General unit data
Mains voltage
AC 230 V +10 % / -15 %
AC 120 V +10 % / -15 %
Mains frequency
50...60 Hz ±6 %
External primary fuse (Si)
6.3A (slow)
Power consumption
12 VA
Mounting orientation
optional
Weight
approx. 200 g
Degree of protection
IP40 (to be ensured through mounting)
Perm. cable lengths
max. 3m at line capacitance of 100 pF/m
Detector cable laid separately
10 m
Remote reset laid separately
20m
LMO14
LMO24
LMO44
Terminal 1
5 A
5 A
5 A
Terminals 3 and 8
3 A
5 A
5 A
Terminals 4, 5 and 10
1 A
1 A
1A
Terminals 6
1 A
1 A
2A
Flame supervision with QRB and QRC
QRB
QRC
Min. detector current required (with flame)
45 µA 70 µA
Min detector current permitted (without flame)
5.5 µA 5.5 µA
Max. possible with flame (tipically)
100 µA 100 µA
Measurement circuit for detector current
Key
µA DC
DC microamperometer with an internal
resistance of 5 k
W
max.
bl
Blue
sw
Black
br
Brown
12
11
LMO...
bl
µA DC
+
QRB...
7130v01/0700
sw
12
11
LMO...
1
sw
bl
br
µA DC
+
QRC1...
7130v02/0700