UNI-T
UPO 3000E&UPO2000E Series Oscilloscope Programming Manual
Query return character string of 0x format of bus data.
For example:
:SBUS:RS232:DATA "0x7F"
set RS232 bus data as 0x7F
:SBUS:RS232:DATA?
query return 0x7F
:SBUS:RS232:QUALifier
Command format:
:SBUS:RS232:QUALifier {BEGFrame | ERRFrame | ECCError | DATA}
:SBUS:RS232:QUALifier?
Functional description:
Set RS232 bus term.
Return format:
Query return{BEGFrame|ERRFrame|ECCError|DATA}.
For example:
:SBUS:RS232:QUALifier ERRF
set RS232 bus term as error frame
:SBUS:RS232:QUALifier?
query return ERRFrame
I2C
:SBUS:I2C:CLOCk:SOURce
Command format:
:SBUS:I2C:CLOCk:SOURce { CHANnel1 |
CHANnel2 |
CHANnel3 | CHANnel4 }
:SBUS:I2C:CLOCk:SOURce?
Functional description:
Set clock source of I2C bus.
Return format:
Query return{ CHANnel1 |
CHANnel2 |
CHANnel3 | CHANnel4 }.
For example:
:SBUS:I2C:CLOCk:SOURce CHANnel1
set channel 1 as I2C bus clock source
:SBUS:I2C:CLOCk:SOURce?
query return CHANnel1
:SBUS:I2C:DATA:SOURce
Command format:
:SBUS:I2C:DATA:SOURce { CHANnel1 |
CHANnel2 |
CHANnel3 | CHANnel4 }
:SBUS:I2C:DATA:SOURce?
Functional description: