4.15 Timeout Between Decodes,
Same Symbol
Use this option in presentation mode or Continuous Bar Code Read mode
to prevent the engine from continuously decoding the same bar code
when it is left in the engine’s field of view. The bar code must be out of the
field of view for the timeout period before the engine reads the same
consecutive symbol. It is programmable in 0.1 second increments from
0.0 to 9.9 seconds. The default interval is 0.6 seconds. To select the
timeout between decodes for the same symbol, scan the following bar
code, and then scan two bar codes from
that correspond to the desired interval, in 0.1 second increments.
Timeout Between Decodes, Same Symbol