Stella di Caffè
USER GUIDE
15
Steam settings
(level 1, 2, 3)
Allow you to set the pressure of steam boiler.
Steam Air & hot air settings
(level 1, 2, 3)
Allow you to set the Steam air or hot water control box settings:
•
the temperature at the level of the thermostatic probe of the milk
(only for a machine with Steam Air)
•
the steam time-delay
•
the volumes of hot water
Spot pressure of the
steam boiler.
Touch the
+
and
–
keys to set the desired value.
Setting range: 0.7 Bar to 1.4 Bar, default setting 1 Bar
9
Do not forget to confirm the setting in order to save the
parameters.
9
When you select a line to make a setting, the color of
the value turns pink.
9
Touch the
+
and
–
keys to set the desired value.
9
Do not forget to confirm the setting in order to save the
parameters.
Setting range:
•
Steam Air probe: 50°C to 90°C , default setting 62°C
•
Steam time: 0 sec to 99 sec, default setting 10 sec
•
Small water volume: 0 to
2000 ml
, default setting 150 ml
•
Large water volume: 0 to
2000 ml
, default setting 300 ml