EXPLANATION OF COMPARISON FUNCTIONS
44
EX
PLAN
ATION
OF C
O
MPAR
IS
ON FUN
C
TION
S
Chapter
6
6-1.
Calculation mode
Set the calculation method for the ch1 value and ch2 value.
0
:
ch1+ch2
The ch2 value is added to the ch1 value.
1
:
ch1-ch2
The ch2 value is subtracted from the ch1 value.
2
:
|ch1-ch2|
The absolute value of the difference between the ch1 value and
ch2 value is calculated.
3
:
High select
A larger value is always selected.
(When the ch1 value
≧
ch2 value, the ch 1 value results, and when
the ch1 value < ch2 value, the ch2 value results.)
4
:
Low select
A smaller value is always selected.
(When the ch1 value
≦
ch2 value, the ch 1 value results, and when
the ch1 value > ch2 value, the ch2 value results.)
■
Calculation mode setting method
1.
Select setting mode1.
Press
once.
2.
Set "Calculation mode."
Press
four
times
⇒
"Calculation mode" is
displayed.
Press
, and the highest digit blinks.
Input the setting value with
.
(
Initial value
:
0
)
Press
to validate it.
3.
Press
twice to go back to the indicated
value display.
6
EXPLANATION OF
COMPARISON FUNCTIONS
Ch1 Ch
2
H I
LO
H I
LO
FNC
Hold section
Hold mode
H I
Ch1 Ch
2
OK
LO
PEAK
HOLD
H I
LO
H I
LO
0
0
0
1
Calculation mode
Auto reset
0
:
ch1+ch2
1
:
ch1-ch2
2
:
|ch1-ch2|
3
:
High select
4
:
Low select
《
Setting Value
》
ESC