2.5 Alignment and Mounting Suggestions
If a PTO pump shaft style is used, it is imperative that the pump and motor are properly aligned before operating. Misalignment
can lead to excessive wear and can cause the coupling to rupture. It can also create abnormal stresses on bearings and gears.
HYDRAULIC DRIVE PUMP WITH ALTERNATE RELIEF
VALVE COVER
PTO PUMP WITH VERTICAL PORTS
FLOW
FLOW
PTO PUMP WITH HORIZONTAL PORTS
FLOW
FLOW
HYDRAULIC DRIVE PUMP WITH HORIZONTAL PORTS
STATIONARY UNIT ON BASEPLATE
2.6 Clean the System Before Start-Up
Clean system of all debris before start-up. Any remaining particles larger than 0.002 in. (0.05 mm) can damage the pump if they
enter it. A filtering device installed before the pump inlet is highly recommended to insure safe and proper operation. Since such
a device will restrict the flow in to the pump, it is necessary to verify that the net positive suction head (NPSH) available is not
reduced below that required by the pump.