www.ungerglobal.com
www.ungerglobal.com
20
21
HydroPower® RO
Startup
2
4
5
1
4.4.1
Starting up a HydroPower RO:
The pre-filter and the resin filter are not inserted in new or used units, as they must not come into
contact with the membrane care liquid.
Before using the resin filter, the membrane care liquid must be completely rinsed out.
1. Open the water line and start the HydroPower RO by setting the upper
switch to “RO FLUSH” and the lower switch to “PURE”. Rinse out the
membrane care liquid for about 15 minutes.
2. Turn off the HydroPower RO: turn the lower switch to “OFF”.
3. Disconnect the water supply.
4. Unscrew the resin housing and insert the resin filter catridge. Make sure
that the orientation is correct, the blue filter inlet must be on top!
5. Screw the housing back on using the filter key.
6. Unscrew the pre-filter housing and insert the filter cartridge.
7. Screw the housing back on with help of the included filter key.
8. Start the HydroPower RO by setting the upper switch to “WORK” and the
lower switch to “PURE”.
3
The HydroPower RO is now ready for use.
4.5 Storage
If the unit is not used for more than 7 days, the membranes must be
protected in accordance with the storage instructions, (see section ”7.2.3
Membrane protection”). The HydroPower RO must be stored indoors.