2. BEFORE USE
For each start up all substantial parts of the
HydroPower RO XXL
must be checked by taking them in
consideration like for example: all the cleaning equipment is still fixed firmly, check hoses and electric wiring on
damages. Persuade yourself of the safety regulations from previous chapter.
Before starting, check the
HydroPower DI
on cracks. Be sure the cover is in locked position.
Keep discharge line open and hold yellow lever down to remove trapped air from system.
For use only with drinking water.
2.1. Accomplish water supply and water outlet
2.1.1. Accomplish water supply
The water supply pipe can be connected (towards circumstances) on their own water supplies
(under pressure) or on a drinking water supply with a water barge. When the machine is connected to the
drinking water supply, the existing regulations about that must be observed ( EN 1717 ).
Water supply under pressure:
Maximum hose length 50 m (160 ft), minimum hose diameter (inside) 12.7 mm (1/2”).
Check the water pressure using a water meter.
2.1.2. Concentrate water
Check that all water outlets have been correctly connected.
Take the necessary measurements so that the water concentrate is suitable enough to drain.
2.1.3. Anti- legionella bacterium measure
If the machine has stood still some time, the water in the machine must be drained above an evacuation.
Stationary water that becomes hot (between 20 - 55°C) can cause the legionella bacterium.
• Clean therefore piping and tanks on a yearly base.
• Remove possible sediment.
• Rinse periodically.