20
3.6 - LUE GAS EXHAUST PIPE CONNECTION
FOR BOILERS wITH FORCED DRAUGHT)
C13x
C13
% Slope towards inlet = 3%
LT** (
TOTAL LENGTH or LA L Exhaust)
COAXIAL Ø60/100
DOUBLE Ø80
FROM [m]
TO [m]
FROM [m]
TO [m]
1
5,5
1 + 1
40
(20A+20S)
COAXIAL Ø80/125
DOUBLE Ø60
FROM [m]
TO [m]
FROM [m]
TO [m]
1
8
1 + 1
20
(10A+10S)
Distance between air
inlet pipe and flue gas
exhaust pipe: min 250
mm - max 500
Horizontal
exhaust and intake terminals directed
outside via coaxial or double pipes..
LT
%
Calculation to determine the lengths
of the exhaust configurations
CAUTION
LT**
total length is a reference value
for the dimensioning of the ducts of
A
(intake) and
S
(Exhaust).
Subtracting the values of
LT
repor-
ted, at values of bends* / terminals*
/ extensions* you get the value:
if > 0 = OK
POSSIBLE configuration
if < 0 = NO
WRONG configuration
Please note: these values relate to
exhausts/made by means of rigid
pipes and smooth original UNICAL.
C33x
C33
LT** (
TOTAL LENGTH or LA L Exhaust)
COAXIAL Ø60/100
DOUBLE Ø80
FROM [m]
TO [m]
FROM [m]
TO [m]
1
7
0,5 + 0,5
40
(20A+20S)
COAXIAL Ø80/125
DOUBLE Ø60
FROM [m]
TO [m]
FROM [m]
TO [m]
1
9
1 + 1
20
(10A+10S)
Vertical
exhaust and intake terminals directed
outside via coaxial or double pipes.
To connect the flue gas exhaust pipe, local and na
-
tional standards must be observed
In the event the boiler is replaced, ALwAYS re-
place the flue gas pipe as well.
The boiler is type approved for the exhaust configu
-
rations listed below:
ATTENTION
[m]
= equivalent meters
(*) Values in the
MT018
available on the website (technical info section)
(*) Values in the
MT018
available on the website.