- 90 -
© 2018 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS652 User’s Manual
3.14.3 1D Quiet Zone Level
This feature sets the level of aggressiveness when decoding bar codes
with a reduced quiet zone (the margin on either side of a bar code), and
applies to symbologies enabled by a Reduced Quiet Zone parameter.
Because higher levels increase the decoding time and risk of misdecodes,
Zebra strongly recommends enabling only the symbologies which require
higher quiet zone levels, and leaving Reduced Quiet Zone disabled for all
other symbologies. Options are:
•
1D Quiet Zone Level 0
- The engine performs normally in terms of quiet
zone.
•
1D Quiet Zone Level 1
- The engine performs more aggressively in terms
of quiet zone.
•
1D Quiet Zone Level 2
- The engine only requires a quiet zone at the end
of bar code for decoding.
•
1D Quiet Zone Level 3
- The engine decodes anything in terms of quiet
zone or end of bar code.
1D Quiet Zone Level 0
1D Quiet Zone Level 1*
1D Quiet Zone Level 2
1D Quiet Zone Level 3