

Страница 141: ...ant une dur e suffisante le pot de combustion se remplira avec trop de combustible et le feu s touffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 142: ...ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette installation AVERT...

Страница 143: ...chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est...

Страница 144: ...re garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans une zone o il ne g ne pas la charpente de la maison l...

Страница 145: ...riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d bit d chappement et les performances du po le Chaque coude ou t r duit le potenti...

Страница 146: ...aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendant le d placement de la maison mobile Apr...

Страница 147: ...s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de chemin e pour une i...

Страница 148: ...DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 149: ...de c bles comme illustr tape 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est x tape 3 Connecter les install s en usine faisceaux de c blage sur l...

Страница 150: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 151: ...let peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Tem...

Страница 152: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...

Страница 153: ...lding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or u...

Страница 154: ...et fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Method 28R a...

Страница 155: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 156: ...OR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF...

Страница 157: ...mm in front 6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector o...

Страница 158: ...otective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire...

Страница 159: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 160: ...d void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house...

Страница 161: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 162: ...d and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition int...

Страница 163: ...blue at the bottom and resembles a blow torch If this situation continues the fuel in the burn pot will be consumed and the fire will go out Matching the amount of air required for proper combustion...

Страница 164: ...the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the arrows again to adjust fan speed When the heater is in the manual mode the optional therm...

Страница 165: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 166: ...educed performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could res...

Страница 167: ...stove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 Adj...

Страница 168: ...atetheairswitch shuttingthefuelfeedoff Thestove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove an...

Страница 169: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 170: ...loves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight...

Страница 171: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 172: ...d or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearof...

Страница 173: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 174: ...ass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869...

Страница 175: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 176: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 177: ...2022 United States Stove Company 25 NOTES...

Страница 178: ...de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s r...

Страница 179: ...1 4 69762 Assemblage Burnpot 1 5 80780 Ir distance 1 6 80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 8086...

Страница 180: ...nt deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chale...

Страница 181: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 182: ...rait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gan...

Страница 183: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 184: ...int et la mention E2 s affiche sur l cran deux chiffres Le po le doit s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le...

Страница 185: ...le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t...

Страница 186: ...inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit...

Страница 187: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 188: ...de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuy...

Страница 189: ...ant une dur e suffisante le pot de combustion se remplira avec trop de combustible et le feu s touffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 190: ...ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette installation AVERT...

Страница 191: ...chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est...

Страница 192: ...re garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans une zone o il ne g ne pas la charpente de la maison l...

Страница 193: ...riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d bit d chappement et les performances du po le Chaque coude ou t r duit le potenti...

Страница 194: ...aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendant le d placement de la maison mobile Apr...

Страница 195: ...s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de chemin e pour une i...

Страница 196: ...DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 197: ...de c bles comme illustr tape 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est x tape 3 Connecter les install s en usine faisceaux de c blage sur l...

Страница 198: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 199: ...let peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Tem...

Страница 200: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...

Страница 201: ...ials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room he...

Страница 202: ...od pellet fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Metho...

Страница 203: ...Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as pe...

Страница 204: ...ROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FR...

Страница 205: ...n front 6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 2...

Страница 206: ...both a hearth pad if used and the floor of the home The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star washer to penetrate...

Страница 207: ...f the installation is over 2 500 feet above sea level We recommend the use of Simpson Dura Vent or Metal Fab pipe if you use other pipes consult your local building codes and or building inspectors Do...

Страница 208: ...BTAIN COMBUSTION AIR FROM THE ATTIC GARAGE OR ANY OTHER UNVENTILATED AREA YOU MAY OBTAIN COMBUSTION AIR FROM A VENTILATED CRAWL SPACE DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS...

Страница 209: ...outside wall and a clean out tee should be placed on the pipe with a 90 degree turn away from the house At this point a 3ft 0 91m minimum section of pipe should be added with a horizontal cap which w...

Страница 210: ...system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 t...

Страница 211: ...flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a blow torch If this situation continues the fuel in the burn pot will be consume...

Страница 212: ...rdance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Страница 213: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 214: ...by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust have been or are wet will result in reduced performance Store your pellets in a dry plac...

Страница 215: ...s to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater OPTIMAL OPERATION This pellet stove has been certified by the US EPA to meet strict...

Страница 216: ...ainst federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual SHUTDOWN PROCEDURE WARNING NEVERSHUTDOWNTHISUN...

Страница 217: ...y Overtimeashordustmayaccumulateontheblades of the circulation exhaust fans The fans should be inspected periodically and if any accumulation is present vacuumed clean as the ash or dust can impede th...

