background image

Stella di Caffè 

USER GUIDE

 

 

 

 

23

 

Level 1: Brewer Roaster 

1 Desk  Back

3 CODES

4 Level Choice

5 Enter  code N1

6 Enter  code N2

7 Enter  code N3

8 Confirmation

9 PARAMETERS 

10 Date & Time

11 lLanguage

12 Sound

13 Desktop 

Background

14 Lighting

15 Unit

16  MACHINE 

SETTINGS

17 Group  Settings

22 Self-time

Small doses

3 1 small cup

24  2 small cups

25  3 small cups

Large doses

26  1 large cup

27  2 large cups

28  3 large cups

33 MAINTENANCE

38 counter

39 CIM  Parameters

40  Info, id,  sn

43 Computer  Connection

44 UTILIZATION

45 Clearning Group

46 Coffee Counter

48 Softener

49 ECONOMICS

50 Stop  Group

51/52Programming 

Day/Night

Day/Night Instant

Direct access

 

The dotted lines represent the main menu. 

Содержание Stella di Caffe

Страница 1: ......

Страница 2: ...sion settings 13 Self time settings 14 STEAM SETTINGS 15 STEAM AIR HOT AIR SETTINGS 15 FAST SETTINGS 16 MISCELLANEOUS 17 PANEL CLEANING 18 DOSAMAT CONTROL BOX 19 CONTROL BOX 2 CUPS 19 CONTROL BOX 3 CU...

Страница 3: ...ce is correctly earthed The manufacturer shall not accept any liability for damage due to faulty earth Only a qualified technician is allowed to access the internal parts of the appliance for maintena...

Страница 4: ...Never turn the machine on with the USB key inserted into the side of the machine Warming up The machine begins the warming up process once the Control Parameters panel appears Take into account appro...

Страница 5: ...et parameters for the functions day night groups watchfulness stop group programming day night Maintenance allow you to use or set parameters for the functions component test error list event log cool...

Страница 6: ...previous menu Make all values equal Scroll up or down Confirmation after change of a parameter Increase one value Decrease one value Display the history list of error codes This icon only appears when...

Страница 7: ...horized by the level are no longer grayed out Note If the entered code is incorrect an error message appears Reenter the code After entering the code additional options are now available by re clickin...

Страница 8: ...to make a setting the color of the value turns pink 9 Do not forget to confirm the setting in order to save the parameters Touch the and keys to set the desired value 9 When you select a value to make...

Страница 9: ...able to read them Contact your distributor for more specific information View of the programmed and actual temperature of each group View of the steam and pump pressure View of the steam and pump pre...

Страница 10: ...d Setting the color of the keys Activation Deactivation of the scrolling of colors of the keys and headband at the same time Setting the speed of the scrolling of the colors of the headband and keys 0...

Страница 11: ...level 1 2 3 Allow you to set and view the temperature of the groups pre infusion self times and doses Temperature settings level 1 2 3 Allow you to set the temperature of each group Programmed temper...

Страница 12: ...n this case the two cup portafilter is set When the desired coffee dose is reached Press small or large doses stop the infusion by touching continue stop To obtain the same value for the other Deactiv...

Страница 13: ...fusion mode remains inactive To activate the Pre infusion both times must be greater than 0 T1 Time in seconds Electrovalve open Electrovalve closed T2 Ti Ti T1 T2 0 no pre infusion Time in seconds El...

Страница 14: ...cup 0 5 second 9 Do not forget to confirm the setting in order to save the parameters Go to the 2 cup setting Touch the and keys to set the desired value Setting range 0 to 10 sec default setting 2 c...

Страница 15: ...Touch the and keys to set the desired value Setting range 0 7 Bar to 1 4 Bar default setting 1 Bar 9 Do not forget to confirm the setting in order to save the parameters 9 When you select a line to ma...

Страница 16: ...infusion close T2 pre infusion pressure overture P1 pre infusion pressure close P2 Do not forget to activate the PROgramming mode Set the desired portafilter In this case the two cup portafilter is se...

Страница 17: ...Setting of the chronometers display in the screen of each group CHRONO OFF deactivated CHRONO ON Activated visible at the end of the cycle DYNAMIC CHRONO Activated visible during the cycle Setting do...

Страница 18: ...Press the icon in the form of a broom until the boxes display nC When the command boxes show nC all of the keys are deactivated Press the red cross for three seconds to deactivate the cleaning mode an...

Страница 19: ...ntinue a cycle in progress non dosed A short click at the end of the cycle allows you to display the infusion time for the cycle if the chronometer function was activated Note it is possible to switch...

Страница 20: ...bers 1 2 3 1 dose 2 doses 3 doses The key allows you to select small dose c or large dose C The continue stop key allows you to do the following stop a cycle in progress continue a cycle in progress n...

Страница 21: ...a cycle in progress continue a cycle in progress non dosed A short click at the end of the cycle also allows you to display the infusion time if the chronometer function was activated Note it is poss...

Страница 22: ...R GUIDE 22 Stella program flowchart Level 0 User 1 DESK BACK 3 CODES 4 Level choice 5 Enter code N1 6 Enter code N2 7 Enter code N3 8 Confirmation 44 UTILIZATION 45 Clean Group The dotted lines repres...

Страница 23: ...16 MACHINE SETTINGS 17 Group Settings 22 Self time Small doses 3 1 small cup 24 2 small cups 25 3 small cups Large doses 26 1 large cup 27 2 large cups 28 3 large cups 33 MAINTENANCE 38 counter 39 CIM...

Страница 24: ...Pre infusion 20 Pre inf electrovalve 21 pre inf pressure sensor 22 Self time Small doses 23 1 small cup 24 2 small cups 25 3 small cups Large doses 26 1 large cup 27 2 large cups 28 3 large cups 30 C...

Страница 25: ...7 Group settings 18 Self time Small doses 23 1 small cup 24 2 small cups 25 3 small cups Large doses 26 1 large cup 27 2 large cups 28 3 large cups 31 Hot water steam settings 32 Steam air 29 Fast set...

Страница 26: ...cup 23 2 small cups 24 3 small cups 25 Large doses 1 large cup 26 2 large cups 27 3 large cups 28 30 Chrono by group 31 Hot water steam settings 32 Steam Air 29 Fast settings 33 MAINTENANCE Component...

Страница 27: ...r each unit Filter holder gasket Insert the filter holder into the unit without tightening it Turn the unit on at the same time tightening and loosening alternately the filter holder in order to creat...

Страница 28: ...NZ9002 Rev 2 0 12 2011 www unic fr info unic fr Z I 4 Rue B P 425 06515 CARROS CEDEX 1 FRANCE T l 33 04 92 08 62 60 Fax 33 04 93 29 24 23...