background image

T

www.ungerglobal.com

6

HydroPower® RO XXL

General Warnings

1. SAFETY - GENERAL WARNINGS

General:

Please observe the applicable rules and regulations, as well as the effective accident prevention regulations. 

UNGER is not liable for any occurring water damage. Make sure that the area of application has sufficient water 

drainage. Close feed valve in case of prolonged shut-down times (e.g. weekends).

The 

HydroPower RO XXL

 can be exclusively used by trained and qualified persons who have been instructed in 

the service of it and explicitly with the service of it have been charged. 

For this reason a complete knowledge of this guide is necessary to avoid damage to yourself, third parties,  

objects or to the machine self. The 

HydroPower RO XXL

 is not suitable for use by children or young people! Not 

instructed personnel or persons with limited psychical, physical skills may not use the machine. 

If the machine is used by other persons than you must as an owner inform the user of the safety regulations. The 

use of the 

HydroPower RO XXL

 falls under the applying national provisions. Beside the instructions for use and 

in the country where the machine is used applying binding regulations concerning accidents prevention, also the 

recognised technical rules for safely and judicious work must be observed. 

Each working method which can be dangerous for safety matters must be avoided.

Protect the trailer from standing in direct sunlight. The black cover and the metal plates become hot and could 

lead to injuries. The longevity of all components like membrane, resin filter and even pure water is longer at 

normal temperatures.

Hoses:

Hoses, fittings and joints are important for the safety of the machine.

Use only by the manufacturer approved parts! Do not use the hose as a draft cable. 

Look out for tripping hazard when the hose is unrolled from the reel.

Please note:

 block the hose reel with the locking handle and hook, couple the left/right flow reel hoses to the 

RO- connections at transporting the trailer (so the hoses are locked & could not unroll!)

Uncouple the hoses again (after transport) from the RO- connections when using the reels of the cleaner! 

Spraying:

The water hose may not be aimed on yourself, persons, animals, installations under electric tension or at the 

machine itself. 

Never spray electric installations with water: danger for persons, short circuit danger.

Carry safety clothing, safety optical device, if necessary! 

During the use keep all protective coverings and doors (cap) of the machine closed!

Any surface that becomes wet must be identified with appropriate signage to direct pedestrians and workers 

away from work area. During wintertime, it is important to avoid water pooling, which could freeze, creating a 

dangerous slip hazard. Do not clean sensitive parts with the jet. 

Never spray water from an unstable duty station/place (ladder, small boat, wharf...). 

Spray equipment:

Stop the machine, if spraying equipment need to be exchanged. Fix the spray equipment correctly. 

Take the necessary safety precautions when spraying!

Machine:

Never take the 

HydroPower RO XXL

 in use without water. Even a brief lack of water can lead to  

damages! When the machine is connected to the drinking water supply, the existing regulations about that must 

be observed (EN 1717). The machine must stand on a stable horizontal base & with the trailer in braked position! 

Working at artificial light: if daylight offers not sufficient visibility during the use, the use of adapted  

impermeable lighting armature(s) stretches to recommendation. In spaces provide with standard lighting these 

must remain on wide distance of the water jet. Never work outdoors during a storm or bad weather. 

Fixed adjustments of the machine may not be modified under no circumstances. 

The 

nLite® HydroPower RO XXL

 has been made in running order and tested by UNGER according the safety 

standards. When the machine is in use these can never be left behind unattended. 

Do not spray materials containing asbestos or other health-hazardous substances.

Water outlet:

Take care for a sound and smooth water outlet of the concentrate.

Traffic:

Protect piping and cables with protective boards/plates when they are lying on a roadway.

Содержание HydroPower RO XXL

Страница 1: ...T OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG MODE D EMPLOI ISTRUZIONI PER L USO INSTRUCCIONES DE MANEJO BEDIENINGSHANDLEIDING 1 Fully Integrated Trailer System with RO Filter tank for 650l pure water...

Страница 2: ...osmosis membrane RO 18 6 2 5 Adding membrane preservative medium 18 6 2 6 Carbon water filter 18 6 2 7 Maintenance of the trailer 18 6 2 8 Maintenance at expense of technicians 19 6 3 Description dail...

Страница 3: ...rrors Wrong usage of loose resin Overfill expansion of resin Parts of the system are opened incorrectly Replacing spare parts that are not included in the official Unger spare parts price list Perform...

Страница 4: ...h electric components of the machine The areas on the machine marked with this symbol containing electric components and can never be opened or adapted by unauthorized person Toxic substances When the...

Страница 5: ...rties Guarantee expires At change of owner At modifications repairing by a not recognised UNGER repairer Liability UNGER Germany GmbH as a manufacturer cannot become responsible for personal lesion da...

Страница 6: ...ting the trailer so the hoses are locked could not unroll Uncouple the hoses again after transport from the RO connections when using the reels of the cleaner Spraying The water hose may not be aimed...

Страница 7: ...return valve to prevent water flowing back into drink water line Trailer We recommend to transport the trailer without water a filled water tank could affect the riding behavior of the trailer Do not...

Страница 8: ...d towards circumstances on their own water supplies under pressure or on a drinking water supply with a water barge When the machine is connected to the drinking water supply the existing regulations...

Страница 9: ...trieve at the end of the manual 3 2 Visual perception HOSE REELS WATER TANK REVERSE OSMOSIS FILTER RO CARBON PRE FILTER ION EXCHANGE RESIN FILTER DI HydroPower DI DI24T CONTROL BOX nLite HydroPower DI...

Страница 10: ...d materials are rejected by the membrane and carried away in the concentrate water stream The purified water contains only a fraction of these materials with TDS total dissolved solids a measure of th...

Страница 11: ...our pressure causing cavitation degassing vapour lock and a loss in performance Inlet pressure must not exceed max 2 1 bar 30 psi Cover cap The cover cap could be opened closed easily by means of 1 lo...

Страница 12: ...wrate for rinsing the surface Push the R button on the remote control RIN appears in the control box display and the diaphragm pump delivers more flow boost The rinsing value is by default always 30 h...

Страница 13: ...CLARIFICATION bAt This message will start to flash when the battery tension is to low If battery is below 10 5V the pump will be disabled to protect the battery unless low battery cutoff is disabled C...

Страница 14: ...ions for potential possibilities through coupling Caution lock the tow ball coupling correctly safely to your riding vehicle in case you want to use a removable coupling Pay attention for possible loo...

Страница 15: ...e cable Extend support arm Technical check Mirror adjustment and clear visual from the car Check the cable guide of the trailer Perform lighting test Check ball joint lubrication Perform air pressure...

Страница 16: ...pressure of the tires ca 4 bar and profile depth Couple the trailer and make sure that the shaft is connected firmly By pulling the shaft powerful up you can check if the coupling is put on firmly Tu...

Страница 17: ...all sliding or jointed parts of the overrun device Check on possible wear of the wheel brakes bearings brake lining yearly 6 2 3 Ion exchange resin filter DI changing resin bags Instructions Shut off...

Страница 18: ...no good filter results For this reason a special care agent must be filled in order to avoid this blocking 1 Disconnect the water supply if connected 2 Connect the concentrate hose so that excess wate...

Страница 19: ...bolts of the trailer and if necessary fasten the wheel bolts Follow the good torque moments see also technical data 8 4 Repeat this always when a wheel is loosened for example if a tyre is changed tig...

Страница 20: ...aks external damages and hair cracks If damaged or at leaks these must be immediately replaced 6 3 5 Electrical parts Check visible electric wiring and components on external visible damages If damage...

Страница 21: ...chanism defective Push the locking pin to open and replace if necessary Insufficient braking of trailer Excessive friction losses or corrosion on the drawbar Damage caused by impact during manoeuvring...

Страница 22: ...pump inlet outlet vlaves Leaks from pump head or switch For loose screws at switch or pump head Switch diagraphm ruptured or pinched For punctured diapgragm if fluid is present at bottom drain holes...

Страница 23: ...water temperature 4 C Maximum water temperature See technical data Sufficient water supply at drinking water quality Directive 98 83 EG Depending on the composition of the raw water the treated water...

Страница 24: ...11 Nm 25 Nm 36 Nm 43 Nm M 10 17 Nm 22 Nm 49 Nm 72 Nm 84 Nm M 12 29 Nm 39 Nm 85 Nm 125 Nm 145 Nm M 14 133 Nm 195 Nm 229 Nm M 16 206 Nm 302 Nm 354 Nm M 18 71 Nm 95 Nm 210 Nm 310 Nm 365 Nm M 20 138 Nm 18...

Страница 25: ...V DC 210A Gel battery OPERATING PRESSURE max 10 bar 150 psi WATER FLOW RATE max 250l h MAX WATER IN TEMPERATURE 4 C WATER OUT TEMPERATURE 30 C NOISE LEVEL 75 dB DIMENSIONS LxWxH 3500x1750x1600 mm WEIG...

Страница 26: ...3 28 83 188 4 8 4 PLACES 2 25 57 9 48 241 3 56 90 3 18 81 4 00 102 2 12 54 4 09 104 FILE 8030 813 239 REVISED 11 02 ISSUED 8 13 98 PumpAgents com buy pumps and parts online PumpAgents com Click here...

Страница 27: ...S THIS GRAPH IS FOR USE AS A DESIGN GUIDE IT IS BASED ON RUNNING CONTINUOUSLY WITH AN AMBIENT TEMPERATURE OF 75o F IN STILL AIR THE THERMAL BREAKER WILL OPEN WHEN THE CASE TEMPERATURE REACHES 205 o F...

Страница 28: ...hen be removed as ecologically sound as possible The possibilities those are open Exchange on a new machine Hand in at an waste treatment company Outside the E U you contact best the local government...

Страница 29: ...in charger in the vehicle or machinery The charger can be with fixed connection to the battery or with conventional connectors Position the charger in such a way that the air supply will not be obstr...

Страница 30: ...in Cable 1 6M full length 3 x 1 0 mm2 Protection IP 65 General Protected against wrong polarity and short circuit CE and Euronorms In accordance with the Low Voltage Directive 72 245 EEC and 2004 104...

Страница 31: ...www ungerglobal com 31 HydroPower RO XXL Notes ENGLISH...

Страница 32: ...rglobal com Unger UK Ltd F1 Deansgate 62 70 Tettenhall Road Wolverhampton WV1 4TH UNITED KINGDOM Fon 44 0 1902 306 633 Fax 44 0 1902 306 644 ungeruk ungerglobal com Unger Enterprises LLC 425 Asylum St...