background image

T

www.ungerglobal.com

2

HydroPower® RO XXL

Table of contents

TABLE OF CONTENT

Introduction

 .................................................................................3

Copyright UNGER GmbH

 .............................................................3

Marking through attention symbols

 ..........................................4

Guarantee

 ....................................................................................5

1. Safety - General warnings

 ......................................................6

2. Before bring in use

 ..................................................................8

2.1. Accomplish water supply and water outlet ...................8

2.1.1. Accomplish water supply .....................................8

2.1.2. Carry away water .................................................8

2.1.3. Anti- legionella bacterium measure ....................8

3. Operation

 .................................................................................9

3.1. General ...........................................................................9

3.2. Visual perception..........................................................91

3.3. Component review .......................................................10

4. Operation Control Box

 ..........................................................12

4.1. Control box - general info ............................................12

4.2. Operating left/right flow ..............................................12

4.3. Operating RO- system ..................................................13

4.4. Alarm/display messages .............................................13

4.5. Trailer ...........................................................................14

5. Turn off

 ..................................................................................16

5.1. Spray equipment ..........................................................16

5.2. Cleaner .........................................................................16

5.3. Water outlet ..................................................................16

5.4. Put away cleaner ..........................................................16

5.5. Transport ......................................................................16

5.5.1. General ...............................................................16

5.5.2. Storage at freezing temperatures .....................16

6. Service

 ...................................................................................17

6.1. General .........................................................................17

6.2. Maintenance diagram ..................................................17

6.2.1 General ................................................................17

6.2.2. Periodic maintenance ........................................17

6.2.3. Ion exchange resin filter (DI) -  

           changing resin bag(s) ........................................18

6.2.4. Changing osmosis membrane (RO) ...................18

6.2.5. Adding membrane preservative medium ..........18

6.2.6. Carbon water filter .............................................18

6.2.7. Maintenance of the trailer..................................18

6.2.8. Maintenance at expense of technicians .............19

6.3 Description daily control ...............................................20

6.3.1. Trailer .................................................................20

6.3.2. manometer ...........................................20

6.3.3. Machine parts ....................................................20

6.3.4. Spray equipment ................................................20

6.3.5. Electrical parts ...................................................20

6.3.6. Water tank ..........................................................20

6.3.7. Ion exchange resin filter ....................................20

6.3.8. Osmosis filter membrane ..................................20

7. Malfunction table

 ..................................................................21

7.1. Malfunctioning table ....................................................21

7.2. Troubleshooting diaphragm pump ..............................22

8. Technical data

 ........................................................................23

8.1. General .........................................................................23

8.1.1. Machine statement ............................................23

8.2. General data .................................................................23

8.3. Accessories ..................................................................23

8.4. Technical data trailer ...................................................24

Technical Data Overview .....................................................25

Technical Data Diaphragm pump .......................................26

9. After care

 ...............................................................................28

9.1. Storing the cleaner ......................................................28

9.2. No - activity during long period ...................................28

9.3. Remove installation environment friendly ..................28

10. Battery Charger

 ..................................................................29

10.1. Before charging ..........................................................29

10.2. General .......................................................................29

10.3. Installation .................................................................29

10.4. Function ......................................................................29

10.5. Trouble shooting and service .....................................29

10.6. Charging Algorithms ..................................................30

10.7. Technical Data ............................................................30

Read this original instructions manual attentively before operating the Pure Water filter sys-

tem. Take all safety instructions in mind!

Содержание HydroPower RO XXL

Страница 1: ...T OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG MODE D EMPLOI ISTRUZIONI PER L USO INSTRUCCIONES DE MANEJO BEDIENINGSHANDLEIDING 1 Fully Integrated Trailer System with RO Filter tank for 650l pure water...

Страница 2: ...osmosis membrane RO 18 6 2 5 Adding membrane preservative medium 18 6 2 6 Carbon water filter 18 6 2 7 Maintenance of the trailer 18 6 2 8 Maintenance at expense of technicians 19 6 3 Description dail...

Страница 3: ...rrors Wrong usage of loose resin Overfill expansion of resin Parts of the system are opened incorrectly Replacing spare parts that are not included in the official Unger spare parts price list Perform...

Страница 4: ...h electric components of the machine The areas on the machine marked with this symbol containing electric components and can never be opened or adapted by unauthorized person Toxic substances When the...

Страница 5: ...rties Guarantee expires At change of owner At modifications repairing by a not recognised UNGER repairer Liability UNGER Germany GmbH as a manufacturer cannot become responsible for personal lesion da...

Страница 6: ...ting the trailer so the hoses are locked could not unroll Uncouple the hoses again after transport from the RO connections when using the reels of the cleaner Spraying The water hose may not be aimed...

Страница 7: ...return valve to prevent water flowing back into drink water line Trailer We recommend to transport the trailer without water a filled water tank could affect the riding behavior of the trailer Do not...

Страница 8: ...d towards circumstances on their own water supplies under pressure or on a drinking water supply with a water barge When the machine is connected to the drinking water supply the existing regulations...

Страница 9: ...trieve at the end of the manual 3 2 Visual perception HOSE REELS WATER TANK REVERSE OSMOSIS FILTER RO CARBON PRE FILTER ION EXCHANGE RESIN FILTER DI HydroPower DI DI24T CONTROL BOX nLite HydroPower DI...

Страница 10: ...d materials are rejected by the membrane and carried away in the concentrate water stream The purified water contains only a fraction of these materials with TDS total dissolved solids a measure of th...

Страница 11: ...our pressure causing cavitation degassing vapour lock and a loss in performance Inlet pressure must not exceed max 2 1 bar 30 psi Cover cap The cover cap could be opened closed easily by means of 1 lo...

Страница 12: ...wrate for rinsing the surface Push the R button on the remote control RIN appears in the control box display and the diaphragm pump delivers more flow boost The rinsing value is by default always 30 h...

Страница 13: ...CLARIFICATION bAt This message will start to flash when the battery tension is to low If battery is below 10 5V the pump will be disabled to protect the battery unless low battery cutoff is disabled C...

Страница 14: ...ions for potential possibilities through coupling Caution lock the tow ball coupling correctly safely to your riding vehicle in case you want to use a removable coupling Pay attention for possible loo...

Страница 15: ...e cable Extend support arm Technical check Mirror adjustment and clear visual from the car Check the cable guide of the trailer Perform lighting test Check ball joint lubrication Perform air pressure...

Страница 16: ...pressure of the tires ca 4 bar and profile depth Couple the trailer and make sure that the shaft is connected firmly By pulling the shaft powerful up you can check if the coupling is put on firmly Tu...

Страница 17: ...all sliding or jointed parts of the overrun device Check on possible wear of the wheel brakes bearings brake lining yearly 6 2 3 Ion exchange resin filter DI changing resin bags Instructions Shut off...

Страница 18: ...no good filter results For this reason a special care agent must be filled in order to avoid this blocking 1 Disconnect the water supply if connected 2 Connect the concentrate hose so that excess wate...

Страница 19: ...bolts of the trailer and if necessary fasten the wheel bolts Follow the good torque moments see also technical data 8 4 Repeat this always when a wheel is loosened for example if a tyre is changed tig...

Страница 20: ...aks external damages and hair cracks If damaged or at leaks these must be immediately replaced 6 3 5 Electrical parts Check visible electric wiring and components on external visible damages If damage...

Страница 21: ...chanism defective Push the locking pin to open and replace if necessary Insufficient braking of trailer Excessive friction losses or corrosion on the drawbar Damage caused by impact during manoeuvring...

Страница 22: ...pump inlet outlet vlaves Leaks from pump head or switch For loose screws at switch or pump head Switch diagraphm ruptured or pinched For punctured diapgragm if fluid is present at bottom drain holes...

Страница 23: ...water temperature 4 C Maximum water temperature See technical data Sufficient water supply at drinking water quality Directive 98 83 EG Depending on the composition of the raw water the treated water...

Страница 24: ...11 Nm 25 Nm 36 Nm 43 Nm M 10 17 Nm 22 Nm 49 Nm 72 Nm 84 Nm M 12 29 Nm 39 Nm 85 Nm 125 Nm 145 Nm M 14 133 Nm 195 Nm 229 Nm M 16 206 Nm 302 Nm 354 Nm M 18 71 Nm 95 Nm 210 Nm 310 Nm 365 Nm M 20 138 Nm 18...

Страница 25: ...V DC 210A Gel battery OPERATING PRESSURE max 10 bar 150 psi WATER FLOW RATE max 250l h MAX WATER IN TEMPERATURE 4 C WATER OUT TEMPERATURE 30 C NOISE LEVEL 75 dB DIMENSIONS LxWxH 3500x1750x1600 mm WEIG...

Страница 26: ...3 28 83 188 4 8 4 PLACES 2 25 57 9 48 241 3 56 90 3 18 81 4 00 102 2 12 54 4 09 104 FILE 8030 813 239 REVISED 11 02 ISSUED 8 13 98 PumpAgents com buy pumps and parts online PumpAgents com Click here...

Страница 27: ...S THIS GRAPH IS FOR USE AS A DESIGN GUIDE IT IS BASED ON RUNNING CONTINUOUSLY WITH AN AMBIENT TEMPERATURE OF 75o F IN STILL AIR THE THERMAL BREAKER WILL OPEN WHEN THE CASE TEMPERATURE REACHES 205 o F...

Страница 28: ...hen be removed as ecologically sound as possible The possibilities those are open Exchange on a new machine Hand in at an waste treatment company Outside the E U you contact best the local government...

Страница 29: ...in charger in the vehicle or machinery The charger can be with fixed connection to the battery or with conventional connectors Position the charger in such a way that the air supply will not be obstr...

Страница 30: ...in Cable 1 6M full length 3 x 1 0 mm2 Protection IP 65 General Protected against wrong polarity and short circuit CE and Euronorms In accordance with the Low Voltage Directive 72 245 EEC and 2004 104...

Страница 31: ...www ungerglobal com 31 HydroPower RO XXL Notes ENGLISH...

Страница 32: ...rglobal com Unger UK Ltd F1 Deansgate 62 70 Tettenhall Road Wolverhampton WV1 4TH UNITED KINGDOM Fon 44 0 1902 306 633 Fax 44 0 1902 306 644 ungeruk ungerglobal com Unger Enterprises LLC 425 Asylum St...

Отзывы: