REFERENCE GUIDE
* MXVOLTA battery dischagre performance data
* Storage and manage MXVOLTA batteries
* Troubleshooting flowchart
* List of material for MXVOLTA batteries
* Discharge capacity varies depending on the discharge current & hour rate
* STORAGE AND MANAGE OF MXVOLTA BATTERIES
A. O.C.V manage during storage at 25℃
Passed period
after
manufactured
VT2100
to
VT23000
VT12012
to
VT1224
VT1231
to
VT12200
1 day - 1 month
1 month - 2 month
2 month - 3 month
3 month - 4 month
4 month - 5 month
5 month - 6 month
2.12 ~ 2.11 V
2.11 ~ 2.10 V
2.11 ~ 2.10 V
2.10 ~ 2.09 V
2.10 ~ 2.09 V
2.09 ~ 2.08 V
12.90 V
12.85 V
12.80 V
12.70 V
12.65 V
12.60 V
12.80 V
12.78 V
12.75 V
12.65 V
12.60 V
12.55 V
When passed more than 6 months, refresh charge must be carried out
B. When passed more than 6 months after manufactured, refresh charge
methods are two following
(1) Constant voltage
-------------------------------------------------
setting voltage Initial limit current Charging time
-------------------------------------------------
2.45V/cell 0.25 C 6±1 hour
-------------------------------------------------
(2) Constant current
-------------------------------------------------
setting current Charging time
-------------------------------------------------
0.05 C 6 ± 1 hour
0.1 C 3hour ± 30min.
-------------------------------------------------