MEMORANDUM
SUBJECT:
Appropriate calculation of Medium Burn Rate Category in ASTM E-2779 Testing
FROM:
Steffan Johnson
Group Leader
Measurement Technology Group
Air Quality Assessment Division
TO:
Robert Scinta, P.E.
Chief, Air Branch
Monitoring, Assistance, and Media Programs Division
Office of Compliance, Office of Enforcement and Compliance Assurance
During a recent review of pellet heater compliance test reports, the Measurement Technology
Group has uncovered an error in determining the appropriate Medium Burn Rate Category when
using ASTM E-2779 for compliance pursuant to 40 CFR 60, subpart AAA. Specifically, the
method requirements in section 9.4.1.2 and Table 1 of that test method incorrectly require that
the Medium Burn Rate Category must fall below 50% of the maximum burn rate. This is not
correct as this requirement assumes then that zero is the other bound for determining half of the
maximum.
02/02/2022
STEFFAN
JOHNSON
Digitally signed by
STEFFAN JOHNSON
Date: 2022.02.02
08:28:07 -05'00'
Содержание KP5522
Страница 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...
Страница 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...
Страница 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...
Страница 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 58: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 129: ...2022 United States Stove Company 25 NOTES...
Страница 177: ...2022 United States Stove Company 25 NOTES...
Страница 272: ...24 2022 United States Stove Company NOTES...
Страница 308: ......
Страница 309: ......
Страница 311: ......
Страница 312: ......
Страница 318: ......
Страница 319: ......