U G P - 3 0 E – C T 2
24
Troubleshooting Tips
Symptom
Possible Cause Solution
BURNERS
WILL
NOT
LIGHT.
Burner
parts
or
igniters
may
be
wet,
dirty
or
misaligned.
Check
that
the
burner
parts
are
clean,
dry
and
correctly
assembled.
Check
that
the
igniters
are
clean
and
dry.
TOP
BURNER
WILL
NOT
STAY
LIT
Failed
thermocouple
Replace
thermocouple
FLAMES
DO
NOT
BURN
ALL
AROUND
THE
BURNER
CAP.
Burner
parts
may
be
dirty
or
misaligned.
See
“Care
and
Cleaning”
instructions.
BURNER
FLAMES
ARE
VERY
LARGE
AND
YELLOW.
Burner
bezel
ports
are
clogged.
Burner
ports
or
burner
caps
are
not
positioned
properly.
Rangetop
is
being
operated
with
the
wrong
type
of
gas.
Regulator
is
not
installed,
is
faulty,
or
is
set
for
the
wrong
type
of
gas.
Clean
burner
bezel
ring
ports
with
straightened
paper
clip,
needle,
or
wire.
Remove
and
carefully
re
‐
install
burner
bezel
and
caps.
Ensure
that
the
type
of
rangetop
matches
the
gas
supply.
Check
installation,
replace
regulator,
or
set
regulator
for
proper
gas.
IGNITERS
ARE
SPARKING
BUT
BURNERS
ARE
NOT
IGNITING.
Gas
shut
‐
off
valve
is
in
the
“OFF”
position.
Turn
shut
‐
off
valve
to
the
“ON”
position.
Содержание UGP-30E CT2