8. Notifications and errors
8.1 Pul Fire
The message “
Pul Fire
” appears when the
themostove performs electronic cleaning
of the burning pot.
8.2 Stop Fire
The message “
Stop Fire
” appears in the
phase of stand by whent the thermostove
connected directly to the heating system
reaches the temperature setting
.
This mes-
sage appears also in the buffer tank mode
(configuration 4).
8.3 Wood
If the message “
Legn
” appears on the mo-
dels which are not BiFuel, contact your lo-
cal technical support.
8.4 Sic Off
The message “
Sic Off
” indicates water or
pellet security thermostat active. The boi-
ler/thermostove can go in over temperatu-
re if:
• Zoned heating system doesn’t have
an open zone to dissipate the produ-
ced heat;
• Circulation pump is blocked;
• Shut off valves are closed;
• If domestic hot water kit is installed
and the led “
Sun
” remains on.
To re-start the thermostove:
• Resolve the cause of over tempera-
ture;
• Remove the tap of the water and pel-
let security thermostats on the back
of the thermostove
(fig. 33)
;
• Push the thermostats buttons to di-
sable them;
• Proceed with the ignition.
Water
Pellet
fig. 33
- Security thermostats
8.5 Led “Sun”
When the led “
Sun
” blinks, it indicates that
domestic hot water kit is in use.
If the led “
Sun
” remains on:
• Press the button
SET
to see
UT01
on
the display
D1
.
• Press the button
SET
three times, on
the display
D1
will appear
UT04
.
• Press the button
2
until seeing “
09
”
on the display
D2
.
• Press
SET to confirm.
Содержание BiFuel en ELS34