HydroPower® RO
Startup
4.4 Startup
CAUTION
Minor or moderate injuries due to pressurized containers possible.
`
The three (3) filter housings are pressurized during operation.
`
Never open a housing or remove a hose during operation.
`
Check if the hoses and tubes are water-tight and fit properly before starting
up the system.
`
Wear protective gloves.
ATTENTION:
For new or used units, the resin filter is removed from the unit and must be
inserted! See section 4.4.1.
To start the HydroPower RO, proceed as follows:
1. Connect the water inlet and water outlet hoses. Connect the
concentrate hose to the back of the unit.
(see image 1)
2. Connect the power cord to the power supply.
3. Turn on the water supply.
4. Turn upper switch to the ”WORK” position.
(see image 4)
5. Turn the lower switch from ”OFF > PURE” to work with pure water.
(see image 5)
6. The pre-filter housing must fill completely with water before 100%
efficiency can be achieved.
(see image 6)
`
If pump does not start due to low pressure, press the RESTART
button located on the back of the unit.
The excess air escapes through the water and concentrate outlets.
(see image 6a)
3
The HydroPower RO is now ready for use.
When you select ”TAP BOOST”, unfiltered tap water with increased
pressure comes out to flush surfaces and remove stubborn dirt.