UBio-X Face Premium User Guide
65
UNIONCOMMUNITY Co., Ltd.
Address: 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu,
Seoul, Korea (zip code: 05836)
Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :[email protected]
3.7.4. Lock
If you select the
[Terminal]
[Lock]
in the main menu, the following windows
appears.
▶
Basic setting: Same with the window at the left side.A
▶
Lock1 Option
-
None: When it is not used
-
Strike/Auto/OK: When the warning light is connected to indicate the strike type,
auto door, or authentication success/failure on Lock1.
-
Motor lock 1: When the motor lock is connected.
-
Regular notification: When the siren setting of the terminal option was sent to the
terminal, it sends the operating signal about it.
-
Duress alarm: When the fingerprint registered as a duress FP is authenticated
▶
Lock2 Option
-
None: When it is not used
-
Strike/Auto/OK: When the warning light is connected to indicate the strike type,
auto door, or authentication success/failure on Lock2
-
Motor lock 2: When the motor lock is connected.
-
Regular notification: When the siren setting of the terminal option was sent to the
terminal, it sends the operating signal about it.
-
Duress alarm: When the fingerprint registered as a duress FP is authenticated
▶
Lock 1 duration (ms)
When Lock 1 is set ‘Strike/Auto/OK’, it determines the signaling time. Because it is set
in ms unit, if you want to set 3 seconds, you should set 3000. The strike type means
the time until the door is locked again when opening the door after authentication.
.
▶
Lock 2 duration (ms)
It sets the signaling time when Lock 2 is set ‘Authentication failure notification’.