- 26 -
Pro blem
Cause
Ch eck
Solut io n
Page
Nee dle
breakage
Improper needle
installation
Needle facing, height
Reinstall needle.
4
Bent needle
Blunt needle tip
jammed eye
Needle
Replace needle
4
Improper feed timing
_
Adjust feed timing.
16
Improper needle to
rotary hook timing
Needle bar stroke
Adjust needle to rotary
hook timing.
15
Needle bar height
Adjust needle to rotary
hook timing.
15
Needle to rotary
hook gap
Adjust needle to rotary
hook timing.
15
Thread wiper too high
Thread wiper
position
Adjust thread wiper
position with screw.
Thr ead
breakage
Improper threading
Threading
Rethread.
4
Bent needle
Blunt needle tip
jammed eye
Needle
Replace needle
4
Improper needle
installation
Needle facing, height
Reinstall needle.
4
Excessive needle
thread tension
Needle thread
tension
Adjust needle thread
tension.
6
Excessive bobbin
thread tension
Bobbin thread
tension
Adjust bobbin thread
tension.
6
Loose needle thread
Thread take-up
spring operation
Adjust thread take-up
spring.
6
Insufficient rotary hook
lubrication
Oil supply
Adjust oil supply.
2
TROUBLESHOOTING GUIDE
All manuals and user guides at all-guides.com
all-guides.com
Содержание LS2-H550
Страница 2: ...All manuals and user guides at all guides com...
Страница 4: ...5 off A S 31 2 40 25 OFF A S A S All manuals and user guides at all guides com...
Страница 35: ...25 4 4 16 15 15 15 4 4 4 6 6 6 2 All manuals and user guides at all guides com...
Страница 37: ...27 4 4 1 4 4 15 15 15 6 6 All manuals and user guides at all guides com...
Страница 39: ...29 6 6 6 6 puff 15 19 23 4 22 19 23 19 All manuals and user guides at all guides com...
Страница 41: ...31 6 1 22 6 24 24 24 24 All manuals and user guides at all guides com a l l g u i d e s c o m...
Страница 43: ...33 All manuals and user guides at all guides com...