C.I.B. UNIGAS
- M039135CG
5
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Specifications
Type
NG90
Model
M-. AB. S. .* A. 0. 15
(1)
(2) (3) (4) (5) (6) (7) (8)
(1) BURNER TYPE
NG - Natural gas burner
LG - L.P.G. burner
NGX - Natural gas Low NOx burners
(2) FUEL
M - Natural gas L - LPG
(3) OPERATION
TN - Single stage AB - Double stage
(4) BLAST TUBE
S - standard L - extended
(5) DESTINATION COUNTRY
* - see data plate
(6) BURNER VERSION
A - Standard
(7) EQUIPMENT
0 = 2 gas valves
1= 2 Gas gas proving system (option)
(8) GAS CONNECTION
10= 3/8” = Rp1/2 15= 1/2” = Rp1/2 20= 3/4” = Rp3/4
BURNERS
NG70
M-.TN...10
NG70
M-.TN...15
NG90
M-.TN...10
NG90
M-.TN...15
NG90
M-.TN...20
Output
min. - max. kW
30 - 70
40 - 85
Fuel
Natural gas
Category
(see next paragraph)
Gas rate
min.-max. (Stm
3
/h)
3.2 - 7.4
4.2 - 9
Gas pressure
min.-max. mbar
(see Note 2)
Power supply
230V 1N.ac - 50 Hz
Total power consumption
kW
0.40
Electric motor
kW
0.10
Protection
IP40
Approx. weight
kg
14
Valves size / Gas connection
3/8 / ”Rp1/2
1/2” / Rp1/2
3/8” / Rp1/2
1/2” / Rp1/2
3/4” / Rp3/4
Operation
Single stage
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermittent
BURNERS
NG70
M-.AB...10
NG70
M-.AB...15
NG90
M-.AB...10
NG90
M-.AB...15
NG90
M-.AB...20
Output
min. - max. kW
19 - 68
22 - 85
Fuel
Natural gas
Category
(see next paragraph)
Gas rate
min.-max. (Stm
3
/h)
2 - 7
2.3 - 9
Gas pressure
min.-max. mbar
(see Note 2)
Power supply
230V 1N.ac - 50 Hz
Total power consumption
kW
0.40
Electric motor
kW
0.10
Protection
IP40
Approx. weight
kg
14
Valves size / Gas connection
3/8” / Rp1/2
1/2” / Rp1/2
1/2” / Rp1/2
1/2” / Rp1/2
3/4” / Rp3/4
Operation
High-low flame
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermittent
PART I - INSTALLATION