![Uni-Trend UTD2000E Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/uni-trend/utd2000e-series/utd2000e-series_manual_839099020.webp)
UNI-T
UTD2000E Series Osilloscope Programming Manual
and FFT is not applicable.
<value> presents CHANnel<n>
,
<n> take vaule as 1/2/3/4{CH1/ CH2/ CH3/ CH4}.
Return format:
Query return <n> take valu as 1/2/3/4/5/6/7/8/9.
For example:
:FUNCtion:SOUR1 CHAN1
choose channel 1 as source 1
:FUNCtion:SOUR1?
query return1
:FUNCtion:SOUR2 CHAN2
choose channel 2 as source 2
:FUNCtion:SOUR2?
query return 2
:FUNCtion:OPERation ADD
add source 1 and source 2
:FUNCtion:FFT:WINDow
Command format:
:FUNCtion:FFT:WINDow {RECTangular|HANNing|HAMMing|BMAN}
:FUNCtion:FFT:WINDow?
Functional description:
FFT windowing to intercept signal. RECT, HANN, HAMM, BMAN
is rectangular window,
Hanning window, Hamming window and Blacman window respectively.
Return format:
Query return {RECTangular|HANNing|HAMMing|BMAN}.
For example:
:FUNCtion:SOUR1 CHAN1
set channel 1 as source 1
:FUNC:FFT:WIND HAMM
windowing Hamming window
:FUNC:FFT:WIND?
query return HAMMing
:FUNCtion:FFT:VTYPe
Command format:
:FUNCtion:FFT:VTYPe {VRMS|DBRMS}
:FUNCtion:FFT:VTYPe?
Functional description:
Set unit of FFT vertical diection as dbrms or VRMS. dbrms presents root mean square of power;
VRMS presents root mean square of voltage.
Return format:
Query return VRMS, DBRMS
For example:
:FUNCtion:SOUR1 CHAN1 set channel 1 as source 1
:FUNC:FFT:VTYP VRMS
set unit of FFT vertical diection as root mean square of voltage
:FUNC:FFT:VTYP?
query return VRMS