Страница 218: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 219: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 220: ...r gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of...

Страница 221: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 222: ...ass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869...

Страница 223: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 224: ...Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No _______________...

Страница 225: ...___________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie _______________________...

Страница 226: ...de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s r...

Страница 227: ...1 4 69762 Assemblage Burnpot 1 5 80780 Ir distance 1 6 80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 8086...

Страница 228: ...deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur...

Страница 229: ...t me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automati...

Страница 230: ...ait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gant...

Страница 231: ...cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant c...

Страница 232: ...t et la mention E2 s a che sur l cran deux chi res Le po le doit s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le pot d...

Страница 233: ...le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t a...

Страница 234: ...nf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit se...

Страница 235: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 236: ...de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuy l...

Страница 237: ...endant une dur e su sante le pot de combustion se remplira avec trop de combustible et le feu s tou era Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 238: ...ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette installation AVERT...

Страница 239: ...chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chau e eau est...

Страница 240: ...e garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans une zone o il ne g ne pas la charpente de la maison le...

Страница 241: ...p riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d bit d chappement et les performances du po le Chaque coude ou t r duit le potent...

Страница 242: ...aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendant le d placement de la maison mobile Apr...

Страница 243: ...s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de chemin e pour une i...

Страница 244: ...DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 245: ...de c bles comme illustr tape 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est x tape 3 Connecter les install s en usine faisceaux de c blage sur l...

Страница 246: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 247: ...let peut e ectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Temp...

Страница 248: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...

Страница 249: ...fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Страница 250: ...od pellet fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Metho...

Страница 251: ...________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Instal...

Страница 252: ...RGE PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH...

Страница 253: ...n front 6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 2...

Страница 254: ...grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certified ceiling fire stop and rain cap When mo...

Страница 255: ...purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system 90 degree elbows accum...

Страница 256: ...HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house framing wiring etc 2...

Страница 257: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 258: ...d and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition int...

Страница 259: ...nd resembles a blow torch If this situation continues the fuel in the burn pot will be consumed and the fire will go out Matching the amount of air required for proper combustion to the fuel rate is t...

Страница 260: ...r down Draft Fan when pressed the display will show Df A which is automatic Press the arrows again to adjust fan speed When the heater is in the manual mode the optional thermostat will not properly c...

Страница 261: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 262: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 263: ...ff before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 Adjust the feed rate to the desired setting by p...

Страница 264: ...will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean the burn pot and the area inside the bu...

Страница 265: ...service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove...

Страница 266: ...aking sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperature silicone to adhere the gasket to the door 6 Never use su...

Страница 267: ...or gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of...

Страница 268: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 269: ...ass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869...

Страница 270: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 271: ...__ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _________________________...

Страница 272: ...24 2022 United States Stove Company NOTES...

Страница 273: ...___________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie _______________________...

Страница 274: ...de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s r...

Страница 275: ...1 4 69762 Assemblage Burnpot 1 5 80780 Ir distance 1 6 80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 8086...

Страница 276: ...t deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleu...

Страница 277: ...t me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automati...

Страница 278: ...ait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gant...

Страница 279: ...cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant c...

Страница 280: ...t s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le pot de combustion et la zone l int rieur du bo tier du pot de combus...

Страница 281: ...r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t attendez quelques minutes d gagez le pot de combustion et recomm...

Страница 282: ...nf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit se...

Страница 283: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 284: ...de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuy l...

Страница 285: ...endant une dur e su sante le pot de combustion se remplira avec trop de combustible et le feu s tou era Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 286: ...s ci dessous ne sont que des exemples Veuillez con rmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur quali de proc der cette installation AVERTIS...

Страница 287: ...les 4 pieds 1 22 m pour rendre le syst me plus stable Si vous habitez dans une r gion qui a fortes chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir...

Страница 288: ...tilisation d autres composants autres que mentionn s ici pourrait causer des l sions corporelles les dommages de chau age et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez vo...

Страница 289: ...pour permettre la collecte des cendres volantes et pour permettre le nettoyage p riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d...

Страница 290: ...la maison mobile et doit tre install l aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendan...

Страница 291: ...s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de chemin e pour une i...

Страница 292: ...DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 293: ...de c bles comme illustr tape 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est x tape 3 Connecter les install s en usine faisceaux de c blage sur l...

Страница 294: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 295: ...let peut e ectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Temp...

Страница 296: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...

Страница 297: ...of components not supplied with appliance or any other components not expressly authorized and approved by USSC 8 modification of the appliance not expressly authorized and approved by USSC in writing...

