Sageon Shield Standalone Battery Monitor

 

 

 

PM990-4023-01, Issue 4 

27 

7.

 

SETTING UP NETWORK INTERFACES 

7.1.

 

PROGRAMMING IP ADDRESSES USING DEVICE INSTALLER SOFTWARE 

This is the simplest way of programming the interface operating parameters; no high level of computer skills is 
required.  Device Installer is a software utility package developed by Lantronix.  It includes a number of handy 
tools making programming of various parameters and firmware update very easy. The installation package is 
available for free download from Lantronix.  At the time of publication, it was located at following Web address: 

http://www.lantronix.com/support/downloads/?p=DEVICEINSTALLER

 

Run DeviceInstaller.exe. You will be guided through the installation process.  This utility is also included on the 
Sageview Installation/Documentation CD that is included with the Standalone Battery Monitor. 

7.1.1.

 

Preparations for local address set up 

 

From your network administrator obtain the new IP address. Also, ask for your network class. 

 

Connect PC to the controller’s network interface (directly or via a network). 

 

Power-up the controller. 

 

Start Device Installer program. 

7.1.2.

 

Local IP address set up procedure 

 

On Device Installer tool bar, click “IP” button. A new window “Assign IP Address” will open. 

 

Enter the unit Ethernet address/MAC ID as stated on information label. 

 

Enter assigned new IP address. 

 

Select correct network class. 

 

Click “Set IP Address” button. 

The process takes several seconds to complete and the progress is indicated below IP address field. When 
completed, a dialog box will pop-up showing a success message, or the one below. 
 

 

 
Often it is a false alarm. To verify if the unit has in fact been programmed, do following: 

 

On Device Installer tool bar,  click “Search Network” button (first on the left hand side). A new 

window “Search Network for Devices” will open 

 

In the new window check selection of the network class, then click “Start Search” button. After search 

is completed, check the window for address you just tried to program (there may be many addresses 
listed). 

 

If the new address is listed, click “Save” button. Details of new device will be added to the Device 

Installer data base. 

 

If the new address is NOT listed, repeat the programming procedure. 

7.1.3.

 

Preparations for gateway address set up 

 

From your network administrator obtain the gateway IP address 

 

Connect a PC to the controller’s network interface (directly or via a network). 

Содержание Sageon Shield 103-4023-01

Страница 1: ...one Battery Monitor Installation Setup Guide For 103 4023 01 PM990 4023 01 Issue 4 UNIPOWER LLC 3900 Coral Ridge Drive Coral Springs FL 33065 Phone 1 954 346 2442 Toll Free 1 800 440 3504 Web site htt...

Страница 2: ......

Страница 3: ...the carrier notes this on your receipt before you sign for the freight 2 EQUIPMENT INSPECTION 2 1 Within fifteen days open the crate and inspect the contents for damages While unpacking be careful no...

Страница 4: ...ssion of UNIPOWER LLC is prohibited Copyright UNIPOWER LLC 2015 DISCLAIMER Data descriptions and specifications presented herein are subject to revision by UNIPOWER LLC without notice While such infor...

Страница 5: ...N TO THE SBM 7 5 2 BATTERY CELL LEAD CONNECTION TO THE SBM 8 5 3 DIP SWITCH SELECTION OF CELL VOLTAGES 17 5 4 DIP SWITCH SELECTION OF ADDRESS 17 5 5 SYSTEM SETUP FOR SBM 17 5 5 1 Relationship between...

Страница 6: ...elay board connections 4 Figure 9 Battery sense wire and current limiting protection heat shrink not shown 7 Figure 10 Battery terminal adapter 7 Figure 11 Battery monitor PCB 8 Figure 12 SBM connecti...

Страница 7: ...ys will trip on high battery cell voltage low battery cell voltage high cell voltage deviation low cell voltage deviation and high ambient or battery temperature Figure 1 Sageon Shield Standalone Batt...

Страница 8: ...insulated tools and other measures to prevent accidental short circuits to the DC bus Figure 3 Opening top rear cover to access wiring All connections to the Sageon Shield Standalone Battery Monitor a...

