UNI-T
UPO 3000E&UPO2000E Series Oscilloscope Programming Manual
:SBUS:USB:DATA:QUALifier
{EQUal|LESSthan|GREaterthan|NEQUal|LEQUal|GEQUal|
INRange|OUTRange}
:SBUS:USB:DATA:QUALifier?
Functional description:
Set trigger term of USB data pack.
Return format:
Query return{EQUal|LESSthan|GREaterthan|NEQUal|LEQUal|GEQUal|INRange|OUTRange}.
For example:
:SBUS:USB:DATA:QUALifier EQUal
set trigger term as EQUal
:SBUS:USB:DATA:QUALifier?
query return EQUal
:SBUS:USB:DATA:OFFSet
Command format:
:SBUS:USB:DATA:OFFSet <offset>
:SBUS:USB:DATA:OFFSet?
Functional description:
Set offset byte of USB data pack, <offset> is integer data, range 0~15.
Return format:
Query return offset of USB data pack.
For example:
:SBUS:USB:DATA:OFFSet 2
set offset byte as 2
:SBUS:USB:DATA:OFFSet?
query return 2
:SBUS:USB:DATA:LOW
Command format:
:SBUS:USB:DATA:LOW
<string>
:SBUS:USB:DATA:LOW?
Functional description:
Set low trigger data of USB data pack, parameter is character string of 0x format, data range
0x0~0xFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF.
Return format:
Query return character string of 0x format.
For example:
:SBUS:USB:DATA:LOW "0x5F"
set negative data of USB signal line as 0x5F
:SBUS:USB:DATA:LOW?
query return 0x5F