UTL8500 Series User Manual
19
Figure 4-1-2-1 Setting Interface of CV Mode
Operation Steps:
1. In initial interface, select [Mode], and then press [CV] to enter the setting interface of
<Constant Voltage CV>.
2. Move the cursor to voltage setting by pulse knob, and press the Enter button
to
change the voltage value (the value changes from yellow to white) by keyboard or
pulse knob. Press the Enter button
again to confirm. At this time, the set voltage
value changes from white to yellow.
3. Other parameters can be modified in a similar way.
4. Press the ON button, the electronic load starts to load, and the indicator light below the
button lights up. If you need to stop the load, press the ON button again, and the
running indicator light goes out.
Figure 4-1-2-2 Relationship of Voltage and Current in CV Mode
4.1.3 Constant Resistance Test
In CR mode,
the electronic load is equivalent to a resistance; it changes the input current
as the voltage changes to maintain a constant resistance value.
Constant Voltage Mode