Installation Instructions
KONm 18 - 24
3.7 - CONNECTION
Danger!
The gas connection must be carried out
only by a qualified installer who must re
-
spect and apply that foreseen by relevant
laws in force in the local prescriptions of
the supply company. Incorrect installation
can cause damage to persons, animals
and objects for which the manufacturer
cannot be held responsible.
If you smell gas:
a) Do not operate electric switches,
the telephone or any other object that
may cause sparks;
b) Immediately open doors and
windows to create air current
to purify the room;
c) Shut the gas cocks.
The mains pressure must be within 1 and 3
bar (in the event of greater pressure install
a pressure reducer).
M
FLOw
3/4’’
R
RETURN
3/4’’
G
GAS
3/4’’
C
HOT
1/2’’
F
COLD
1/2’’
Sc
BOILER DRAIN
S.cond CONDENSATION DRAIN
Rc
FILLING VALVE
Svs
SAFETY VALVE DRAIN
Provide a drain pipe with funnel and a
trap that lead to a suitable drain, in cor-
respondence of Svs.
This drainage must be controlled on
sight.
If this precaution is not taken, trigger
-
ing of the safety valve can cause dam-
age to persons, animals and objects,
for which the manufacturer cannot be
held responsible.
Condensation drain
The boiler, during the combustion process, pro-
duces condensation that, through pipe “A”, flows
into the trap.
The condensation that forms inside the boiler flows
into a suitable drain via pipe “B”.
Condensation outlet, pipe to be connected to
the drainage system
Danger!
Before commissioning the appliance:
- check that the trap is assembled
properly
- check that the condensation is
drained properly
If the appliance is used with an empty
condensation drain trap, there is an
intoxication hazard due to the release
of exhaust gasses.