Страница 298: ...utoris es et approuv es par crit par USSC et ou 9 les interruptions ou fluctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis s...

Страница 299: ...of components not supplied with appliance or any other components not expressly authorized and approved by USSC 8 modification of the appliance not expressly authorized and approved by USSC in writin...

Страница 300: ...autoris es et approuv es par crit par USSC et ou 9 les interruptions ou fluctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis...

Страница 301: ...8 432 5 988 5 477 8 510 6 105 5 596 0 998 0 993 0 992 Factor Deviation From Average 0 998 0 993 0 992 Calculations 1 Deviation Average value for all runs current run value 2 Vstd x Std x Pbar Pstd 13...

Страница 302: ...ing inH2O Difference Reference UUT Error of Full Range 0 0 0 6 0 54 0 54 0 0 0 0 6 1 2 0 90 0 91 0 01 0 3 1 2 1 8 1 56 1 57 0 01 0 3 1 8 2 4 1 94 1 97 0 03 1 0 2 4 3 0 2 68 2 72 0 04 1 3 Acceptable to...

Страница 303: ...eading inH2O Difference Reference UUT Error of Full Range 0 0 0 2 0 17 0 17 0 0 0 0 2 0 4 0 36 0 36 0 0 0 0 4 0 6 0 51 0 51 0 0 0 0 6 0 8 0 63 0 63 0 0 0 0 8 1 0 0 98 0 98 0 0 0 Acceptable tolerance i...

Страница 304: ...8 5 302 7 473 5 095 5 298 7 439 1 004 1 001 1 001 Factor Deviation From Average 1 004 1 001 1 001 Calculations 1 Deviation Average value for all runs current run value 2 Vstd x Std x Pbar Pstd 13 6 x...

Страница 305: ...eading inH2O Difference Reference UUT Error of Full Range 0 0 0 6 0 53 0 53 0 0 0 0 6 1 2 1 06 1 06 0 0 0 1 2 1 8 1 43 1 43 0 0 0 1 8 2 4 1 95 1 97 0 02 0 7 2 4 3 0 2 64 2 67 0 03 1 0 Acceptable toler...

Страница 306: ...fference Reference UUT Error of Full Range 0 0 0 2 0 178 0 180 0 002 0 2 0 2 0 4 0 371 0 386 0 015 1 5 0 4 0 6 0 558 0 562 0 004 0 4 0 6 0 8 0 675 0 680 0 005 0 5 0 8 1 0 0 922 0 917 0 005 0 5 Accepta...

Страница 307: ...8 133 7 482 5 384 8 132 7 488 0 997 0 997 0 996 Factor Deviation From Average 0 997 0 997 0 996 Calculations 1 Deviation Average value for all runs current run value 2 Vstd x Std x Pbar Pstd 13 6 x TD...

Страница 308: ......

Страница 309: ......

Страница 310: ...Barometer mbar 6 2E 01 1013 0 1005 8 1005 1021 mbar Remarks Many factors may cause the unit to drift out of calibration before the recommended due date Any reported error is the absolute value between...

Страница 311: ......

Страница 312: ......

Страница 313: ...and Technology Three point mounting dual leveling adjustment and circular level vial assure rapid setup Durablock precision machined acrylic plastic gage body Sensitive 0 50 microamp D C meter acts a...

Страница 314: ...a free run ning multivibrator operating at a frequency of approximately two kilohertz Completion of the A C circuit activates a bridge rectifier which provides the signal for indication on a sensitive...

Страница 315: ...he point out of the fluid by turning the micrometer barrel counter clockwise to a reading of 010 or more Again watch the meter and this time lower the point by turning the micrometer barrel The point...

Страница 316: ...n continues to be sluggish replace the size AA 1 5 volt battery Replace the battery at least once a year to avoid deterioration of battery and damage to gage Leakproof alkaline battery is recom mended...

Страница 317: ...E 01 Raw Data 4535 92370000 4536 1022299 0 1785299 0 0000000 0 0000000 g Remarks Many factors may cause the unit to drift out of calibration before the recommended due date Any reported error is the a...

Страница 318: ......

Страница 319: ......

Страница 320: ...inal Asset No N A Range Max Capacity Readability d 1 1000 lb 0 02 lb Procedure Calibration Guideline ASTM E898 20 METTLER TOLEDO Work Instruction 30260953 This calibration certificate including proced...

Страница 321: ...N A 500 02 lb 6 N A 500 02 lb N A 0 010 lb Standard Deviation The results of this graph are based upon the absolute values of the differences from the mean value As Left The d in the graph represents...

