9.:  Set sensitivity: 

Depending on the currently sensitivity value, the positioned object can switch the relay ON via 
the sensor electrodes, or the relay remains switched OFF. The red LED5 lights up to indicate 
when the relay is switched ON. 

In any case, the sensitivity must be set to match the working object as described below. 

 

!

 

For proper functionality, the 

sensitivity

 should only be set 

as high as necessary!

 

 

There are two possible methods of setting the sensitivity: 

 

1.

 

Automatic:

  The evaluation unit adjusts the sensitivity to match the positioned object in  the 

detection area. If the relay was previously switched OFF, it switches on. If it was 
already ON, it will keep ON until the object is removed. 
The procedure is as follows: 

 

 

 

–  Place the object in the detection area. 

 

 

 

–  Press button SW1 for 2s… 3s 

After 2s, LED2 lights up indicating 2s gone. 

 

 

 

–  Release button SW1. 

LED2 goes out. You now have 3 seconds to move away from the area of the 
sensor electrodes, so that, your presence does not influence the measure-
ment of the object. 
When 3s are done, the optimum sensitivity for the working object is set. LED2 
confirms the process by flashing briefly. 

 

2.

 

Manual:

 

– 

Relay OFF (LED5 OFF):

 

Rotate  the  switch  SW1  clock-wise  until  the  relay  switches  ON,  plus  three 
more points. 

 

 

 

– 

Relay ON (LED5 ON): 

 

Rotate switch SW1 anti-clock-wise until the relay switches OFF (LED5 OFF), 
then return until the relay switches ON again (LED5 ON) plus three points. 

 

Case the current sensitivity shows impractical, it can be adjusted manually at any time by turning 
the switch SW1. 
The new sensitivity setting is saved and also effective by the next time the evaluation unit is 
switched ON. 

 

Function Explanation (Turning OFF without memorization)

 

Case the detector device is switched OFF while the memory function is inactive and an object is left 
in the detection area, the device “ignores” this condition. In this case, when the device is switched 
ON again, it will proceed with a new adjustment considering free detection area and the relay will 
stay OFF. 
To be sure about this procedure, one can move his hand to the detection area to see the relay turning 
ON. After removing the object and subsequently the hand from the detection area, the relay turns 
OFF again and around 2s later the new conditions will be detected by the device as empty area. 
 

Содержание S-SW-8

Страница 1: ...manual adjustment switch SW2 2 to OFF 6 2 4 2 Sensitivity setting relay switching point 6 2 5 Technical Data 7 3 Montage Cabling 8 3 1 System arrangement 8 3 2 Electrical connections 9 4 Installation...

Страница 2: ...the sensitivity is set appropriately the presence of the new objects is detected A potential free contact relay turns ON OFF according to the IN OUT movement of objects over the sensing area the swit...

Страница 3: ...Connections Con nector Pin Connection X1 1 24 VAC DC Supply Voltage Both polarity accepted 2 3 PE Reference Potential Connected to the earth X2 1 C Relay common contact 2 NO Relay normally open contac...

Страница 4: ...of the evaluation unit via the shield of the coaxial cable Montage structure C The design of the mounting structure depends on the conditions at the installation place It must be made of conductive ma...

Страница 5: ...switch on point occupied and the switch off point free for the relay The sensor signal level for the switch ON point is stronger than the switch OFF point A larger hysteresis means that the switch ON...

Страница 6: ...ves the reference value of the system The sensor electrodes must be free when performing a new adjustment No objects or person may be near the sensor electrodes SW2 2 OFF Memory OFF After power ON the...

Страница 7: ...n 2 5 Technical Data Parameter Sim Condition min tip max Unit Supply Voltage UV AC DC 18 24 30 V Operation Power IV 18V UV 30V 3 W Environment Tempera ture TF In operation 15 20 55 C TL Storage 20 60...

Страница 8: ...ts to be detected This ensures safe switching behavior The evaluation unit should be installed near the sensor electrodes The sensor line coaxial cable between the evaluation unit and sensor electrode...

Страница 9: ...e 5 Connect the reference potential of the evaluation unit X1 3 direct to the earthed mounting struc ture 6 Connect the supply voltage 24VAC DC to the evaluation unit X1 1 X1 2 7 First operation By th...

Страница 10: ...timum sensitivity for the working object is set LED2 confirms the process by flashing briefly 2 Manual Relay OFF LED5 OFF Rotate the switch SW1 clock wise until the relay switches ON plus three more p...

Отзывы: