MSR110D Programmer’s Manual UDN PM008 Rev. D
Section 3 -- Technical Specification 2002/3/19
Page 9
Uniform Industrial Corp.
Proprietary and Confidential
Total 44 pages
Humidity
Operating: 10-85% (non condensing)
Storage:
10-90% (non condensing)
Pin Assignment
Table 3-2. Pin Assignment
DB9
SIGNAL PCB-JP2 SIGNAL
DIRECTION
1
2
RXD
6
TxD
Out to host
3
TXD 4 RxD
In
from
host
4
5
GND 8 GND
6
7
RTS 3 CTS
In
from
host
8
CTS 5 RTS
Out
to
host
9
Note: PCB-JP2-2: VCC IN (5V)
PCB-JP2-7: SHIELD
Communication
Synchronization
The interface receives and transmits serial asynchronous data at voltage levels compatible with the RS232
specification.
Signal
Logic 1 = -3 volts to –15 volts
Logic 0 = +3 volts to +15 volts
Baud Rate
9600 default (optional: 1200/2400/4800/19200)
Transmission Protocol
The user may select from three different protocols: Protocol 0, 1, and 2.
Upon reset, the reader sends the power-on response “:”, depending upon the configuration setting. The reader then
configures itself to the protocol of the first command from the host. From this point on, the protocol is
unchangeable until a reset occurs.