10
MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
Revision 2019-07
b) For models with the Solvent Transfer System (EP2 Models):
• Open the Transfer Valve by turning the handle counter-clockwise 90°.
• Turn the Filling Timer knob clockwise fully. Dirty solvent will fl ow from the Transfer Port into the Liner
Bag and stop when the timer runs out.
• Close the Transfer Valve by turning the handle clockwise 90°.
• Close the tank Lid, lock down the Lid Clamp and close the safety Cover.
Transfer Valve
Filling Timer
Transfer Timer
Transfer Port
3) Position Solvent Receiving Pail
a) For models without the Solvent Transfer System
Open the Door and position a Solvent Receiving Pail (not provided) with a minimum size of
5 US Gal (20 L) inside the cabinet. Insert the Solvent Outlet Tube (short and curved) into the top opening
of the pail. The Solvent Outlet Tube must extend below the rim of the pail to prevent solvent spillage. If
the pail is metal, connect the alligator clamp of the Ground wire to the rim of the pail. Close the door.
b) For models with the Solvent Transfer System (EP2 Models):
Open the Door. A special, connected, plastic Solvent Receiving Pail is provided. Check to make sure that:
• the Solvent Outlet Tube is inserted into the hole in the top of the pail
• the Cap with the Pick Up Tube is tightly attached to the pail
• the Grounding Clamp (alligator type) is attched to the metal Pick Up Tube hose fi tting.
4) Change temperature set point, as required. If the Temperature Set Point is satisfactory, skip
this section.
Conditions to consider before starting Setup:
Minimize Temperature Set Point
After recycling there will be a small amount of solvent, about 1/8 US gal (500 ml), remaining in the distil-
lation tank due to condensation. Select the lowest Temperature Set Point that recycles the solvent to this
level.
Estimate Boiling Point
Add
45°C
(113°F)
to
the
boiling
point
of
the
pure
solvent
as
shown
on
the
MSDS
(Material
Safety
Data
Sheet)
or
another
reliable
source.
Recycle more often
The boiling point of the waste solvent mixture increases as it gets dirtier. To reduce the boiling point,
recycle more often.
The display for the Control Panel is located at the top right corner of the base cabinet.
The LEDs for READY(L) and READY(H) on the control panel indicate the Temperature Set Point.