User’s Manual                                                                                                                                                           Series DC Electronic Load 

Instruments.uni-trend.com

                                                                                                                                                                                   

7

 / 

33

 

 

abnormal function. Please refer to the product manual for the rated value of the 

input / output port of this device.

 

Power fuse 

Please use power fuse of specified specification. If the fuse needs to be replaced, it 

must be replaced with the specified fuse by the maintenance personnel authorized 

by UNI-T.

   

Disassembly  and 
cleaning 

There are no components available to operators inside. Do not remove the 
protective cover.   

Maintenance must be carried out by qualified personnel.

 

Service 
environment 

This device should be used indoors in a clean and dry environment with ambient 
temperature from 0 

  to 40 

.   

Do not use this device in explosive, dusty or humid air.

 

Do not operate in 
humid 
environment 

Do not use this device in a humid environment to avoid the risk of internal short circuit 
or electric shock. 

Do not operate in 
flammable and 
explosive 
environment 

Do not use this device in a flammable and explosive environment to avoid product 
damage or personal injury. 

Caution

 

Abnormality 

If this device may be faulty, please contact the authorized maintenance personnel of 
UNI-T for testing. Any maintenance, adjustment or parts replacement must be done 
by the relevant personnel of UNI-T. 

Cooling 

Do not block the ventilation holes at the side and back of this device. 
Do not allow any external objects to enter this device via ventilation holes. 
Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides, 
front and back of this device. 

Safe 
transportation 

Please transport this device safely to prevent it from sliding, which may damage the 
buttons, knobs or interfaces on the instrument panel. 

Proper 
ventilation 

Poor ventilation will cause the device temperature to rise, thus causing damage to 
this device. Please keep proper ventilation during use, and regularly check the vents 
and fans. 

Keep  clean  and 
dry 

Please take actions to avoid dust or moisture in the air affecting the performance of 
this device. Please keep the product surface clean and dry. 

Note

 

Calibration

 

The recommended calibration period is one year. Calibration should only be carried 

out by qualified personnel.

 

 

Содержание UTL8200+ Series

Страница 1: ...User s Manual UTL8200 Series DC Electronic Load...

Страница 2: ...e customer must inform the defects within the applicable warranty period to UNI T and to perform appropriate arrangements for the warranty service The customer shall be responsible for packing and shi...

Страница 3: ...d and pending patents UNI T reserves the rights to any product specification and pricing changes UNI T reserves all rights Licensed software products are properties of Uni Trend and its subsidiaries o...

Страница 4: ...sers to pay attention to a certain operation process operation method or similar Product damage or loss of important data may occur if the rules in the Caution statement are not properly executed or o...

Страница 5: ...I circuit or sockets more than 20 meters away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and...

Страница 6: ...cord is conductive If the cord is damaged please replace it before using the instrument Instrument Grounding To avoid electric shock the grounding conductor must be connected to the ground This produ...

Страница 7: ...onment to avoid product damage or personal injury Caution Abnormality If this device may be faulty please contact the authorized maintenance personnel of UNI T for testing Any maintenance adjustment o...

Страница 8: ...st conditions and is convenient to connect seamlessly with automated production lines and automatic test systems ATS The electronic load is stable and widely used to meet various testing requirements...

Страница 9: ...Display Display the operating state of channel with load measurement parameter and operation mode 3 Key Select test mode CC CV CR CP and etc For the specified function 4 Channel input port Input load...

Страница 10: ...rol input state of the load ON OFF LOCK Lock key long press to unlock short press to lock 4 4 2 Quick Function Key In the specified interface key can be combined with Shift key to quickly execute the...

Страница 11: ...110V AC power socket 3 Fuse 4 Power Switch AC 220 110V Switch of AC voltage 5 RS232 External communication interface for remote control the electronic load 5 Inspection and Installment 5 1 Packing Lis...

Страница 12: ...10 V Frequency 50 60HZ Power Consumption 50W Fuse AC 220V input voltage 250V 0 25A AC 110V input voltage 250V 0 5A Factory supply three core power cable please make sure power cable of three phase so...

Страница 13: ...ents alcohol or gasoline to clean the instrument 6 Measurement 6 1 Power Up The correct self inspection of electronic load is as follows 1 Connecte the power cord corretly and make sure the 110V 220V...

Страница 14: ...hown in the following figure 6 2 2 Measurement Interface No Name Description 1 State and mode information Display the current state of on load channel remote control short circuit test and trigger fun...

Страница 15: ...Trigger mode Manual Ext Trig Trigger mode is manua external mode Waiting for trigger Trigger The current mode is waiting for trigger the mark will disappear when it generated Short circuit Short The l...

Страница 16: ...load consumes a fixed power and the current decreases as the voltage increases to maintain a constant power Dynamic Test Set two different current values the electronic load can step through the two v...

Страница 17: ...lluminated Press ON key again to stop the load and the indicator will be extinguished V I CV 0 Figure 7 1 2 Relation Schema of Voltage Current in CV Mode Operation steps 1 After the instrument is boot...

Страница 18: ...ge to maintain a constant power Select CP mode in mode interface press Enter key to enter CP mode and input power value Press ON key the electronic load will in load state and the indicator will be il...

Страница 19: ...parameter value of low scale Timing of low scale Set the load time of low scale High value Set the parameter value of high scale Timing of high scale Set the load time of high scale Rising Slop Set t...

Страница 20: ...figure Figure 7 1 5 3 Toggled Transient Operation Operation steps 1 After the instrument is boot up press CH key to select the channel yellow wireframe area is the selected channel and it will display...

Страница 21: ...0 groups of list files When set the list parameters set a group number at first Press Shift and then the Save key to save the setting Operation Mode Four operation mode Cont Trig ContEX TrigEX Cont Mo...

Страница 22: ...rotary knob to select the parameter to adjust press Enter key to change and press it again to save the setting Set list parameter group number step repeat times and mode press Enter key to enter the a...

Страница 23: ...uring the actual test user can view the battery voltage discharge current and discharged capacity at any time Operation steps 1 After the instrument is boot up press CH key to select the channel yello...

Страница 24: ...complete the setting 5 Press Mode key to enter selection interface select CC CV CP CR mode press Shift short to enter short circuit mode the short circuit mark Short will appear on the screen indicat...

Страница 25: ...protection event Polarity error If the positive and negaitive of input port is reverse connected it will trigger polarity error event Under voltage protection When the load is operating if it detects...

Страница 26: ...rsor to System Config press Enter key to enter System Config page this page includes the list setting as follows System Parameter Setting Description Language CHN Englishh Set the system language Knob...

Страница 27: ...same system configuration as shown in Figure 8 3 Figure 8 3 System Configuration Set Baud Rate Figure 8 4 Baud Rate Setting Setup Steps 1 Use rotary knob or direction key to move the cursor to baud r...

Страница 28: ...HIGH I Rise 0 01A uS 1A uS Rising speed of the current I Fall 0 01A uS 1A uS Falling speed of the current Short T 0 9999 9mS Set the protective detection time for short overcurrent I Limit 0 40A 20A 1...

Страница 29: ...al Flash for check Figure 8 6 UTL8211 List File Management Select one of the list file use combination key Shift ESC Delete to delete the file Select one of the list file press ON key to enter the fil...

Страница 30: ...erminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear to Sent 9 RI Ring Indicator 9 2 Communication Setting Communication setting is used to set the communication parameter...

Страница 31: ...0 150V 0 150V Input Current 0 40A 0 20A single group channel Input Power 400W 200W x 2 Minimum of Operating Voltage 2 0V at 40A 2 0V at 20A CV Constant Voltage Mode Range 0 150V 0 150V Resolution 1mV...

Страница 32: ...dance of Input Terminal 300K Fuse Specification 0 5A 110V 0 25A 220V Communication Interface RS232 Protocol SCPI Data Acquisition Software Power Requirements 110V 10 220V 10 Frequency 50 60Hz Size mm...

Страница 33: ...s proven to be defective within this period UNI T will repair or replace the product in accordance with the detailed provisions of the warranty To arrange for repair or acquire warranty form please co...

Отзывы: