![Unique Gas Products UGP-30E CT2 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/unique-gas-products/ugp-30e-ct2/ugp-30e-ct2_owners-manual_843654024.webp)
U G P - 3 0 E – C T 2
20
Gas Rangetop Conversion and Adjustment Guide
The rangetop is set for use with Natural Gas (NG). (The factory setting is indicated
on the serial plate. When set for Natural Gas (NG) Gas operation, the pressure
regulator will regulate the gas to 4” inches water column pressure. When set for
Liquefied Propane Gas (LPG) operation, the pressure regulator will regulate the
pressure to 11” inches water column
NG to LPG Conversion
Convertible Pressure Regulator
The rangetops are shipped to operate on Natural Gas (NG). Propane (LPG) orifices
are shipped with the unit in a separate envelope with the manual. Save the NG
orifices removed from the appliance for future use, make sure you note which
orifices are for which burner if you plan on converting back to NG.
The inlet pressure of the gas supply shall be in accordance with the nominal inlet
pressure of the regulator used on the rangetop or 1/2 psig maximum. The rangetop
should be tested by pressurizing the regulator with an inlet pressure at least 1 inch
water column above the manufacturer's specified manifold pressure shown on the
serial plate.
1.
Shut off gas leading to appliance.
2.
Unplug any electrical connections if you are using the 110V option, usually
located under the rangetop.
3.
Locate convertible regulator at the back of the rangetop, remove cap.
4.
Unscrew the plastic insert from the cap and turn it over so the shorter stem
is facing downwards for NG (Fig. A). Replace insert on the cap.
Cap located here – back right of rangetop
while facing it.
Содержание UGP-30E CT2
Страница 30: ...U G P 3 0 E C T 2 26 Wiring diagram UGP 30 CT2 ...
Страница 31: ...U G P 3 0 E C T 2 27 Parts Lists and Diagram ...