Страница 9: ...4 way ribbon 4 Ambient temperature sensor connection sensor P N 385 5941 03 5 Battery temperature sensor connection sensor P N 385 5941 03 6 Rectifier isolated communications connection 10 way ribbon...

Страница 10: ...zone The battery temperature sensors are connected directly to the battery posts using the integral lug of the temperature sensor The temperature sensors are galvanically isolated from the lug NOTE U...

Страница 11: ...terminals X2 and X9 respectively Connect the black wire to the battery terminal and the red wire to the battery terminal to complete the power connections to the Sageon Shield The system voltage is s...

Страница 12: ...ltage free contacts or via the USB port which can connect directly to a PC locally or remotely via SNMP and an Ethernet connection 3 1 MAIN FEATURES OF THE SBM BOARD Up to 24 cells can be monitored by...

Страница 13: ...gh rate Continue only when the battery string is at float or disconnected from the charging system 1 Note the battery configuration and select the appropriate figure from section 4 2 of this manual 2...

Страница 14: ...repeat the connection method for batteries 3 and 4 WARNING Sense leads which are connected to the battery string pose a short circuit hazard Each connection to the SBM should be made BEFORE connecting...

Страница 15: ...15 C18 C17 C16 C19 C14 C13 J9 BATTERY SAGEON C13 C12 C11 C10 C9 C8 C7 C6 C12 C11 C10 C9 C8 C7 C6 C5 IN FOR J2 C5 C4 C3 C2 C1 C4 C3 C2 C1 Not used if link in place Cell 20 Cell 21 Cell 22 Cell 23 Cell...

Страница 16: ...C22 C19 C20 C21 C16 C17 C18 C13 C14 C16 C15 C13 C14 C15 J3 REMOVE LINK Connects J2 C12 to J3 C13 48 VOLT BATTERY 2 12 x 4 VOLT MONOBLOCKS MONOBLOCK 2 MONOBLOCK 3 MONOBLOCK 4 MONOBLOCK 5 MONOBLOCK 6 M...

Страница 17: ...GEON C13 C12 C11 C10 C12 C11 C10 C9 C8 C7 C6 C5 C8 C9 C7 C6 IN FOR J2 C4 C3 C2 C1 C5 C4 C3 C2 C1 MONOBLOCK 1 MONOBLOCK 2 MONOBLOCK 3 MONOBLOCK 5 MONOBLOCK 6 MONOBLOCK 7 MONOBLOCK 8 MONOBLOCK 4 48 VOLT...

Страница 18: ...18 C20 C21 C22 C19 C20 C21 C16 C17 C18 C13 C14 C16 C15 C13 C14 C15 J3 REMOVE LINK Connects J2 C12 to J3 C13 MONOBLOCK 2 MONOBLOCK 3 MONOBLOCK 4 4 x 12 VOLT MONOBLOCKS 48 VOLT BATTERY 3 MONOBLOCK 4 MON...

Страница 19: ...C11 C12 C12 C13 J2 IN FOR 24 CELLS J9 SAGEON BATTERY MONITOR 24 VOLT BATTERY 1 12 x 2 VOLT CELLS C23 C24 C24 C22 C23 C17 C19 C18 C20 C21 C22 C19 C20 C21 C16 C17 C18 C13 C14 C16 C15 C13 C14 C15 J3 REM...

Страница 20: ...16 C19 C14 C13 J9 BATTERY SAGEON C13 C12 C11 C10 C12 C11 C10 C9 C8 C7 C6 C5 C8 C9 C7 C6 IN FOR J2 C4 C3 C2 C1 C5 C4 C3 C2 C1 MONOBLOCK 1 MONOBLOCK 2 MONOBLOCK 3 MONOBLOCK 5 MONOBLOCK 6 MONOBLOCK 4 24...

Страница 21: ...C18 C20 C21 C22 C19 C20 C21 C16 C17 C18 C13 C14 C16 C15 C13 C14 C15 J3 REMOVE LINK Connects J2 C12 to J3 C13 MONOBLOCK 2 MONOBLOCK 3 MONOBLOCK 4 4 x 6 VOLT MONOBLOCKS 24 VOLT BATTERY 3 MONOBLOCK 4 MON...

Страница 22: ...12 VOLT MONOBLOCKS C23 C24 C24 C22 C23 C17 C19 C18 C20 C21 C22 C19 C20 C21 C16 C17 C18 C13 C14 C16 C15 C13 C14 C15 J3 REMOVE LINK Connects J2 C12 to J3 C13 MONOBLOCK 2 2 x 12 VOLT MONOBLOCKS 24 VOLT B...

Страница 23: ...ber 1 Switch Number 2 Switch Number 3 Switch Number 4 First ON OFF OFF OFF Second OFF ON OFF OFF Third OFF OFF ON OFF Fourth OFF OFF OFF ON 5 5 SYSTEM SETUP FOR SBM 5 5 1 Relationship between SBM Batt...

Страница 24: ...hat are being monitored for their currents Num Batteries and SBM Batteries are not related except that value entered for Num Batteries must be greater or equal to SBM Batteries This is because Num Bat...

Страница 25: ...ons are to be viewed using this computer station be sure to uncheck Use Home IP address and configure the setup for each Sageon under Connection Phone Book The standalone battery monitor comes equippe...

Страница 26: ...le sites by checking Editing Enabled and adding regions and branches to your Phone Book NOTE The default IP address of the Sageon Shield Standalone Battery Monitor is 192 168 10 60 Refer to section 6...

Страница 27: ...matches the Access Code of the Sageon system you are trying to connect After configuration of your network is complete choose the site to which you wish to connect and click Connect in the Phone Book...

Страница 28: ...ameters Set the Number of RECTs equal to zero Set the desired alarm threshold levels for system voltage EQ Enable should be unchecked EQ Per should be unchecked Bat Disch Test SMR Sleep Mode AC1ph and...

Страница 29: ...the maximum is 4 I Bat FSD A is the full scale rating of the current transducer Click the Edit button next to the Bat Mon checkbox Set the proper cell configuration for your system Set the number of B...

Страница 30: ...s and the Number of Battery Current Transducers that you have selected clicking View Configuration will show the routing of each battery string through the proper transducer When changes have been mad...

Страница 31: ...tandardized for a battery monitor specific application the relay settings are as follows Relay 1 Cell V High Relay 2 Cell V Low Relay 3 Cell dev High Relay 4 Cell dev Low Relay 5 General Alarm The rel...

Страница 32: ...Sageon Shield Standalone Battery Monitor PM990 4023 01 Issue 4 26...

Страница 33: ...Start Device Installer program 7 1 2 Local IP address set up procedure On Device Installer tool bar click IP button A new window Assign IP Address will open Enter the unit Ethernet address MAC ID as...

Страница 34: ...dr 192 168 000 098 no gateway set Channel 1 Baudrate 09600 I F Mode 4C Flow 00 Port 10001 Remote IP Adr none Port 00000 Connect Mode C0 Disconn Mode 00 Flush Mode 00 Change Setup 0 Server configuratio...

Страница 35: ...ARP table using the intended IP address and the hardware address MAC address of the unit which is found on the rear of the unit arp s 191 12 3 77 00 20 4A xx xx xx Notes i The IP address used here is...

Страница 36: ...d communicate with the Sageon CSU unit via the internal serial port The unit s configuration is stored in nonvolatile memory NVRAM and is retained without power You can change the configuration at any...

Страница 37: ...todetect IP addr 192 168 000 098 no gateway set Select 0 and press Enter to configure the Lantronix Interface Server s basic parameters IP Address The IP address must be set to a unique value in your...

Страница 38: ...bits 11111111 11111111 11111111 11110000 255 255 255 224 5 bits 11111111 11111111 11111111 11100000 255 255 255 192 6 bits 11111111 11111111 11111111 11000000 255 255 255 128 7 bits 11111111 11111111...

Отзывы: