4. OPERATION CONTROL BOX

4.1. Control box - Overview

The UNGER Control Unit provides a simple operation of the two water 

pumps, which deliver the pure water and the RO filling unit, which fills 

the tank with purified water. 

LEFT FLOW = Controls the pump for the left hose reel.

RIGHT FLOW = Controls the pump for the right hose reel.

RO FILLING = Controls the filling of the tank with purified water.

With the remote controls the left and right pump can be controlled from 

a distance and you can switch between “wash” and “rinse” mode.

The remote control works on a distance of max. 100m in open area. If 

buildings or plants are between the operator and the trailer, the reach 

can be reduced.

4.2. Operating the left/right flow

1.  Switch on the desired pump (left/right) by pressing the UP-button 

.

2.  Adjust the desired water output on the control box using the UP/DOWN-buttons 

.

•  The controller also provides an indication of flow rate (range: 0-99).

•  The difference between wash and rinse mode is set by default at 

30

. This value can be changed  

(see below “Rinse Speed Mode”)

•  Default set speed:  

   

30 (washing) = 60 (rinsing)

•  Example-possible wash speed adjustment :  

40 (washing) = 70 (rinsing) 

3.  If you press ENTER 

 again, you see the battery voltage. Example: 

BAT

,

 12.4 

Note:

 At 14,0 ithe battery is fully charged, at 10,5 it shuts off.

4.  When you  press ENTER 

 once more, you are back to the flow rate 

FLO

5.  To switch off the controller, press and hold ENTER 

.

4.2.1 Remote Control

It’s also possible to use the remote control to switch the related pump (left or right) on/off or to change  

between wash and rinse mode. The remote control allows you to change the flow from the place where you  

are working (max. 100m in open areas).

WASH MODE 

(to select a normal flowrate for standard cleaning):

•  Push the W 

 button on the remote control

RINSE MODE

 (to select a higher flowrate for rinsing the surface):

•  Push the R 

 button on the remote control.

•  ‘

RIN

’ appears in the control box display and the diaphragm pump delivers more flow boost.  

The rinsing value is by default always 30 higher than the wash value, but max. 99.  

(or according the set value in Rinse Speed Mode).

Please also note the channel 

of each control for the case you 

lose it. Example here: „Ch. 01“

Remote Control

On the backside of the remote 

control you can read if it is for 

the left or right hose reel.

Control Unit

Calibration Mode:

In calibration mode it is defined when the system shuts off at “dead end” situations (e.g. interrupted waterflow, air in the line etc.). 

Pay atten-

tion:

 The default setting of 

79  

should 

NOT

 be changed. A higher value could damage the system as it shuts off possibly to late. A lower value 

could cause that the system shuts off too early.

• 

When pushing both UP&DOWN buttons 

, you are entering in the 

CAL

 mode (calibration) - if that happened accidentally go 

back by pushing the ENTER button 

 button!

• 

This is a WATER PUMP controller: it will not work with air in the system. Air could cause false dead-end detection.

• 

Always prime your system before starting work.

• 

Repeated false dead-end detection (

dE

) indicates that the 

CAL

 value should be increased (less sensitive). But don’t set the  

CAL 

value too high as this could cause damage to the pump.

• 

There is as well an “AutoCalibration” function. Press UP+ENTER button 

 + 

 to enter the 

CAL

 mode, press DOWN 

 to start 

the “AutoCal”-mode (

AUt

). After some seconds the calibration value will be displayed and has to be confirmed with ENTER 

Rinse Speed Mode:

The rinse water flow is always in same relation higher than wash flow. Default setting value: 

30

• 

If you

 

push both UP&DOWN buttons 

 longer, you are entering the setting mode for the rinse speed.

• 

You can change this value with the UP/DOWN buttons 

. The entered number is added to the washing speed when you activate 

rinsing. (Example: if you change value to 50: if wash is 40 then rinse is 90)

• 

Return to previous mode with the ENTER button 

• 

SET

’ is displayed now on the display to confirm the new value.

Содержание HydroPower RO XXL

Страница 1: ...T OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG MODE D EMPLOI ISTRUZIONI PER L USO INSTRUCCIONES DE MANEJO BEDIENINGSHANDLEIDING 1 Fully Integrated Trailer System with RO Filter tank for 650l pure water...

Страница 2: ...osmosis membrane RO 18 6 2 5 Adding membrane preservative medium 18 6 2 6 Carbon water filter 18 6 2 7 Maintenance of the trailer 18 6 2 8 Maintenance at expense of technicians 19 6 3 Description dail...

Страница 3: ...rrors Wrong usage of loose resin Overfill expansion of resin Parts of the system are opened incorrectly Replacing spare parts that are not included in the official Unger spare parts price list Perform...

Страница 4: ...h electric components of the machine The areas on the machine marked with this symbol containing electric components and can never be opened or adapted by unauthorized person Toxic substances When the...

Страница 5: ...rties Guarantee expires At change of owner At modifications repairing by a not recognised UNGER repairer Liability UNGER Germany GmbH as a manufacturer cannot become responsible for personal lesion da...

Страница 6: ...ting the trailer so the hoses are locked could not unroll Uncouple the hoses again after transport from the RO connections when using the reels of the cleaner Spraying The water hose may not be aimed...

Страница 7: ...return valve to prevent water flowing back into drink water line Trailer We recommend to transport the trailer without water a filled water tank could affect the riding behavior of the trailer Do not...

Страница 8: ...d towards circumstances on their own water supplies under pressure or on a drinking water supply with a water barge When the machine is connected to the drinking water supply the existing regulations...

Страница 9: ...trieve at the end of the manual 3 2 Visual perception HOSE REELS WATER TANK REVERSE OSMOSIS FILTER RO CARBON PRE FILTER ION EXCHANGE RESIN FILTER DI HydroPower DI DI24T CONTROL BOX nLite HydroPower DI...

Страница 10: ...d materials are rejected by the membrane and carried away in the concentrate water stream The purified water contains only a fraction of these materials with TDS total dissolved solids a measure of th...

Страница 11: ...our pressure causing cavitation degassing vapour lock and a loss in performance Inlet pressure must not exceed max 2 1 bar 30 psi Cover cap The cover cap could be opened closed easily by means of 1 lo...

Страница 12: ...wrate for rinsing the surface Push the R button on the remote control RIN appears in the control box display and the diaphragm pump delivers more flow boost The rinsing value is by default always 30 h...

Страница 13: ...CLARIFICATION bAt This message will start to flash when the battery tension is to low If battery is below 10 5V the pump will be disabled to protect the battery unless low battery cutoff is disabled C...

Страница 14: ...ions for potential possibilities through coupling Caution lock the tow ball coupling correctly safely to your riding vehicle in case you want to use a removable coupling Pay attention for possible loo...

Страница 15: ...e cable Extend support arm Technical check Mirror adjustment and clear visual from the car Check the cable guide of the trailer Perform lighting test Check ball joint lubrication Perform air pressure...

Страница 16: ...pressure of the tires ca 4 bar and profile depth Couple the trailer and make sure that the shaft is connected firmly By pulling the shaft powerful up you can check if the coupling is put on firmly Tu...

Страница 17: ...all sliding or jointed parts of the overrun device Check on possible wear of the wheel brakes bearings brake lining yearly 6 2 3 Ion exchange resin filter DI changing resin bags Instructions Shut off...

Страница 18: ...no good filter results For this reason a special care agent must be filled in order to avoid this blocking 1 Disconnect the water supply if connected 2 Connect the concentrate hose so that excess wate...

Страница 19: ...bolts of the trailer and if necessary fasten the wheel bolts Follow the good torque moments see also technical data 8 4 Repeat this always when a wheel is loosened for example if a tyre is changed tig...

Страница 20: ...aks external damages and hair cracks If damaged or at leaks these must be immediately replaced 6 3 5 Electrical parts Check visible electric wiring and components on external visible damages If damage...

Страница 21: ...chanism defective Push the locking pin to open and replace if necessary Insufficient braking of trailer Excessive friction losses or corrosion on the drawbar Damage caused by impact during manoeuvring...

Страница 22: ...pump inlet outlet vlaves Leaks from pump head or switch For loose screws at switch or pump head Switch diagraphm ruptured or pinched For punctured diapgragm if fluid is present at bottom drain holes...

Страница 23: ...water temperature 4 C Maximum water temperature See technical data Sufficient water supply at drinking water quality Directive 98 83 EG Depending on the composition of the raw water the treated water...

Страница 24: ...11 Nm 25 Nm 36 Nm 43 Nm M 10 17 Nm 22 Nm 49 Nm 72 Nm 84 Nm M 12 29 Nm 39 Nm 85 Nm 125 Nm 145 Nm M 14 133 Nm 195 Nm 229 Nm M 16 206 Nm 302 Nm 354 Nm M 18 71 Nm 95 Nm 210 Nm 310 Nm 365 Nm M 20 138 Nm 18...

Страница 25: ...V DC 210A Gel battery OPERATING PRESSURE max 10 bar 150 psi WATER FLOW RATE max 250l h MAX WATER IN TEMPERATURE 4 C WATER OUT TEMPERATURE 30 C NOISE LEVEL 75 dB DIMENSIONS LxWxH 3500x1750x1600 mm WEIG...

Страница 26: ...3 28 83 188 4 8 4 PLACES 2 25 57 9 48 241 3 56 90 3 18 81 4 00 102 2 12 54 4 09 104 FILE 8030 813 239 REVISED 11 02 ISSUED 8 13 98 PumpAgents com buy pumps and parts online PumpAgents com Click here...

Страница 27: ...S THIS GRAPH IS FOR USE AS A DESIGN GUIDE IT IS BASED ON RUNNING CONTINUOUSLY WITH AN AMBIENT TEMPERATURE OF 75o F IN STILL AIR THE THERMAL BREAKER WILL OPEN WHEN THE CASE TEMPERATURE REACHES 205 o F...

Страница 28: ...hen be removed as ecologically sound as possible The possibilities those are open Exchange on a new machine Hand in at an waste treatment company Outside the E U you contact best the local government...

Страница 29: ...in charger in the vehicle or machinery The charger can be with fixed connection to the battery or with conventional connectors Position the charger in such a way that the air supply will not be obstr...

Страница 30: ...in Cable 1 6M full length 3 x 1 0 mm2 Protection IP 65 General Protected against wrong polarity and short circuit CE and Euronorms In accordance with the Low Voltage Directive 72 245 EEC and 2004 104...

Страница 31: ...www ungerglobal com 31 HydroPower RO XXL Notes ENGLISH...

Страница 32: ...rglobal com Unger UK Ltd F1 Deansgate 62 70 Tettenhall Road Wolverhampton WV1 4TH UNITED KINGDOM Fon 44 0 1902 306 633 Fax 44 0 1902 306 644 ungeruk ungerglobal com Unger Enterprises LLC 425 Asylum St...

Отзывы: