26
6
Hold Function
26
H
o
ld
Fun
ction
Chapter
6
6-1.
Hold function
The hold function operates during indicated value display or graph display.
Each hold operation is performed using the
key.
Hold mode (HOLD MODE)
There are six hold modes for the TM400.
When not using the hold function, be sure to turn OFF the hold mode and use the product.
(When turned OFF, the hold function does not operate and the input value is displayed at all times.)
<Setting range>
OFF, SAMPLE, PEAK, BOTTOM, P-P, AVERAGE, PEAK ANG
- OFF:
Hold function OFF
- Sample hold:
Holds an arbitrary point (torque, rotation speed, angle).
- Peak hold:
Holds the maximum value (peak value) of torque in the positive
direction.
Does not hold rotation speed or angle.
- Bottom hold:
Holds the maximum value (bottom value) of torque in the negative
direction.
Does not hold rotation speed or angle.
- Peak to peak hold:
The difference in the bottom and peak values of torque (range) is
displayed.
Does not hold rotation speed or angle.
- Average hold:
Holds the torque average in the specified section.
Does not hold rotation speed or angle.
- Peak hold (angle):
Holds the maximum value (peak value) of torque in the positive
direction and the maximum value (peak value) of angle in the positive
direction. Rotation speed will not be hold.
Start mode (START MODE)
There are two start mode settings for the TM400.
<Setting range>
KEY, LEVEL
- Key:
Monitors all data during the time period after the
key has been pressed
until the
key is pressed again.
- Level:
Monitors data after the indicated value has passed the start level until it passes the
stop level.
After the indicated value has passed the stop level, it waits until the value passes
the start level again.
* If the hold mode is set as sample hold setting, the start mode is ignored.
6
Hold Function
HOLD
HOLD
HOLD
Содержание TM400
Страница 1: ...01FEB2018REV 1 06 TM400 PORTABLE TORQUE MONITOR OPERATION MANUAL ...
Страница 61: ......