13

SALSA Mobile Standing Transfer Hoist Instruction & Safety Manual

T

 08 9351 7500              

E

 [email protected]              

W

 www.unicarehealth.com.au

Warranty

ALLEGRO CONCEPTS PTY LTD warrants its products to be free from defects in materials and 

workmanship under normal use and service and will within the period stated below, from the date of 

purchase, repair or replace without cost to the original customer, any part assembly or portion thereof 

which shall be returned to ALLEGRO CONCEPTS and from OUR inspection shows to be defective.

• 

Patient lifter including electronics 2 years

• 

Accessories on lifter 2 years

• 

Patient slings 1 year

• 

Weighing devices 1 year

• 

Batteries 3 months

ALLEGRO CONCEPTS PTY LTD cannot be held responsible for any personal injury, damage to the 

hoist or damage to property as a result of the improper or unsafe use of the product.

No warranty claim shall apply where the product or any part thereof has been modifi ed, varied, altered 

or damaged either accidentally or through improper or negligent use

No warranty claim shall apply where the hoist is repaired or serviced by any persons not accredited 

by the authorised distributor. Warranty does not extend to items or components which may require 

replacement due to normal wear and tear ( e.g. castors, mouldings and paint work ) for which ALLEGRO 

CONCEPTS nor its distributors can be held responsible.

Batteries

Batteries carry a limited warranty from the original manufacturer which is subject to a stringent wear and 

tear clause. Any battery faults due to defect in original manufacture will normally become apparent within 

the fi rst two months of use.

Any gradual deterioration in performance after this period is normally associated with fair wear and tear, 

misuse and accidental damage, and as such is not covered by the manufacturers warranty.

Содержание SALSA 200

Страница 1: ...SALSA Mobile Standing Transfer Hoist Instruction Safety Manual Please read this manual before operation for maintenance instructions and safe usage The enabling power of applied knowledge...

Страница 2: ...u W www unicarehealth com au Contents Overview 2 Important Saftey Considerations 3 Assembly Instructions 5 Hoist Operation 6 Actuator 6 Charging 7 Charging Indicator Lights 7 Charging Do s and Don ts...

Страница 3: ...d to both home or institutional use The SALSA is an electric operated hoist with ergonomic features designed with the patient and carer in mind An ALLEGRO standing sling speci cally designed for the S...

Страница 4: ...ng task should be assessed planned by a trained user Safety Considerations Ensure all that all users read this guide before operating the hoist Do not operate the hoist without training in the safe op...

Страница 5: ...4 T 08 9351 7500 E info unicarehealth com au W www unicarehealth com au Lift Arms Actuator Knee Pad Leg Battery Pack Push Handle...

Страница 6: ...nut 3 Repeat process 2 for second leg 4 Attach leg adjuster tie rod ends to each leg and tighten each nylock nut 5 Attach lift actuator to lifting arm assembly by aligning actuator clevis with actuato...

Страница 7: ...arrows and symbolised legs indicating the direction of travel This function allows an unrestricted range of leg adjustment The handset is also tted with a battery indicator light This will ash when th...

Страница 8: ...from control box by pulling the handle on the pack towards you Use both hands to support the battery pack when removing or replacing it Clip the battery pack onto the charging unit ensuring it is seat...

Страница 9: ...ty The batteries are not the nickel cadmium type and must not be periodically fully discharged Battery life is greatly reduced by deep or complete discharging of the batteries Longer lifetime is obtai...

Страница 10: ...ance is suf cient to manoeuvre legs under the bed Lower the SALSA lift arms using the handset buttons until sling keyhole buckles can reach and easily engage the studs on the lift arms to prevent poss...

Страница 11: ...gue lubricate and or adjust as required NB leg pivot bushes incorporate a Te on coated pivot bush which requires minimal lubrication Check tightness of bolt in leg bushes Check linkages are secure in...

Страница 12: ...up No mains connection Internal fuse blown Battery chargers is defective Plug into mains Replace fuse Repair replace charger Actuator will not run and no relay click is heard from control box Control...

Страница 13: ...KG BASE LENGTH 1050mm EXTERNAL BASE WIDTH 655mm INTERNAL BASE WIDTH CLOSED 585mm INTERNAL BASE WIDTH OPEN 1035mm BASE WIDTH ADJ ELECTRIC UNDER BED CLEARANCE 125mm MIN HEIGHT OF LIFT ARM 825mm MAX HEIG...

Страница 14: ...the improper or unsafe use of the product No warranty claim shall apply where the product or any part thereof has been modi ed varied altered or damaged either accidentally or through improper or negl...

Страница 15: ...7500 E info unicarehealth com au W www unicarehealth com au Log Book Service Type Condition Report Date Inspection by Signature Action Taken Service Type Condition Report Date Inspection by Signature...

Страница 16: ...PO Box 82 Bentley WA 6982 T 08 9351 7500 F 08 9350 5299 info unicarehealth com au www unicarehealth com au Authorised Distributor...

Отзывы: