35
1
12
2)) R
Re
em
mo
otte
e c
co
on
nttrro
oll d
do
oe
es
s n
no
ott w
wo
orrk
k..
* Remote control trouble : Check signal diode, IC micom soldering and the troll battery.
* Main body trouble : Check the receive module and the connector connection.
Remote control OK?
IC7(MICOM) PIN 50
signal input?
Check the connector
connection?
YES
NO
Battery 2.5V
YES
NO
NO
NO
YES
MICOM trouble
Measure
YES
receive module trouble
Change the remote control