21
MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
ERROR
CODE
Flashing LED
Lights
Description
Action Required
READY
(L)
READY
(H)
32
3 TIMES
2 TIMES
Micro Controller has been reset
due to power interruption or drop
in voltage during the recycling
operation.
Press “OFF” and then “ON” but-
tons to resume operation. Discon-
nect power at the source for about
30 seconds. Usually nothing is
wrong with the unit.
33
3 TIMES
3 TIMES
a) Recycling did not fi nish in 6
hours due to power interruption or
excessive debris in Liner Bag
a) Clean Distillation Tank following
Operating Procedure 7, replace
Liner Bag, following Operating
Procedure 9,
b) Temperature Set Point is too
low for the solvent.
b) increase Temperature Set Point
following Operating Procedure 4
and recycle with virgin solvent
c) Boiling point of solvent is
above maximim set point.
c) Solvent cannot be recycled.