HydroPower® RO

Safety Information

2.3  Mandatory signs

Application tips and other useful information.

Use protective gloves.

Use safety shoes.

Use protective goggles.

Notes

_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________

Содержание HYDRO POWER RO20S

Страница 1: ...gerglobal com 1 OPERATING INSTRUCTIONS RO RO20S 22842 V1 0 1121 Operating Instructions READ THE OPERATING INSTRUCTIONS BEFORE TURNING ON THE SYSTEM KEEP OPERATING INSTRUCTIONS WITH THE MACHINE AT ALL...

Страница 2: ...ssure 9 2 9 Hazards from materials and substances 10 2 10 General hazards 11 2 10 1 Technical label 11 2 11 Responsibilities of the operator 12 2 12 Storing the operating instructions 13 2 13 Contact...

Страница 3: ...h the HydroPower RO 22 5 3 Interruption of work 22 5 4 Turning off the HydroPower RO 23 6 Troubleshooting 23 6 1 Procedures for troubleshooting 23 6 1 1 Water pressure too low 23 6 1 2 Overpressure 23...

Страница 4: ...y standards We support this with the Unger Professional Product Lifetime Guarantee We will replace your Unger HydroPower RO System if it does not meet our high quality standards for material construct...

Страница 5: ...ill tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed This is the safety alert symbol It is used to al...

Страница 6: ...ning of hot surfaces Warning of suspended loads Warning of injury to the limbs Notes _______________________________________________________ _______________________________________________________ ___...

Страница 7: ...__________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _____...

Страница 8: ...plete and legible condition Replace damaged or illegible labels Before cleaning or maintaining the HydroPower RO turn off the main power switch and disconnect it from all electricity sources Before pe...

Страница 9: ...shock and burns due to live parts Before each use perform a visual inspection of the power cable for damage If you notice any damage contact your distributor Maintenance on the electrical components...

Страница 10: ...s remove contact lenses and rinse eyes immediately and thoroughly with clean water Wash hands thoroughly after finishing work Wear protective gloves and goggles Spilled resin is a slipping hazard If r...

Страница 11: ...fabric of the building that may be dislodged Injury to others from falling poles caused by incorrect handling or failure of pole Injury through incorrect manual handling of poles and other equipment...

Страница 12: ...familiar with and strictly adhere to all applicable local state provincial and federal labor laws safety codes and standards The operator must have read and understood the HydroPower RO Operating Ins...

Страница 13: ...m the manufacturer These operating instructions can also be downloaded as a PDF at www ungerglobal com downloads NOTE When transferring or reselling the HydroPower RO to third parties the following do...

Страница 14: ...applies in particular to the use of the HydroPower RO for bacteria removal 3 2 Technical specifications 3 2 1 Operating conditions Ambient temperature F C 41 104 5 40 Water temperature F C 41 77 5 25...

Страница 15: ...content in incoming water mg l 20 3 3 Water output quantity The water flow depends on factors such as water temperature hose length and hose diameter Measuring Setup Hose length each 25m 82 2 differen...

Страница 16: ...mp ventilation slots 12 Pump Control 13 Power cord GFCI 14 Concentrate output connection concentrate hose The manometer shows the water pressure behind the pump Ensure that the water inlet pressure is...

Страница 17: ...ring transport cannot be accepted without written confirmation by the distributor In the case of transport of the HydroPower RO by a delivery vehicle DANGER Severe injuries and property damage due to...

Страница 18: ...ter enters the HydroPower RO via the water inlet 1 The carbon sediment combi pre filter 2 which filters out the largest impurities and chlorine from the water and thus protects the membranes sits befo...

Страница 19: ...ater inlet and water outlet hoses Connect the concentrate hose to the back of the unit see image 1 2 Connect the power cord to the power supply 3 Turn on the water supply 4 Turn upper switch to the WO...

Страница 20: ...the lower switch to OFF 3 Disconnect the water supply 4 Unscrew the resin housing and insert the resin filter catridge Make sure that the orientation is correct the blue filter inlet must be on top 5...

Страница 21: ...ng are possible Place the unit on a level surface only Make sure the unit is standing securely If necessary secure the wheels with a wedge before operating the system Wear safety shoes CAUTION Minor o...

Страница 22: ...OFF You can also control the unit by the water pressure The pump control switches off automatically after several seconds in case of negative pressure To start it again press the red RESTART button at...

Страница 23: ...er RO is now turned off and can be transported 6 Troubleshooting 6 1 Procedures for troubleshooting During operation the following may occur 6 1 1 Water pressure too low The water pressure from the in...

Страница 24: ...automatically stop 2 Turn OFF the system at the lower switch 3 Let the HydroPower RO cool down 4 Start the HydroPower RO with the lower switch e g PURE 5 If the pump does not start press the red REST...

Страница 25: ...ing operation Allow the system to cool down sufficiently before touching components marked with this symbol Wear protective gloves ATTENTION Damage caused by improper cleaning of the HydroPower RO is...

Страница 26: ...alue behind the resin filter running in PURE mode If this value is at or above 10 the resin filter must be replaced 7 2 2 Monthly inspection Check the performance of the membrane Turn to TAP BOOST mod...

Страница 27: ...ter and resin filter protected from dust and dirt 4 Insert the grey suction pipe into the left blue housing of the pre filter The holes must be on the bottom of the tube 5 Fill the pre filter housing...

Страница 28: ...rientation doesn t matter 4 Screw the housing into the unit and secure it with the filter key 3 The filter cartridge is now replaced 1 2 2 7 3 Repair and replacement of parts Additional information on...

Страница 29: ...the membrane out and replace with a new membrane The RO membrane has an imprint indicating the flow direction the arrow must point upward The rubber seal must always be at the bottom 7 Reassembly is t...

Страница 30: ...carried out by employees of Unger or authorized distributors technicians CAUTION Burns due to hot surfaces possible The housing of the pump motor can become hot during operation Allow the system to c...

Страница 31: ...ve the filters in the HydroPower RO where they are optimally protected against weathering To prepare the HydroPower RO for storage proceed as described in section 7 2 3 8 2 Recycling Properly recycle...

Страница 32: ...633 Fax 44 0 1902 306 644 ungeruk ungerglobal com Unger Enterprises LLC 425 Asylum Street Bridgeport CT 06610 UNITED STATES OF AMERICA Tel 1 800 431 2324 Fax 1 800 367 1988 unger ungerglobal com At U...

Отзывы: