3.7.6. ETC. (

Thermal

 
This product is an additional device to primarily check whether or not the skin temperature 

rises for unspecified people. 
 

Since it is possible to quickly check whether the skin surface temperature of the test target 
is higher than the normal skin surface temperature, a large number of people can be 
quickly tested, but since disease or virus cannot be identified, the first selected test target 

must be tested as a second test through a medical device. Please follow-up by 
implementing it. 

 

(1) It is recommended that the sensor and face of the product are installed in parallel. (If the face is 

not located in parallel, an error of 1 degree may occur.) 

(2) Errors may occur depending on the type of lighting. (Errors may occur when incandescent lamps / 

halogens / quartz / tungsten are installed.) 

(3) If there are accessories or obstacles covering your face, errors may occur. (Glasses / Hats / when 

the bangs cover the forehead / Headband, etc.) 

(4) Please move an object that can reflect infrared rays on the background staring at the product's 

sensor. (Glass / Mirror / Metal surface, etc.) 

(5) If there are some air conditioners or heaters and etc. in the installed place, errors may occur. 

(Errors occur in the case of air conditioners or near blowers for air conditioning in buildings.) 

(6) It is recommended to install and operate within the temperature range of 20 to 24 degrees / 10% 

to 50% humidity. 

(7) It is recommended that only one person detects fever at a time. 

(8) For accurate temperature measurement, it is recommended to use black body together. 

 

 

 

 

From the main menu, select 

[Terminal] 

 [ETC.(Thermal)]

 to display the screen 

below. 

 

 

 

Default setting: Same as left picture 

 

 

thermal Camera Use 

  When  checking  (

)this  option,  you  can  use  the 

thermal camera. 

 

-  TI  :  When  you  equip  the  thermal  camera  as  the 

bracket type, select this option. 

 

- TI[SG] : When you equip the thermal camera in the 

steel  box,  select  this  option  to  install 

in the speed gate and etc.   

 

-  TS  :  When  you  equip  the  thermal  module  as  the 

bracket type, select this option. 

Содержание UBio-X Face Premium

Страница 1: ...Copyright 2000 By Union Community Co LTD UBio X Face Premium User Guide Version kor 1 0 ...

Страница 2: ... 12F Munjeong Daemyeong Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr Revison History Version Date Description Firmware Version 1 0 2022 02 18 Initial Release ...

Страница 3: ...er ID or card 1 N Authentication 1 to N Identification It s a way to find the user with just a fingerprint It is called 1 N authentication because it is a method of finding the same fingerprint as the input fingerprint among registered fingerprints without entering a user ID or card Authentication level Depending on the face matching rate it is displayed from 1 to 9 Authentication is successful on...

Страница 4: ...21 2 2 1 Standalone use Access 21 2 2 2 Connected with Server Access Attendance Meal amnagement 21 2 3 Product specification 22 3 Environment setting 23 3 1 Checking points before setting the environment 23 3 1 1 Entering the menu 23 3 1 2 Administrator authentication 23 3 1 3 How to enter the menu without administrator authentication 24 3 1 4 How to save the setting values 25 3 2 Menu composition...

Страница 5: ...9 3 7 Terminal 61 3 7 1 Sound 61 3 7 2 Option 62 3 7 3 Input 63 3 7 4 Lock 65 3 7 5 External Device 66 3 7 6 ETC Thermal 68 3 8 화면설정 72 3 8 1 Theme 72 3 8 2 Camera 73 3 8 3 Language 74 3 8 4 LCD option 75 3 8 5 Message display time 75 3 9 Terminal Info 77 3 9 1 System 77 3 9 2 Terminal 78 3 9 3 Network 78 3 9 4 User 79 3 9 5 Log 80 3 9 6 About 81 3 10 SD Card 82 3 11 Download the user file 85 3 11...

Страница 6: ...m User Guide 6 UNIONCOMMUNITY Co Ltd Address 12F Munjeong Daemyeong Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr ...

Страница 7: ...direct sunlight It may cause deformation or color change Avoid high humidity or dust The terminal may be damaged Avoid using water benzene thinner or alcohol for cleaning It may cause an electric shock or fire Do not place a magnet close to the terminal The terminal may break down or malfunction Do not contaminate the fingerprint input area Fingerprints may not be well recognized Avoid using insec...

Страница 8: ...yeong Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 1 2 Specific names of the terminal IR LED Card sensing area Touch LCD USB Input Dual camera Illumination sensor Speaker Mic ...

Страница 9: ...i Status None There is no connected Wi Fi dongle Wi Fi connection is not activated Wi Fi connection is activated Illumination Detection None Detect the high illumination status Detect the low illumination status Fire Alarm Fire Alarm is activated on connecting Fire detection sensor Menu button ID input button Camera video display Current time Function keys Icon for network status Icon for door sta...

Страница 10: ...rmal status Tamper switch is activated Terminal is disassembled Door Status Door status is not sensed Door is closed Door is opened Door is opened abnormally Network Status LAN cable is not connected Disconnected to the server Connected to the server Thermal sensor status None The use of thermal sensor is disabled The use of thermal sensors is active When thermal camera has some error to activate ...

Страница 11: ...488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr When authentication is failed When unregistered user ID is entered When unregistered card is entered Passback error when using anti passback function When using for meal management When a user tried the authentication more than twice in one meal time when using as meal management ...

Страница 12: ...oncomm co kr When the server does not respond during the authentication attempt to the server When the network is disconnected during the authentication attempt to the serve Registration without authentication right or authentication attempt when the entrance is not permitted When the user is designated in the blacklist When the terminal is set locked When it is not the meal time when setting in t...

Страница 13: ...Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr The waiting status for the input of user ID The waiting status for the input of password The waiting status for the input of fingerprint ...

Страница 14: ... kr http www unioncomm co kr The waiting status for the input of card When the terminal program is being upgraded In this state you should not turn off the terminal If the elevated skin temperature is less than 37 5 it shows the Success message for authentication If the elevated skin temperature exceeds 37 5 it shows the Failed message for authentication If the user doesn t wear the mask this mess...

Страница 15: ...zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr f the user doesn t wear the mask properly this message is shown Ex If the user wears the mask under the nose The waiting status to measure the user s temperature If the user is out of the temperature checking area this message is shown ...

Страница 16: ...egister and authorize the face properly Face registration method Maintain the distance between the terminal and face in about 50 cm Locate the face in the guide line of LCD window Register the face pose along with the guidance During the shooting please maintain the attention When registering the face register after sweeping your hair up not to hide the eyebrow or lower face with your hair or hat ...

Страница 17: ... the fingertips is not the right way to register input Make sure the center of your finger touches the window Please be cautious that you may result in low temperature burns when inserting finger If possible please enter the fingerprint of your index finger If you use your index finger you can enter your fingerprint accurately and stably Check if your fingerprint is unclear or damaged It is tricky...

Страница 18: ...nctions together Walk through product and face authentication is possible by passing and staring at the camera FHD 2M Display resolution is adapted Live detection feature with Dual Camera Color IR RF 125kHz and Smart Card 13 56MHz can be used at the same time Easy authentication with the face and fingerprint Can prevent the hazard factors such as forgetting password losing the card or key or steal...

Страница 19: ...ingerprint authentication Fingerprint authentication after ID input if failed password authentication is possible Fingerprint Password Fingerprint password registration Password authentication after fingerprint authentication ID input Fingerprint authentication Password authentication Card or Face Card face registration Card or face authentication Face authentication after ID input Card Face Card ...

Страница 20: ...int and password authentication after card authentication ID input Card authentication Fingerprint and Password authentication Card Face Password Card face and password registration Face and password authentication after card authentication ID input Card authentication Face and password authentication Card Fingerprint Face Card fingerprint and face registration Fingerprint and face authentication ...

Страница 21: ...m co kr 2 2 Product components 2 2 1 Standalone use Access 2 2 2 Connected with Server Access Attendance Meal management TCP IP Meal management program in cafeteria Attendance management program Internet WAN LAN TCP IP Fingerprint authentication server Static IP UDB server Database MDB or MSSQL TCP IP Remote management program user and terminal setting management TCP IP TCP IP TCP IP DC15V Adapter...

Страница 22: ... 000 Finger 1 N 1 100 000 20 000 Face 1 N 1 20 000 10 000 000 Log 20 000 Image Log Fingerprint sensor Optical Scan Area Resolution 20 20mm 500 DPI Temperature Humidity 20 60 Lower than 90 RH AC DC Adapter INPUT Universal AC100 250V OUTPUT DC 12V Option DC 24V UL CSA CE Approved Lock Control EM Strike Motor Lock Auto Door I O 4 In 1 Exit 3 Monitor 2 Out Lock Control together Communication Port TCP ...

Страница 23: ... www unioncomm co kr SIZE 88 0mm 175 0mm 43 4mm 3 Environment setting 3 1 Checks before setting the environment 3 1 1 Entering the menu If you click the icon at the basic window you can enter the main menu window as follows You can enter the subdivision menu by clicking each button 3 1 2 Administrator authentication If the administrator is registered the following administrator authentication wind...

Страница 24: ...and you can access to all the menu until you quit the main menu Fig 3 2 3 1 3 How to enter the menu without administrator authentication It is how to enter the menu when the face authentication is impossible because the administrator card registered in the terminal was lost or there is no administrator Open the cover by removing the bracket at the backside of the terminal With the opened cover con...

Страница 25: ...ales unioncomm co kr http www unioncomm co kr 3 1 4 How to save the set values If you click the Complete button at each menu to save the changed value after the change of settings the set value of the window is saved and the following message box appears If there is no changed value the window is moved to the previous menu If there is no changed value the window is moved to the previous menu ...

Страница 26: ...e All 5 View 2 Network IP address Static IP DHCP IP address Subnet Mask Gateway DNS DNS server1 DNS server 2 Server IP Server IP Port Terminal ID Terminal ID 3 Application 1 Application Access TnA Meal 1 When setting Access or TnA Schedule F1 Attend time F2 Leave time F3 Out time F4 In time Access time Blocking Time 2 When setting Meal Schedule Breakfast time Lunch time Dinner time Supper time Sna...

Страница 27: ...e 2 Finger 1 N Level 3 9 1 1 Level 1 9 Fake Finger Detection FP template format Check similar FP Multi FP Enable 1 N 3 Face Enable 1 N 1 4 Face Size Multi Face Detection Mask Detection AE flicker frequency 0 50 60 Liveness Detection Level 0 9 Led light 4 Auth Auth Type QR Scan Mode 5 Date Time Time synchronization Display Format Set Date Set Time 6 Database 1 Delete all users 2 Delete setting 3 De...

Страница 28: ...k1 duration ms Lock2 duration ms 5 External Device RS232 RS485 Wiegand Site Code Wiegand Output Wiegand Input 6 ETC Thermal Thermal Camera Use thermal mode Display Fever temperature Measurement mode Temperature around 6 Display 1 Camera Save Option Save success log Save failed log Save failed face 0 5 2 Language Language 3 LCD Option Power saving mode Display Option Touch Calibration 4 Message dis...

Страница 29: ... Card 1 Export 1 User Data 2 Event Log 3 System Option 4 Export All 5 Picture 2 Import 1 User Data 2 System Option 3 Others 1 Theme 2 F W Upgrade 3 3 User Management When you select User at the main menu the following window appears The number of all the users is shown at the top of screen including administrator Click Add button to add the new user Modify button to modify the user Delete button t...

Страница 30: ... ID which is already registered the failure message appears and if the ID is not registered the following screen appears The icons in the left side mean as follows The number of registered faces The number of registered fingerprints X 1 10 Existence of password registration X None 1 Registered The number of registered cards X 1 10 User ID to register User Administrator Button Take a picture of the...

Страница 31: ...nal and can register modify delete the information of all the saved users so be careful to register the administrator 3 3 1 1 Photo registration Register by clicking button at the Add User screen Click the Save button to register with the present camera image Click Cancel or BACK button to cancel the registration and return 3 3 1 2 Name registration Register by clicking Name button in the Add User...

Страница 32: ... screen appears If you register the multiple fingers the fingers already registered are represented by blue circle If you register the multiple fingers the fingers already registered are represented by blue circle If you select the finger already registered the following message appears and if you select the re registration you can register again with deleting previously registered fingerprint Whe...

Страница 33: ...he message Register FP put your finger on the input screen and wait for 2 3 seconds until the light is turned off When the message Enter the same fingerprint again appears enter the same fingerprint again In the second fingerprint input after the first fingerprint you should take off your finger from the screen once and input again The message of the left side appears when the input is completed I...

Страница 34: ... return to the upper menu You can register 10 fingerprints at most for one ID and you cannot register more than 10 IDs If the registration was failed at 2 3 times despite the proper fingerprint registration method it is recommended to use face password or card The similar fingerprint check on registration should be verified for the registered fingerprints on the terminal side only If the same fing...

Страница 35: ... www unioncomm co kr 3 3 1 4 Face Registration Register with referring 1 6 How to register and authorize the face properly As shown on the left screen align the red guide that recognizes the face with the center of blue outline and register Press the Start button to register the face As soon as the number on the screen is displayed as 0 the face is registered so please be caution not to blink the ...

Страница 36: ...tration is completed and the screen is moved to the previous screen If you want to register again click Start button to start from the procedure of Basically the feature Similar face check is done at the registration of face but this feature is applied only for the users have the registered face including the Multi Auth users who the option 1 N face use are activated So you have to watch out the f...

Страница 37: ... click OK button the input focus is moved to the password confirm window at below Enter the same password again and click OK button Click button to cancel and return If you enter the different password in the confirm window the message Wrong input appears as follows Duress password When entering a password the authentication is successful even if you enter the password you registered in reverse Bu...

Страница 38: ... Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 3 3 1 6 Card registration Register with clicking Card button in the Add User button Click button to cancel and return If you entered the card already registered the following message appears If a user tried over than 10 registrations the following message appears ...

Страница 39: ...xist v If this option is checked you can authorize only with fingerprint without user ID or card 3 3 1 8 Auth type Set by clicking Auth type at the Add User window But it can be set when there are more than 2 authentication methods registered Click BACK button to cancel and return This shows all the authentication methods already registered and the buttons at the lower side shows the buttons OR AN...

Страница 40: ...shed At this point if you click Cancel or BACK button to return the user is not saved Next is the LCD messages which can appear at the registration procedure When you clicked the Save button the case registration was successful When you clicked the Save button the case registration was failed The case none of authentication methods such as fingerprint face card and password is registered When you ...

Страница 41: ...se the same fingerprint can be authorized as different ID it is not suitable for the attendance management 3 3 2 Delete The following window appears if you click User Delete at the main menu Input the user ID to be deleted and click OK button Click BACK button to cancel and return If you input the unregistered ID the failure message Unregistered user appears and if you input the registered ID the ...

Страница 42: ...p www unioncomm co kr When it is deleted normally When unregistered ID was entered 3 3 3 Modify The following window appears if you click the User Modify in the main menu Input the user ID to be modified and click OK button Click BACK button to cancel and return The failure message appears if you input the unregistered ID and if you input the registered ID the information of registered user is rep...

Страница 43: ...registration X Not registered 1 Registered The number of registered cards X 1 10 User ID to be registered User Administrator If you touch the picture you can register with re taken picture The modification method of each item is the same with the user addition so refer to the 3 3 1 Add 3 3 4 Delete All If you click the User Delete All in the main menu the following window appears If you want to de...

Страница 44: ...r list The list appears in the unit of 100 people and if the list is more than 100 people you can see the previous or next list by clicking BACK or NEXT button ID If you click the ID of specific user you can directly move to the modification window of the user Delete If you check the box of the right side and click the Delete button you can delete all the checked users at once If you click BACK bu...

Страница 45: ...Static IP if the static IP is allocated from the connected network and select DHCP if the IP is allocated from the DHCP server in the connected network If you selected Static IP set the IP address subnet mask and gateway And if you selected DHCP you don t have to set them In Server IP Address enter the server s IP address However if you are using DDNS provided by us you must check DDNS to enter th...

Страница 46: ...ng button or the next input window If you touch the background window which is not the input window the keypad disappears If you want to apply the changes click Save button and return to the previous menu by clicking BACK button Wi Fi When the Wi Fi dongle is connected to the USB port on backward of the UBio X Face Premium device this icon will be come up automatically on the Network screen as sam...

Страница 47: ...ed and then UBio X Face Premium device will be connected to this AP when inputting the proper AP password If you want to apply the changes click Close button and return to the previous menu by clicking BACK button 3 5 Application mode 3 5 1 Application If you select the Application in the main menu the following window appears In the application mode you can select the Access TnA Meal according to...

Страница 48: ... clicking another function button and it is convenient for the TnA management because the indication mode is changed to the set authentication mode automatically though another mode was authorized by clicking another function key The time periods should not be overlapped but if they are overlapped the application order is Attend F1 Leave F2 Out F3 In F4 Access If the time is set between 23 00 01 0...

Страница 49: ... is possible regardless of the previous authentications Click the OK button to apply the changes and click BACK button to cancel and return 3 5 2 Function key The following window appears if you select the Application Function key in the main menu Basic setting Same with the window at the left side Fn Key It means the F1 F4 Access button used to change the authentication mode such as attendance an...

Страница 50: ...de 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr Click the OK button to apply the changes and click BACK button to cancel and return If you select button you can see the added access mode as you set in Extended Key And if you select among F1 to F4 it changes into the selected authentication mode ...

Страница 51: ...t determines the priority of the authentication between the terminal and network server and there are 2 modes Terminal Server and Terminal Only Terminal Server It authorizes the user registered in the terminal as 1 N identification but it authorizes the user in the server as 1 1 verification Terminal Only It only authorizes the user registered in the terminal Mandatory Registration It determines t...

Страница 52: ...l to prevent the fake fingerprint input The higher level of the LFD level the preventing function of the fake fingerprint input such as rubber paper film or silicon is strengthened but the fingerprint also can be hard to enter if the finger is dry too much FP template format It determines the format of fingerprint template When some applications using SDK need another format of the fingerprint the...

Страница 53: ...nts should be authorized after the ID or card input If it is checked the user should input the user ID or card the option Enable 1 N will be unchecked automatically It is the function used when managing the access control of the special area strictly For example if the user with ID 0001 has three fingerprints registered the user should be authorized with all three fingerprints after entering ID In...

Страница 54: ...g this option since only the biggest face can be detected it can be used when one person authenticates at a time such as a speed gate Mask Detection When checking this option a user should wear a mask to authenticate successfully None Do not check for wearing a mask Guide If the mask is not worn or the wearing condition is poor it can authenticate but it shows the guide message about wearing the m...

Страница 55: ...nt the fake faces made of rubber paper film silicone etc but may not work well even when authenticating with a real face Click OK button to apply the set value and click BACK button to cancel and return If you click OK button without changing the set value it is moved to the upper menu automatically 3 6 4 Auth If you select the System Auth in the main menu the following window appears Basic settin...

Страница 56: ...e Though the user is registered with the authentication method requiring the card fingerprint or password in addition to the face in the terminal with the checking of the item the face can authorize by itself For fingerprint face or password users follow the same authentication procedure as per normal to uthenticate 3 6 5 Set the current time If you select the System Date Time in the main menu the...

Страница 57: ...the set value and click BACK button to cancel and return 3 6 6 Database If you select the System Database in the main menu the following window appears If you want to delete all the users click Delete all users button If you want to initialize the settings click Delete setting button If you want to initialize the authentication record click Delete Log button If you want to delete image log only cl...

Страница 58: ...or are deleted and the restoration is impossible once the data is deleted 3 6 6 2 Delete setting If you select the System Database Database in the main menu the following screen appears Click YES button to initialize all the set values and click NO or X button to cancel If there is no signal for 5 seconds in this state the message box disappears without initialization If the deletion is successful...

Страница 59: ...played All the authentication log is deleted including image log and the restoration after the deletion is impossible 3 6 6 4 Delete image log If you select the System Database Delete image log n the main menu the following window appears If you want to delete all the image log record in the terminal click YES button and if you want to cancel click the NO or button If there is no signal for five s...

Страница 60: ...YES button and if you want to cancel click NO or button If there is no signal for five seconds in this state the message box disappears without initialization If it is deleted successfully by clicking YES the success message in Fig 3 5 appears and the display language and voice is changed to the default value English All the set value users and log information besides the MAC address in the termin...

Страница 61: ... side in 0 3 degrees to set the beep volume If you click the button at the right side the beep sound is played to check the volume Sound Option Sound effect The sound effect can be output on authentication success or failed User voice If the user wants to change the voice played when the authentication is successful or failed the user voice can be played if the user copies the sound into terminal ...

Страница 62: ...to the lock until the administrator unlock the setting Card reader You can set Standard or HID iClass and it can recognize the card of setting type Card format It determines the representation method of the card number The card number is changed according to the following settings So if you have to change the card expression method you should register the card again RF card example Card number 5by...

Страница 63: ...ternal access point to the DM0 When using motor lock set Door open NO or Door open NC None When nothing is connected Door open NO or Door open NC When the door open monitoring pin was connected Fire detection NO or Fire detection NC When the fire detection sensor is connected Panic detection NO or panic detection NC When the panic situation detection sensor is connected Emergency detection NO or e...

Страница 64: ...cted Emergency detection NO or emergency detection NC When the emergency situation detection sensor is connected Set NO NC according to the state of pin input in detection Warn door open sec This function alarms when set time for door open 5 30 seconds is passed with the opened door If it is set 0 no alarm is ringing and though you set 01 04 the alarm will ring after 5 seconds This function enable...

Страница 65: ... the operating signal about it Duress alarm When the fingerprint registered as a duress FP is authenticated Lock2 Option None When it is not used Strike Auto OK When the warning light is connected to indicate the strike type auto door or authentication success failure on Lock2 Motor lock 2 When the motor lock is connected Regular notification When the siren setting of the terminal option was sent ...

Страница 66: ...to the RS232 port Ticket Format1 Ticket Format2 The authentication result is printed when the authentication is successful The terminal ID user ID authentication time and authentication mode are printed by the printer connected to the RS232 port The printing format differs as per the setting and when setting as Ticket Format2 the text for meal printer which was set from the terminal option becomes...

Страница 67: ...6bit It is used only when the special controller is equipped running by the Wiegand input When the authentication is finished the data of the following format is sent to the Wiegand port of the terminal Send example In case of SiteCode 045 2Dh UID 6543 198Fh 1 00101101 0001 1001 10001111 0 34bit Because it sends Site code 1 byte User ID 3 bytes set the user ID less or equal than 7 digits But if th...

Страница 68: ...uartz tungsten are installed 3 If there are accessories or obstacles covering your face errors may occur Glasses Hats when the bangs cover the forehead Headband etc 4 Please move an object that can reflect infrared rays on the background staring at the product s sensor Glass Mirror Metal surface etc 5 If there are some air conditioners or heaters and etc in the installed place errors may occur Err...

Страница 69: ...ut window appears after detecting the elevated skin temperature After entering the phone number the authentication result is displayed and the user is automatically registered Display Select Celsius Fahrenheit or None If you select None 4 of authentication results are displayed as below Authentication result Details LOW If the user s temperature is less than 30 C HIGH If the user s temperature is ...

Страница 70: ...w If your environment has the low temperature use Low thermal setting If you set the square box is displayed to show the available area to authenticate If you set the preview video is displayed at the bottom of right side If the face is included in the authentication area it is possible to check if the user has the standard temperature or not While the temperature is checked you can see the therma...

Страница 71: ...ail sales unioncomm co kr http www unioncomm co kr For the registered user it checks the user s temperature and shows the temperature with the authentication success message For this it should set Reguser from thermal mode For the unregistered user it checks the users temperature without the registered image after authentication success For this it should set UnReguser from thermal mode ...

Страница 72: ...ode 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 3 8 Display 3 8 1 Theme If you select Display Theme in the main menu the following window appears Basic setting Same with the window at the left side Background Since the camera is basically displayed it is not available to select the background ...

Страница 73: ...e displayed in the message window of authentication success None Registered photo Authentication method Image stands for each authentication method Save success log If it is checked the camera image is captured as image log when the authentication was successful Save failed log If it is checked the camera image is captured as image log when the authentication was failed Save failed face 0 The fail...

Страница 74: ... 3 8 3 Language If you select the Display Language in the main menu the following window appears Basic setting English Language If you change the language and click OK button the voice message and language are changed to the set language If you want to cancel and move to the upper menu click BACK button Supporting languages English Korean Japanese Portuguese Chinese Traditional French Chinese Simp...

Страница 75: ...CD is always turned on Display Option It sets what will be shown at the LCD screen when the authentication is successful None The authentication result Success Failure is only represented User ID User Name Representing user ID if it is not registered In this case added ID in order to differentiate with name Social No Representing user ID if it is not registered In this case added ID in order to di...

Страница 76: ...omm co kr Basic setting Same with the window at the left side Message Display ms It sets the time for which the authentication result window to be displayed 0 5000 is available for the value and the authentication result window appeared and disappear for the duration Because it is set in millisecond if you want to set 2 seconds you should set 2000 Click OK button to apply the set value and click B...

Страница 77: ...in the main menu the following window appears System info The hardware and firmware version of terminal is shown Ram using size Total size The using size of RAM among the all size is represented If the using size is high it is represented in red Ram using size Total size The using size of RAM among the all size is represented If the using size is high it is represented in red Click BACK button to ...

Страница 78: ...sales unioncomm co kr http www unioncomm co kr 3 9 2 Terminal If you select the Terminal info Terminal in the main menu the following window appears Terminal info It represents the option setting value of the terminal Click Close or BACK button to finish the inquiry and move to the upper menu 3 9 3 Network If you select the Terminal info Network in the main menu the following window appears ...

Страница 79: ...fo User in the main menu the following window appears User User The number of users registered including administrator Admin The number of the administrators registered FP The number of all the fingerprints registered FP 1toN The number of fingerprints which can be authorized by 1 N Face The number of the users who registered the face Face 1toN The number of users who can be authorized by 1 N Card...

Страница 80: ...9 5 Log If you select the Terminal info log in the main menu the following window appears Log Log The number of logs saved in the terminal Image Log The number of logs saved in the terminal The number of logs saved in the terminal View Log Displays log time and authentication result Log Search To search log follow the following steps Terminal Info Log View Log Log Search And then set the Start Dat...

Страница 81: ...ws the information such as the date time ID and access result success or failure Click BACK or NEXT button to see the search information If you want to finish the inquiry and move to the upper menu click Close or BACK button 3 9 6 About If you select the Terminal info About in the main menu the following window appears About It shows the license information applied in the terminal If you want to f...

Страница 82: ...488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 3 10 USB If you select the USB at the main menu the following screen appears When USB is inserted When USB is not inserted Work can only be done when USB is inserted and the back side must be inserted forward as shown in the picture below The size of the USB should not exceed 32G ...

Страница 83: ... data of the terminal via Export You can copy the back up data to the terminal via Import Export It copies the data from the terminal to the external USB User data It copies the user DB to the folder unisuser in USB System option The option setting value of the terminal is copied to the folder UbioXfacePremium config Event log It copies the authentication log DB to the folder UbioXfacePremium Term...

Страница 84: ... option setting value of the terminal is copied to the folder UbioXfacePremium config in the terminal After importing the data you should reboot the terminal to apply the new DB or setting value Others Theme The voice file in the UbioXfacePremium audio folder in the USB is copied to the terminal If you want to replace the authentication success user_ok mp3 and the authentication fail user_fail mp3...

Страница 85: ...nsfer in our server program the following window appears If you select Sound Voice File wav as the file type and click Send button after selecting the sound file wav or mp3 the terminal selecting window appears If you select the terminal in the terminal list window and click the Send button again the file is sent and the result of download appears In this time the file name should be less than 15 ...

Страница 86: ...e changed according to the administrator s setting In addition if the administrator set the screen saver time the LCD screen is turned off automatically if there is no action for set time and when the user accessed to the terminal tried the authentication with card or touched the main screen the LCD screen is turned on automatically 4 1 How to change Auth mode Fig 4 1 Select the function key butto...

Страница 87: ... of face card or password depending on the authentication method of the user 4 3 Authentication 4 3 1 Face authentication 1 N authentication Identification Try authentication by staring at the camera so that the face appears on the LCD screen 1 1 authentication Verification As shown in the following figure enter your ID first by clicking Input ID button and when the face input message appears loca...

Страница 88: ...ingerprint on the fingerprint sensor at the basic window the fingerprint is entered with the light on the sensor with beeping Do not take off your finger until the light of the sensor turns off completely 1 1 authentication Verification As shown in the following figure enter your ID first by clicking the Input ID button and input your fingerprint when the fingerprint entering window appears and th...

Страница 89: ... Seoul Korea zip code 05836 Tel 02 6488 3000 Fax 02 6488 3099 E Mail sales unioncomm co kr http www unioncomm co kr 4 3 3 Card authentication Place the card on the card picture Fig 4 1 4 3 4 Password authentication Input your ID by clicking ID input button as follows and input password when the password input window appears ...

Страница 90: ...s fingerprint Example 1 If the password is 1234 if you authenticate it with 4321 you can authenticate the duress password Example 2 It doesn t apply if the password is a continuous number like 1111 Example 3 It doesn t apply even if the password is a symmetric number like 1221 Example 4 If the password is a single digit number like 1 it doesn t apply 4 3 5 Multi mode authentication For user who ne...

Страница 91: ...ch can be determined by turning the equipment off and on the user is encouraged to try correct the interference by one or more of the following measures 1 1 Reorient or relocate the receiving antenna 1 2 Increase the separation between the equipment and receiver 1 3 Connect the equipment into an outlet on a circuit different from that to which receiver is connected 1 4 Consult the dealer or experi...