18
18
5. Input Wiring Connection (Optional Hardwire Connection)
1. Choose the appropriate conduit in accordance with all applicable, local, and electrical
safety codes and standards.
2. Using the appropriate tool, clamp the wire terminal to the copper wire. For non-insulated
terminals, use heat shrink tube to cover the non-insulated portion of the terminal.
3. Remove the front cover by removing the 4 screws at each corner of the charging station.
4. With the front cover placed to the side, use Philips screwdriver to release terminal screws
of the 6-50 or 14-50 Plug cable. Loosen the Strain Relief Fitting for plug and remove the
plug.
5. Remove the Strain Relief connector.
6. Insert the wire end passing through the conduit and insert them into the input wiring hole.
(Use Red wire for L1, Black wire for L2, Green wire for G). Attach the copper wire on the
corresponding terminal block. Use the following wire and torque force when connecting to
input terminal block.
Model
Terminal
Conductor
Rating
Torque
GRIZZL-E
Smart
90C,
copper wire
L1, L2, G
8 AWG
16 kgf-cm 13.88 lb-in
7. Once the input wiring and conduit are connected, reinstall the charging station font cover.