Страница 322: ...500 00 lb 0 00 lb 0 10 lb 2 4 750 lb 750 00 lb 0 00 lb 0 15 lb 2 5 1000 lb 1000 00 lb 0 00 lb 0 17 lb 2 05 6 750 lb 750 00 lb 0 00 lb 0 15 lb 2 7 500 lb 500 00 lb 0 00 lb 0 10 lb 2 8 250 lb 250 00 lb...

Страница 323: ...ds The weights were calibrated and certified by an accredited calibration laboratory Weight Set 1 NIST NIST F Weight Set No 182 50 s 25 s Date of Issue 25 Jun 2019 Certificate Number OR 19 186 F Calib...

Страница 324: ...for the evaluation of the measurement uncertainty in use 10 0 10 6 K Temperature range on site for the evaluation of the measurement uncertainty in use 10 K Linearization of Uncertainty Equation Rang...

Страница 325: ...4 Test Load From To Tolerance 0 00 lb 0 00 lb 0 005 lb 0 02 lb 10 00 lb 0 01 lb 10 02 lb 40 00 lb 0 02 lb 40 02 lb 80 00 lb 0 03 lb 80 02 lb 1000 00 lb 0 05 lb As Found As Left Tolerance Eccentricity...

Страница 326: ...ort is complete and accurate The instrumentation used for the test was properly calibrated The representative model tested meets the applicable emission limits The tests have been conducted per the ap...

Страница 327: ...Council of Canada to ISO 17065 2012 Requirements For Bodies Operating Product Certification Systems Revision History Date March 29 2022 Original Issue Date May 17 2022 The following to the report wer...

Страница 328: ...document may be revised periodically without public notice If you have additional questions please contact Rafael Sanchez at 202 564 7028 or via email at sanchez rafael epa gov Contents Application f...

Страница 329: ...Yes No Model Name and Design Number The model name and design number must clearly distinguish one model from another The name and design number cannot include the EPA symbol or logo or name or deriva...

Страница 330: ...boratory Supervisor Address 11785 Highway 212 Ste 305 City Clackamas State OR ZIP Code 97015 Phone 503 650 0088 Email Sebastian button pfsteco com Website www pfsteco com Remarks EPA Approved Third Pa...

Страница 331: ...and test results Documentation must include the items specified in the applicable test methods Documentation must include discussion of each test run and its appropriateness and validity and must inc...

Страница 332: ...thout written approval by the Administrator 13 Statement about Selling Wood Heaters without an EPA Certificate A statement acknowledging that it is unlawful to sell distribute or offer to sell or dist...

Страница 333: ...T 60 Subparts AAA AND QQQQ sections 60 537 and 60 5479 If you have additional questions please contact Rafael Sanchez at 202 564 7028 or via email at sanchez rafael epa gov Instructions The manufactur...

Страница 334: ...g requirements This document is not a substitute for those provisions or regulations nor is it a regulation itself In the event of a discrepancy please refer to 40 CFR PART 60 Subparts AAA AND QQQQ se...

Страница 335: ...claimer The statutory provisions and the EPA regulations described in this document contain legally binding requirements This document is not a substitute for those provisions or regulations nor is it...

Страница 336: ...ibed in this document contain legally binding requirements This document is not a substitute for those provisions or regulations nor is it a regulation itself In the event of a discrepancy please refe...

Страница 337: ...od for Determining Particulate Matter Emissions from Pellet Heaters ASTM E2779 10 for a pellet fuel appliance This request seeks an alternative to section 9 4 1 2 of ASTM E2779 10 which specifies test...

Страница 338: ...0 of the span between the high and low burn rates Additionally this approval is based on the understanding that the lowest heat output Btu hr setting available to the user and corresponds to the lowes...

Страница 339: ...me this alternative will be reconsidered and possibly withdrawn If you have additional questions regarding this approval please contact Angelina Brashear of my staff at 919 541 4746 or brashear angeli...

Страница 340: ...test reports the Measurement Technology Group has uncovered an error in determining the appropriate Medium Burn Rate Category when using ASTM E 2779 for compliance pursuant to 40 CFR 60 subpart AAA Sp...

Страница 341: ...ible compliance requirement Applying the equation laid out above the value of 1 51 is derived and therefore presents an appropriate and likely attainable emissions test requirement for the Medium Burn...

Страница 342: ...is captured A SUMMARY RESULTS PELLET HEATERS EPA Application Table Run Number Date Segments Run Time min Heat Output BTU hr 1st Hr Emissions g hr Integrated Total g hr CO Emissions g min Overall CO Em...

Отзывы: