RP901 User Manual
Status:
Enable or Disable the Accepted Filter function. Pattern 1 must be defined if
Enable is selected while two patterns (Pattern 1 and Pattern 2) must be
defined if Enable-Range is selected.
Start Bit of EPC Code:
The start point (by 4 bits, from 0,4,8... to 248) of EPC Code to be compared.
Pattern 1 or Pattern 2:
the pattern string of Accepted Filter in hexadecimal. The length of Pattern 1
and Pattern 2 must be same and equal to the length of those numbers of EPC
code to be compared.
3.3.3 Rejected Filter
Rejected Filter defines a pattern or a range (2 patterns) of EPC Code. A Tag
can be Rejected if the selected part of its EPC Code is equal to Pattern 1 or
Pattern 1
≦
the selected part of its EPC code
≦
Pattern 2.
Configuration Method:
Enable or Disable Rejected Filter. Input the Start
Bit of EPC Code by 4 bits (0,4,8...) and the pattern
string of Rejected Filter in hexadecimal then click
to send the new parameter values to the
RP901.
Default Setting: Disable
Start Bit of EPC Code: 0
Pattern 1 :””
Pattern 2 :””
Status:
Enable or Disable the Rejected Filter function. Pattern 1 must be defined if
Enable is selected while two patterns (Pattern 1 and Pattern 2) must be
defined if Enable-Range is selected.
Start Bit of EPC Code:
The start point (by 4 bits, from 0,4,8... to 248) of EPC Code to be compared.
Pattern 1 or Pattern 2:
the pattern string of Rejected Filter in hexadecimal. The length of Pattern 1 and
Pattern 2 must be same and equal to the length of those numbers of EPC code
to be compared.
Note: The Accepted Filter will be processed first when both Accepted Filter and Rejected Filter
are enabled at the same time.