Unicare Health SALSA 200 Скачать руководство пользователя страница 10

9

SALSA Mobile Standing Transfer Hoist Instruction & Safety Manual

T

 08 9351 7500              

E

 [email protected]              

W

 www.unicarehealth.com.au

General Lifting Procedure

The information supplied below is not intended to be construed as a training manual but as a general 

guide to lifting procedure only.

• 

The SALSA hoist utilises a special type of padded sling designed to fi t around the patients lower 

back .It utilises a restraint belt to help prevent the sling from slipping and riding up the patients 

back. the restraint belt is adjustable and fastens with either a buckle or a velcro fl ap around the 

chest area.

• 

Key hole buckles on the sling clip onto the studs located on both lift arms of the hoist.

• 

For detailed sling fi tting instructions refer to COMFORT STANDING SLING USER MANUAL.

• 

N.B. THIS SLING SHOULD ONLY BE USED WITH THE SALSA HOIST AND MAY NOT BE 

COMPATIBLE WITH OTHER PATIENT HOISTS.

• 

Manoeuvre the hoist around the patient, adjusting the legs to fi t around chair, wheel chair etc. If 

lifting from a bed ensure under bed clearance is suffi cient to manoeuvre legs under the bed.

• 

Lower the SALSA lift arms using the handset buttons until sling keyhole buckles can reach and 

easily engage the studs on the lift arms. to prevent possible injury ensure the lift arms do not come 

in contact with patients face or body.

• 

Place keyhole buckles onto the correct stud on each lift arm and pull fi rmly to engae and lock. A 

slight resistance should be felt as the buckle moves to the lock position.

• 

Use the handset to raise the hoist boom enough to take up the patients weight. At this point stop the 

lift .Check all sling attachments are secure and that the sling is positioned correctly. Check patient 

comfort .Lower and realign sling if necessary.

General Maintenance

To prolong the working life of the lifter and for trouble free operation it is recommended that periodic 

inspections should be performed routinely and as often as necessary. Periodic inspections should be 

performed by a person who is suitably qualifi ed and well acquainted with the design, use and care of 

patient lifting hoists. 

If inspection reveals that the safety of the hoist is jeopardised in any way the hoist should be IMMEDIATELY 

WITHDRAWN FROM SERVICE, tagged as such and the owner notifi ed.

Содержание SALSA 200

Страница 1: ...SALSA Mobile Standing Transfer Hoist Instruction Safety Manual Please read this manual before operation for maintenance instructions and safe usage The enabling power of applied knowledge...

Страница 2: ...u W www unicarehealth com au Contents Overview 2 Important Saftey Considerations 3 Assembly Instructions 5 Hoist Operation 6 Actuator 6 Charging 7 Charging Indicator Lights 7 Charging Do s and Don ts...

Страница 3: ...d to both home or institutional use The SALSA is an electric operated hoist with ergonomic features designed with the patient and carer in mind An ALLEGRO standing sling speci cally designed for the S...

Страница 4: ...ng task should be assessed planned by a trained user Safety Considerations Ensure all that all users read this guide before operating the hoist Do not operate the hoist without training in the safe op...

Страница 5: ...4 T 08 9351 7500 E info unicarehealth com au W www unicarehealth com au Lift Arms Actuator Knee Pad Leg Battery Pack Push Handle...

Страница 6: ...nut 3 Repeat process 2 for second leg 4 Attach leg adjuster tie rod ends to each leg and tighten each nylock nut 5 Attach lift actuator to lifting arm assembly by aligning actuator clevis with actuato...

Страница 7: ...arrows and symbolised legs indicating the direction of travel This function allows an unrestricted range of leg adjustment The handset is also tted with a battery indicator light This will ash when th...

Страница 8: ...from control box by pulling the handle on the pack towards you Use both hands to support the battery pack when removing or replacing it Clip the battery pack onto the charging unit ensuring it is seat...

Страница 9: ...ty The batteries are not the nickel cadmium type and must not be periodically fully discharged Battery life is greatly reduced by deep or complete discharging of the batteries Longer lifetime is obtai...

Страница 10: ...ance is suf cient to manoeuvre legs under the bed Lower the SALSA lift arms using the handset buttons until sling keyhole buckles can reach and easily engage the studs on the lift arms to prevent poss...

Страница 11: ...gue lubricate and or adjust as required NB leg pivot bushes incorporate a Te on coated pivot bush which requires minimal lubrication Check tightness of bolt in leg bushes Check linkages are secure in...

Страница 12: ...up No mains connection Internal fuse blown Battery chargers is defective Plug into mains Replace fuse Repair replace charger Actuator will not run and no relay click is heard from control box Control...

Страница 13: ...KG BASE LENGTH 1050mm EXTERNAL BASE WIDTH 655mm INTERNAL BASE WIDTH CLOSED 585mm INTERNAL BASE WIDTH OPEN 1035mm BASE WIDTH ADJ ELECTRIC UNDER BED CLEARANCE 125mm MIN HEIGHT OF LIFT ARM 825mm MAX HEIG...

Страница 14: ...the improper or unsafe use of the product No warranty claim shall apply where the product or any part thereof has been modi ed varied altered or damaged either accidentally or through improper or negl...

Страница 15: ...7500 E info unicarehealth com au W www unicarehealth com au Log Book Service Type Condition Report Date Inspection by Signature Action Taken Service Type Condition Report Date Inspection by Signature...

Страница 16: ...PO Box 82 Bentley WA 6982 T 08 9351 7500 F 08 9350 5299 info unicarehealth com au www unicarehealth com au Authorised Distributor...

Отзывы: