24
3.9.1 - EXHAUST THROUGH EXTERNAL WALL
One of the installation solutions which can be implemented is
that of positioning NOVAIREX near a perimeter wall of the home
so that flue gas is discharged directly outside. Here are some
guidelines from the standard UNI 7129 for this particular type
of configuration:
- Always provide an inspection valve which allows you to
perform efficient and periodical cleaning as well as draining
any condensation formed;
- The chimney must be strictly wind and rain proof;
- Appropriately insulate the flue gas exhaust pipe in the section
passing through the wall.
The flue gas exhaust pipe, if completely outside, should be made
in double wall stainless steel to guarantee both greater resistance
to atmospheric agents and a sufficient flue gas temperature.
Draught
limiter/adjuster
Soot container with
condensate drain
weatherproof ter-
minal.