- 83 -
© 2018 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co., Ltd.
MS652 User’s Manual
3.13.5 GS1 DataBar Security Level
The engine offers four levels of decode security for GS1 DataBar (GS1
DataBar-14, GS1 DataBar Limited, GS1 DataBar Expanded) bar codes.
•
Security Level 0
- The engine operates in its most aggressive state, while
providing sufficient security decoding most in-spec
bar codes.
•
Security Level 1
- This setting eliminates most misdecodes while
maintaining reasonable aggressiveness.
•
Security Level 2
- Select this option with greater bar code security
requirements if Security Level 1 fails to eliminate
misdecodes
•
Security Level 3
- If you selected Security Level 2 and misdecodes still
occur, select this security level to apply the highest
safety requirements.
GS1 DataBar Security Level 0
GS1 DataBar Security Level 1*
GS1 DataBar Security Level 2
GS1 DataBar Security Level 3