Unimac Airless Paint Sprayer UM-SP-35
7
7
Assembly
Pump Unit
1. Attach carry handle;
a. Remove both bolts on the “handle bar” and set aside.
b. Insert handle into the air prayer frame.
2. Using the bolts from (a) bolt the handle to the frame firmly using a spanner.
3. Attach inlet hose to inlet valve on the front of the “pump manifold” making sure the connection is
secured using a spanner. Be careful not to over tighten.
4. Attach high pressure hose on to the outlet valve.
5. Attach the pressure gauge;
a. Using plumbers teflon tape, run 2-3 layers clockwise around the thread of the pressure gauge.
b. Screw the gauge into the top of the inlet manifold turning clockwise, hand tight plus half a turn
and in a position where the gauge can be comfortably read.
Spray Gun
1. Attach the spray gun (1) to the high pressure outlet hose (2).
2. Attach the extension tube (3) to the spray gun nozzle, if required.
3. Attach the spray tip (4) to the extension tube or spray gun nozzle.
Video Tutorial: