10. DISASSEMBLY INSTRUCTION
PHOTOS
PROCEDURES
1. Before dismantling
1.1. Cut off the main power.
1.2. Administer 'Pump Down (refrigerant recovery)' so that not to
have refrigerant flown out during the course of dismantling.
2. Dismantle 'Door Front' from the main body.
2.1. Unfasten 3 screws from hinge to dismantle 'Door Front'.
2.2. Dismantle 'Door Front' by lifting it upwards.
* Caution: Take caution not to have 'Door Front' tip over while
unfastening screws or during storage after dismantling.
(1) DPA-246LR/LG