background image

The conductive gel sheet can evenly conduct the energy of 
the electrode area to the skin.  It’s essential to paste the gel 
sheet to the conductive rubber before using it.

10

Apply the conductive gel sheet before use

Identify the direction of

 the protective film

 Understand the protection film have A & B 

side. 

 A side: blue printing protective film, peel off 

and stick to the device. 

B side: transparent protective film, which is to be 

removed after the gel sheet attached to the 
conductive rubber.

After removing the A side blue printing 

protective film, align the conductive gel sheet 
to the electrode area of the body and attach it 
tightly. 

● 

When attaching, a slight deviation does not 

affect normal usage. 

 After it’s attached, slightly pressurize the 

fingertip to expel air bubbles and closely fit to 
the conductive rubber. 

 Remove the B side transparent protective film, 

now it’s ready to use.

 The new conductive gel is very sticky. You can 

use your finger to pat a while before wearing it 
to reduce the excessive adhesion level.

●  

What should I do if I accidentally paste the gel sheet on crooked? If 

the deviation from the alignment is more than 3mm, we recommend 
that it be re-attached. At this moment, together with the transparent 
film, try to carefully peel it off slowly with the protective films, level 
them evenly and paste again. 

●  

 Do not use damaged, degraded, or excessively dirty conductive gel 

sheets. It may cause burns to your skin

Содержание UPAD ES-909

Страница 1: ...Model ES 909 MANUAL...

Страница 2: ...ge content 6 Operation interface 7 Preparation before use 8 Product instructions 10 Cleaning maintenance method 13 Optional product contact info 15 Q A 16 Troubleshooting 18 Product spec 19 Product an...

Страница 3: ...all parts of the body Also it s built in with a dedicated training program for exercising the muscle Upad product features Dual machine training system Round rectangular shape makes it easy to attach...

Страница 4: ...service warranty is attached to the last page of this instruction manual When you buy the product please make sure the dealer includes the Purchase Date Dealer Name on the warranty card Keep them safe...

Страница 5: ...that should be followed for safety This symbol indicates prohibited actions This symbol indicates precautionary measures This symbol indicates mandatory actions or instructions This symbol indicates...

Страница 6: ...racture sprain pulled muscle etc Persons with a bone disorder such as osteoporosis Persons who need rest Persons experiencing any specific physical abnormalities Persons receiving treatment from a med...

Страница 7: ...racture sprain pulled muscle etc Persons with a bone disorder such as osteoporosis Persons who need rest Persons experiencing any specific physical abnormalities Persons receiving treatment from a med...

Страница 8: ...surface of the gel sheet and you may feel a strong stimulus or pain Turn off the product before removing the gel sheet Always adhere the gel sheet to the electrodes when using the product Do not touc...

Страница 9: ...C C D E F G Storage bag 1 Gel sheet 2 User manual After sales service warranty x1 Adaptor x1 Cable x1 D Main device A B E F G C A Main device x 2 D Accessories A B B Charging storage stand Package con...

Страница 10: ...ice Front Device Back Storage stand Front LED light Charging terminal Electrode area USB charging inter Charging terminal EMS level up Power on button EMS level down Power off button Operation interfa...

Страница 11: ...nected Plug the power adapter into a charging socket and start charging The LED indicator of the device will flash green light When charging is complete the LED will turn to constant green light Disco...

Страница 12: ...and attach it tightly When attaching a slight deviation does not affect normal usage After it s attached slightly pressurize the fingertip to expel air bubbles and closely fit to the conductive rubber...

Страница 13: ...re environment the battery performance deteriorates and the number of uses may be lower than the standard number of uses Limbs Shoulder lease ensure that it s attached to the skin in a straight along...

Страница 14: ...will hear a long beep indicating that it s is powered on After long pressing the power key for 1 5 seconds to hear a long beep it ll turn off the power When the power is on if the conductive gel does...

Страница 15: ...maining battery capacity is too low please charge it immediately When the intensity reaches the maximum or minimum level it will beep twice For the first time user please start with the lowest intensi...

Страница 16: ...ity environments in cars etc as well as to keep away from direct sunlight Please store in a place that has low humidity If it is placed in a high humidity environment such as a bathroom it may cause m...

Страница 17: ...o the storage stand 1 Before maintenance please make sure that the power is turned off as there may be a risk of electric shock 2 Never rinse the device 3 Never use paint thinner detergent or alcohol...

Страница 18: ...ry it will affect the life cycle of it After using the product keep it in the dedicated storage bag If you feel stinging pain discomfort during the usage please replace the gel sheet immediately 1 It...

Страница 19: ...e sure to use the conductive gel sheet that is dedicated for this product Misuse of non original conductive gel sheet may result in poor conductive effect on this product Please be noted that the comp...

Страница 20: ...ed A3 Wipe the device with a dry fabric For the maintenance method of conductive gel and electrode surface please refer to the topic Clean Maintenance method Q4 What intensity should I use A4 For the...

Страница 21: ...ot use this product during the sleep Q9 Will use this product cause muscle pain A9 This product have the similar effect like the fitness equipment so it may cause muscle pain when overuse it If you fe...

Страница 22: ...y exhausted Issue Solution Recharge the battery Hold the button down until the product beeps 1 5 seconds Use in the recommended temperate range of 15 to 35 degree celsius Fit the electrode area close...

Страница 23: ...e gel Please replace a new gel sheet Push the center area to make it attach to the neck s skin Fit the electrode area close to the skin Please replace a new gel sheet Adjust the intensity to a comfort...

Страница 24: ...utes Auto shut down 10 40 C Humidity 30 85 10 35 C 0 40 C Humidity 30 85 L 151mm x W 75mm x H 10 6mm Approximately 23 4g China Model Adaptor spec Battery spec Battery capacity Charger spec Frequency P...

Страница 25: ...t with items such as necklaces and hairpins Do not place it near a fire source or in a high temperature place such as a flame environment Warning Please make sure the removed lithium ion battery is ou...

Страница 26: ...et the wires red and black touch the removed lithium ion battery It may cause a short circuit and cause burns Remove the battery without breaking it The removed battery have to be send to the recyclin...

Страница 27: ...riod After the warranty period Please contact your source of purchase to obtain the following information Purchase date Product model name Failure status Please be specific If it can be diagnosed and...

Страница 28: ...rd is not presented 6 The warranty card does not include the date of purchase customer s name address or dealer s name If the wording has been modified warranty may be affected 7 Failures and damages...

Страница 29: ...y certificate and proof of purchase receipts etc confirming the date of purchase during the warranty period and contact with the local agent or importer s customer service center for repairs Ensure th...