Requirements

 

 

The UEC 6000 and the UEC 7000 units are for indoor use only. Keep the UEC 6000 and the  
UEC 7000 dry and avoid areas of high humidity. 

 

The UEC 7000 requires a higher current power supply (Unisys Direct P/N # 75-0497-901).  
The UEC 6000 can use its supplied power supply or the higher current power supply. See 

Specifications

Specifications

Specifications

Specifications

 on page 21 for power supply details. 

 

Do not remove any cabinetry other than the areas specified in this guide; removing cabinetry other 
than the areas specified in this guide will void the warranty. 

Recommendations

 

 

This unit may be installed and programmed by a distributor (reseller) other than the original 
manufacturer.  Record all distributor contact information for future reference. 

 

Save the original box and packing material. Re-use them if the unit must be shipped to a new location. 

 

Position the unit so that the operator has easy access to the check path and a clear view of the LED. 
Do not put the unit close to a heat source, in direct sunlight, or close to any device that can emit 
electromagnetic interference such as a computer monitor or power adapter. Do not use the unit near 
water, including a sink, swimming pool, or damp basement. 

Содержание UEC 6000 Series

Страница 1: ...UEC 6000 and UEC 7000 Series Installation Guide Unisys UEC 7011 Unisys...

Страница 2: ...d other countries The Unisys logo is a trademark of Unisys Corporation All other brand names and trademarks appearing in this guide are the property of their respective holders Copyright Unisys Corpor...

Страница 3: ...Contents Compliance Statements 2 Introduction 3 Requirements 4 Setting Up the UEC 6000 or UEC 7000 5 Maintaining the UEC 6000 or UEC 7000 16 Troubleshooting 18 Specifications 21 Warranty Information 2...

Страница 4: ...against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance...

Страница 5: ...Utilizing industry leading progressive MICR method and imaging technology the UEC 6000 and the UEC 7000 are ideal for Check Electronification Check Cashing and Walk in Bill Payment applications The in...

Страница 6: ...ther than the areas specified in this guide will void the warranty Recommendations This unit may be installed and programmed by a distributor reseller other than the original manufacturer Record all d...

Страница 7: ...ork connection depending on your unit and power connections B Unpack the Shipping Box 1 Open the top of the box 2 Remove and unwrap the items 3 Save the box and wrapping for future use NOTE Before unp...

Страница 8: ...B below does not include an MSR Scanner Model A will be graphically represented throughout this manual for consistency All other features of the UEC 6000 and UEC 7000 are available as standard or opti...

Страница 9: ...s Cover Latch Outside Cover in raised position Image Frame in raised position Image Sensor Document Feed Plate comes out to reveal the optional Franking Acknowledgement Printer Assembly UEC 7000 shown...

Страница 10: ...to a PC AUX Yellow Use this port to connect optional peripheral devices such as a pass through printer COM Green Use this port to connect to a PC or terminal TEL Purple This port offers an optional m...

Страница 11: ...ge into the unit I Access the Printer Assembly 1 Press the latch and lift the cover to access the imaging frame 2 Lift the imaging frame to access the feed plate 3 Locate the blue tab on the side of t...

Страница 12: ...nt feed plate by pressing down firmly until it clicks into place 4 Close the imaging frame 5 Close the outside cover CAUTION Avoid contact with the main drive roller to prevent ink transfer to documen...

Страница 13: ...one line into the telephone company wall jack Test the Telephone Line and Third Party Line 1 Call the third party line to ensure that it is working properly 2 If the third party line is not working co...

Страница 14: ...to power the LED will light up Your unit is now turned on CAUTION Disconnecting the power source while the terminal is processing a transaction may cause data files stored in the unit s memory to be...

Страница 15: ...it is ready to accept checks when the LED is green As shown on the right insert the check Flush to the right side of the UEC 6000 or the UEC 7000 Information side facing up MICR line to the inside rig...

Страница 16: ...ext job with a command from the terminal Amber Flashing The unit is sending or receiving information from the terminal wait Red Green Amber Flashing The unit is starting up or performing diagnostics w...

Страница 17: ...ful in reading the MICR line One long beep LED is flashing red An error occurred during processing or storing of the captured image A Typical Check Processing LED Cycle 1 The unit is on and idle the L...

Страница 18: ...s the latch and lift the cover to access the imaging frame 2 Lift the imaging frame to access the document feed plate 3 Locate the blue tab on the side of the unit With your thumb positioned on the ou...

Страница 19: ...locate and access the document sensors follow the instructions below 1 Press the latch and lift the cover to access the imaging frame 2 Lift imaging frame to access the document sensors 3 Use a lens c...

Страница 20: ...that they are still connected properly 2 Ensure the telephone line is working by removing the connection from the UEC 6000 or the UEC 7000 and connecting it to a telephone base unit 3 If the telephon...

Страница 21: ...rections below 1 Press the latch and lift the cover to access the imaging frame 2 Lift the imaging frame to access the document feed plate 3 Clear any paper or debris from the imaging frame and docume...

Страница 22: ...roperly Test the Card Swipe Mechanism 1 Ensure that you are swiping the card properly The black magnetic stripe on the back of the card must face downward and to the left 2 Try using another card to e...

Страница 23: ...x 6 2 wide x 5 3 high 22 5 cm long x 15 5 cm wide x 13 5 cm high Unit Weight UEC 6000 3 1lbs 1 4 Kg UEC 7000 3 4 lbs 1 5 Kg Unit Orientation For proper operation place unit on a level horizontal surfa...

Страница 24: ...W x 4 4 L 5 5 cm x 11 2 cm Maximum 4 W x 9 L 10 16 cm x 22 86 cm Weight Range 8 lb to 100 lb thermal paper to business card stock Font E13B MICR Character Set Alphanumeric OCR A and B font recognition...

Страница 25: ...V 34bis V 34 V F C V 32bis V 32 V 22bis V 22A B V 23 V 21 Bell 212A and 103 Error Correction V 42 LAPM and MNP 2 4 Data Compression V 42bis and MNP 5 Optional Magnetic Stripe Reader MSR Specifications...

Страница 26: ...below Equipment a may be newly manufactured b may be assembled from new or serviceable used parts that are equivalent to new parts in performance or c may have been previously installed During this tw...

Страница 27: ...ed to purchaser all of which is sold or licensed to purchaser AS IS Purchaser agrees to look solely to the warranties and remedies if any provided by the manufacturer or its Unisys reseller These limi...

Страница 28: ...tion 2006 Copyrighted material licensed by Unisys Corporation from a third party All rights reserved No part of this document may be reproduced in any form without the written consent of Unisys Corpor...

Отзывы: