35
4
Calibration
35
Calibr
a
ti
on
Chapter
4
(6) Calibration setting is written to the TM201.
The values selected in (1) to (5) are written to the TM201.
■
Execution procedure
1.
Click the "Set" button.
2.
When the "Set" button is clicked, a
confirmation dialog to overwrite is
displayed, and click "Yes (Y)".
4-5.
Rotation stop settings for rotation speed
Minimum input rotation speed
Minimum input rotation speed that can be displayed is selectable.
≪
Setting value
≫
Example) When set at "2rpm"
Since waiting for pulse detection for the duration of maximum detection time is required when
rotation stops suddenly from high speed state, the previous rotation speed is not updated;
therefore, the display will become 0 rpm after the display of the rotation speed that was last
detected has held for 7.5 seconds.
Pulse rate
Minimum input rotation speed (frequency)
4 pulses
15 rpm
10 rpm
5 rpm
3 rpm
2 rpm
1 pulse
60 rpm
40 rpm
20 rpm
12 rpm
8 rpm
Max. detection time
1 sec
1.5 sec
3 sec
5 sec
7.5 sec
Rotation stops suddenly
Pulse
Display
3000rpm
0rpm
7.5sec (Display held)
2 rpm pulse does not arrive